Simultaneous determination of maltose and glucose using a screen-printed electrode system
文献类型:期刊论文
| 作者 | Ge, F; Zhang, XE; Zhang, ZP; Zhang, XM |
| 刊名 | BIOSENSORS & BIOELECTRONICS
![]() |
| 出版日期 | 1998-03-01 |
| 卷号 | 13期号:3-4页码:333-339 |
| 关键词 | screen-printed electrode 1 cyclic voltammetry chronoamperometry sequence electrode 1 '-ferrocenedimethanol (FDM) |
| 英文摘要 | A screen-printed sensor system consisting of a glucose oxidase (GOD) electrode and an amyloglucosidase/glucose oxidase (A/G) electrode was constructed to determine maltose and glucose simultaneously in a mixture. Sensor construction was optimised so that it contained 20 units of GOD/40 units of amyloglucosidase and 0.2 mM 1,1'-ferrocenedimethanol. These components were deposited onto a screen-printed carbon electrode and an outer membrane was printed from 3.5% hydroxyethyl cellulose (HEC) solution. The optimum pH was 4.8. The linear range of the system was up to 40 mM glucose or 20 mmol/L maltose with coefficients of variation (CVs) ranging from 3.5% to 5.29%. The results obtained by using the enzyme electrode system agreed well with those obtained by the Fehling titration method. When stored dry, especially at 4 degrees C, the enzyme electrodes showed good stability over four months. (C) 1998 Elsevier Science S.A. |
| WOS标题词 | Science & Technology ; Life Sciences & Biomedicine ; Physical Sciences |
| 类目[WOS] | Biophysics ; Biotechnology & Applied Microbiology ; Chemistry, Analytical ; Electrochemistry ; Nanoscience & Nanotechnology |
| 研究领域[WOS] | Biophysics ; Biotechnology & Applied Microbiology ; Chemistry ; Electrochemistry ; Science & Technology - Other Topics |
| 关键词[WOS] | FLOW-INJECTION SYSTEM ; CARBON ELECTRODES ; DISPOSABLE BIOSENSORS ; REDUCED GLUTATHIONE ; ENZYME ELECTRODE ; SENSORS ; INK ; LACTATE ; PASTES |
| 收录类别 | SCI |
| 语种 | 英语 |
| WOS记录号 | WOS:000073925300008 |
| 公开日期 | 2015-12-01 |
| 源URL | [http://ir.wipm.ac.cn/handle/112942/8286] ![]() |
| 专题 | 武汉物理与数学研究所_2011年以前论文发表(包括2011年) |
| 作者单位 | Acad Sinica, Wuhan Inst Phys, Wuhan 430071, Peoples R China |
| 推荐引用方式 GB/T 7714 | Ge, F,Zhang, XE,Zhang, ZP,et al. Simultaneous determination of maltose and glucose using a screen-printed electrode system[J]. BIOSENSORS & BIOELECTRONICS,1998,13(3-4):333-339. |
| APA | Ge, F,Zhang, XE,Zhang, ZP,&Zhang, XM.(1998).Simultaneous determination of maltose and glucose using a screen-printed electrode system.BIOSENSORS & BIOELECTRONICS,13(3-4),333-339. |
| MLA | Ge, F,et al."Simultaneous determination of maltose and glucose using a screen-printed electrode system".BIOSENSORS & BIOELECTRONICS 13.3-4(1998):333-339. |