The effects of different calibration and frequency response correction methods on eddy covariance ozone flux measured with a dry chemiluminescence analyzer

文献类型:SCI/SSCI论文

作者Zhu Z. L.; Zhao, F. H.; Voss, L.; Xu, L. K.; Sun, X. M.; Yu, G. R.; Meixner, F. X.
发表日期2015
关键词Ozone flux Eddy covariance Fast-response ozone analyzer Spectral analysis Frequency response correction Calibration methods laser absorption-spectroscopy path co2 analyzers water-vapor carbon-dioxide correlation systems surface fluxes sampling tubes gas analyzer exchange fluctuations
英文摘要Ozone (O-3) flux (F-o) was measured over a wheat field in Yucheng, China, using the eddy covariance technique. A dry chemiluminescence fast-response O-3 analyzer and a UV-absorption based slow-response O-3 analyzer were used for measuring fast O-3 concentration fluctuations and absolute concentrations, respectively. The main objective of this study was to determine a group of suitable methods for calculating F-o based on the performance of the two O-3 analyzers in the field. We evaluated the effects of three calibration methods on F-o. These calibration methods include the ratio method (RM, it assumes that the fast-response analyzer's signal-output is directly proportional to absolute ambient O-3 concentration within a 30-min interval), the ratio offset method (ROM, it is based on the ratio method with analyzer's offset modification), and the ratio variation method (RVM, it is based on the ratio method with the fast-response analyzer's gain factor variation within a 30-min interval). Three frequency response corrections (analytic, revised analytic, and in-situ) for the estimation of F-o were also evaluated. Our results show that: (1) Compared to the O-3 flux with the commonly-used method (RM), on average, the fluxes with ROM and RVM were decreased by about 9% and 7%, respectively. (2) Based on the spectral analysis, the fast-response 03 analyzer's noise could cause random errors, but did not result in a systematic error in F-o. Tubing attenuation in O-3 concentration fluctuations can cause up to 20% loss in F-o. (3) Frequency response corrections for F-o with the original analytic method, the in-situ method, and the revised analytic method were 34.6%, 23.8% and 25.4% on average, respectively. (C) 2015 Elsevier B.V. All rights reserved.
出处Agricultural and Forest Meteorology
213
114-125
收录类别SCI
语种英语
ISSN号0168-1923
源URL[http://ir.igsnrr.ac.cn/handle/311030/39097]  
专题地理科学与资源研究所_历年回溯文献
推荐引用方式
GB/T 7714
Zhu Z. L.,Zhao, F. H.,Voss, L.,et al. The effects of different calibration and frequency response correction methods on eddy covariance ozone flux measured with a dry chemiluminescence analyzer. 2015.