中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Membrane affinity chromatography for analysis and purification of biopolymers

文献类型:期刊论文

作者Zhou, DM; Zou, HF; Ni, JY; Wang, HL; Yang, L; Zhang, YK
刊名chromatographia
出版日期1999-07-01
卷号50期号:1-2页码:27-34
关键词column liquid chromatography membrane stationary phase immunoaffinity analysis affinity efficiency adsorption capacity
英文摘要affinity columns suitable for hplc were prepared by immobilization of various ligands of protein a, human igg, human igm and pectinase on gma modified cellulose membrane. the adsorption capacity, affinity efficiency and activity recovery of various iggs on these affinity columns were measured. it was observed that the length of the coupling arm plays a very important role in affinity efficiency, and the effect of eluent flow-rate on adsorption capacity was very small. the protein a column was exploited for the process monitoring of dog igg in clinical experiments on immuno-adsorption therapy. a pectinase column was used for the determination of polygalacturonase inhibiting proteins first purified on a hydroxyapatite column. it took only about 2.5 min for analysis at a flow-rate of 1.0 ml min(-1). the high speed analysis of biopolymers could be performed at a flow rate of 6.0 ml min(-1) within 15 s. membrane affinity chromatography gives good reproducibility, high efficiency, low column-pressure and is rapid. it can also be used for micro-scale purification of biopolymers.
WOS标题词science & technology ; life sciences & biomedicine ; physical sciences
类目[WOS]biochemical research methods ; chemistry, analytical
研究领域[WOS]biochemistry & molecular biology ; chemistry
关键词[WOS]biomolecules ; performance ; proteins ; removal
收录类别SCI
语种英语
WOS记录号WOS:000081720200006
公开日期2015-11-10
源URL[http://159.226.238.44/handle/321008/138576]  
专题大连化学物理研究所_中国科学院大连化学物理研究所
作者单位Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&A Ctr, Dalian 116011, Peoples R China
推荐引用方式
GB/T 7714
Zhou, DM,Zou, HF,Ni, JY,et al. Membrane affinity chromatography for analysis and purification of biopolymers[J]. chromatographia,1999,50(1-2):27-34.
APA Zhou, DM,Zou, HF,Ni, JY,Wang, HL,Yang, L,&Zhang, YK.(1999).Membrane affinity chromatography for analysis and purification of biopolymers.chromatographia,50(1-2),27-34.
MLA Zhou, DM,et al."Membrane affinity chromatography for analysis and purification of biopolymers".chromatographia 50.1-2(1999):27-34.

入库方式: OAI收割

来源:大连化学物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。