Determination of fentanyl in human breath by solid-phase microextraction and gas chromatography-mass spectrometry
文献类型:期刊论文
作者 | Wang, Changsong1; Li, Enyou1; Xu, Guowang2; Wang, Hui1; Gong, Yulei1; Li, Peng1; Liu, Shujuan1; He, Ying1 |
刊名 | microchemical journal
![]() |
出版日期 | 2009-03-01 |
卷号 | 91期号:2页码:149-152 |
关键词 | Fentanyl Breath Solid-phase microextraction Gas chromatography-mass spectrometry |
英文摘要 | fentanyl, a kind of intravenous narcotic analgesic, is widely used in clinical anesthesia. as a potential pollution, it was detected in both the air of the cardiothoracic operating room and patients' expiratory circuit. however, whether the fentanyl in patients' expiratory circuit is exhaled by patients is unknown. in this study, breath samples were taken from the expiratory circuits of anesthetic machine linked to the patients who received intravenous fentanyl, a solid-phase microextraction (spme) coupled with gas chromatography-mass spectrometry (gc-ms) method was developed to detect and quantify fentanyl in breath samples. the parameters influencing adsorption (extraction time, temperature,) and desorption (desorption time) of the analyte on the fiber were investigated and validated for method development. the developed method was proved to be simple, easy, and inexpensive and offer high sensitivity and reproducibility. linear range was obtained from 0.05 ng/ml to 0.8 ng/ml. the limit of detection was 0.01 ng/ml while an interday precision of less than 12.13% (n = 5) could be achieved. six patients were involved in this study; results showed presence of fentanyl in the breath of patients who received intravenous fentanyl, and fentanyl concentrations in breath varied from 6.00 to 20.89 pg/ml. in conclusion, fentanyl can be exhaled by patients who received intravenous fentanyl. (c) 2008 elsevier b.v. all rights reserved. |
WOS标题词 | science & technology ; physical sciences |
类目[WOS] | chemistry, analytical |
研究领域[WOS] | chemistry |
关键词[WOS] | transdermal patches ; human plasma ; samples ; sufentanil ; urine |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000264238000001 |
公开日期 | 2015-11-17 |
源URL | [http://159.226.238.44/handle/321008/141397] ![]() |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
作者单位 | 1.Harbin Med Coll, Dept Anesthesiol, Affiliated Hosp 1, Harbin 150001, Heilongjiang, Peoples R China 2.Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&A Ctr, Dalian 116023, Liaoning, Peoples R China |
推荐引用方式 GB/T 7714 | Wang, Changsong,Li, Enyou,Xu, Guowang,et al. Determination of fentanyl in human breath by solid-phase microextraction and gas chromatography-mass spectrometry[J]. microchemical journal,2009,91(2):149-152. |
APA | Wang, Changsong.,Li, Enyou.,Xu, Guowang.,Wang, Hui.,Gong, Yulei.,...&He, Ying.(2009).Determination of fentanyl in human breath by solid-phase microextraction and gas chromatography-mass spectrometry.microchemical journal,91(2),149-152. |
MLA | Wang, Changsong,et al."Determination of fentanyl in human breath by solid-phase microextraction and gas chromatography-mass spectrometry".microchemical journal 91.2(2009):149-152. |
入库方式: OAI收割
来源:大连化学物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。