Fluorescence X-ray source used for calibrating the detector of X-ray navigation
文献类型:期刊论文
作者 | Dai Jin-Fei1,2; Zhao Bao-Sheng1![]() ![]() ![]() ![]() |
刊名 | acta physica sinica
![]() |
出版日期 | 2015-07-20 |
卷号 | 64期号:14页码:426-431 |
关键词 | X-ray pulsar navigation fluorescence X-ray source detector calibration |
其他题名 | 标定脉冲星导航探测器的荧光x射线光源 |
英文摘要 | lots of research work on the x-ray pulsar navigation detector has been carried out, but the rigorous quantitative calibration results of these detectors have never been given out. in order to further promote the research process in x-ray pulsar navigation field, a kind of high-precision x-ray source which could be tunable in energy distribution and photon flux is necessary. a new method has been proposed to generate such an x-ray source, in which a conventional x-ray tube which is called the original level tube is used to excite a special fluorescence target to generate fluorescence x-ray source. firstly, the primary experiment system is built, with which the intensity of the fluorescence x-ray source is measured in atmospheric environment. the result indicates that the fluorescence x-ray source can be implemented in vacuum system to calibrate the detectors. then an integral fluorescence x-ray source is fabricated which can be used in vacuum system and its intensity is measured under the condition of d-x = 300 cm and i-a = 200 mu a. the photo fluxes are obtained to be 19.57 phs/s at 4.51 kev, 25.22 phs/s at 5.41 kev, and 33.27 phs/s at 8.05 kev. these data demonstrate the correctness of our method and that this new fluorescence x-ray source can be used to calibrate the x-ray pulsar navigation detector. |
WOS标题词 | science & technology ; physical sciences |
类目[WOS] | physics, multidisciplinary |
研究领域[WOS] | physics |
收录类别 | SCI ; EI |
语种 | 中文 |
WOS记录号 | WOS:000362976400055 |
公开日期 | 2015-12-01 |
源URL | [http://ir.opt.ac.cn/handle/181661/25500] ![]() |
专题 | 西安光学精密机械研究所_光电子学研究室 |
作者单位 | 1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, State Key Lab Transent Opt & Photon, Xian 710119, Peoples R China 2.Univ Chinese Acad Sci, Beijing 100084, Peoples R China |
推荐引用方式 GB/T 7714 | Dai Jin-Fei,Zhao Bao-Sheng,Sheng Li-Zhi,et al. Fluorescence X-ray source used for calibrating the detector of X-ray navigation[J]. acta physica sinica,2015,64(14):426-431. |
APA | Dai Jin-Fei.,Zhao Bao-Sheng.,Sheng Li-Zhi.,Zhou Yan-Nan.,Chen Chen.,...&Li Lin-Sen.(2015).Fluorescence X-ray source used for calibrating the detector of X-ray navigation.acta physica sinica,64(14),426-431. |
MLA | Dai Jin-Fei,et al."Fluorescence X-ray source used for calibrating the detector of X-ray navigation".acta physica sinica 64.14(2015):426-431. |
入库方式: OAI收割
来源:西安光学精密机械研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。