中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Analysis the influence of pyramidal error on the encoder accuracy test by using coordinate transformation

文献类型:期刊论文

作者Tian, Liude; Liu, Chaohui; Zhao, Jianke; Duan, Yaxuan; Pan, Liang; Zhao, Huaixue; Long, Jiangbo; Zhou, Yan; Li, Kun
刊名guangxue xuebao/acta optica sinica
出版日期2015-05-10
卷号35期号:5
其他题名利用坐标变换分析塔差对编码器测角精度测试的影响
英文摘要in order to realize the high precision measurement of encoder accuracy, the principle and method to measure encoder accuracy by using polyhedron and autocollimator are introduced. the polyhedron coordinate system and autocollimator measurement coordinate system are established, and the precise mathematical model is established, which is relation with the measurement error of the encoder accuracy and pyramidal error. the simulation results show that the encoder shaft tilt angle and tilt direction will affect the measurement results of the encoder accuracy. measurement error of encoder accuracy increases with encoder shaft tilt angle, and approximately proportional to the square. measurement error of encoder accuracy changes with encoder shaft tilt direction. when encoder shaft tilt direction is 0° or 180°, measurement error is the smallest; when encoder shaft tilt direction is 90° or 270°, measurement error is the maximum. as encoder shaft tilt angle is 5′, the measurement errors can reach 0.11″~0.48″, which cannot be ignored for encoder with 1~3 levels of precision grade. pyramidal error should be cotrolled in the appropriate range based on the precision grade of measured encoder. specific requirements on pyramidal error are given for encoders with different precision grades. ©, 2015, chinese optical society. all right reserved.
收录类别EI
语种中文
公开日期2015-12-08
源URL[http://ir.opt.ac.cn/handle/181661/27313]  
专题西安光学精密机械研究所_检测技术研究中心
推荐引用方式
GB/T 7714
Tian, Liude,Liu, Chaohui,Zhao, Jianke,et al. Analysis the influence of pyramidal error on the encoder accuracy test by using coordinate transformation[J]. guangxue xuebao/acta optica sinica,2015,35(5).
APA Tian, Liude.,Liu, Chaohui.,Zhao, Jianke.,Duan, Yaxuan.,Pan, Liang.,...&Li, Kun.(2015).Analysis the influence of pyramidal error on the encoder accuracy test by using coordinate transformation.guangxue xuebao/acta optica sinica,35(5).
MLA Tian, Liude,et al."Analysis the influence of pyramidal error on the encoder accuracy test by using coordinate transformation".guangxue xuebao/acta optica sinica 35.5(2015).

入库方式: OAI收割

来源:西安光学精密机械研究所