中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
热门
Determination of phthalate esters in environmental water by magnetic Zeolitic Imidazolate Framework-8 solid-phase extraction coupled with high-performance liquid chromatography

文献类型:期刊论文

作者Liu, Xiaomei1; Sun, Zhiwei1; Chen, Guang1; Zhang, Wanwan1; Cai, Yiping1; Kong, Rongmei1; Wang, Xiaoyan2; Suo, Yourui2; You, Jinmao1,2,3
刊名journal of chromatography a
出版日期2015-08-28
卷号1409页码:46-52
关键词Magnetic solid-phase extraction (MSPE) Zeolitic lmidazolate Framework-8 (ZIF-8) High-performance liquid chromatography (HPLC) Phthalate esters (PAEs)
中文摘要in this study, the magnetic zeolitic imidazolate framework-8 (zif-8) microspheres were successfully synthesized and applied as an effective sorbent for preconcentration of several typical phthalate esters (paes) from environmental water samples. firstly, the solvothermal treatment method was used for preparation of fe3o4 nanoparticles. then, mercaptoacetic acid (maa) was served as the functionalized chemical to modify fe3o4 nanoparticles. the fe3o4@zif-8 core-shell microspheres were synthesized through coating the maa-capped fe3o4 nanoparticles with zif-8. by coupling magnetic solid-phase extraction (mspe) with high-performance liquid chromatography (hplc), a reliable, sensitive and cost-effective method for simultaneous determination of five main paes including dimethyl phthalate (dmp), diethyl phthalate (dep), di-n-butyl phthalate (dbp), benzyl butyl phthalate (bbp), and dioctyl phthalate (dop) was developed. good linearity was observed in the range of 1.0-100.0 mu g/l. the limits of detection (s/n =3) and limits of quantification (s/n = 10) were in the range of 0.08-0.24 and 0.3-0.8 mu g/l, respectively. the relative standard deviations were less than 5.5% and the accuracies of the method for the paes were in the range from 85.6% to 103.6%. finally, the fe3o4@zif-8 was successfully applied for rapid extraction of trace amounts of paes in environmental water samples. (c) 2015 elsevier b.v. all rights reserved.
英文摘要in this study, the magnetic zeolitic imidazolate framework-8 (zif-8) microspheres were successfully synthesized and applied as an effective sorbent for preconcentration of several typical phthalate esters (paes) from environmental water samples. firstly, the solvothermal treatment method was used for preparation of fe3o4 nanoparticles. then, mercaptoacetic acid (maa) was served as the functionalized chemical to modify fe3o4 nanoparticles. the fe3o4@zif-8 core-shell microspheres were synthesized through coating the maa-capped fe3o4 nanoparticles with zif-8. by coupling magnetic solid-phase extraction (mspe) with high-performance liquid chromatography (hplc), a reliable, sensitive and cost-effective method for simultaneous determination of five main paes including dimethyl phthalate (dmp), diethyl phthalate (dep), di-n-butyl phthalate (dbp), benzyl butyl phthalate (bbp), and dioctyl phthalate (dop) was developed. good linearity was observed in the range of 1.0-100.0 mu g/l. the limits of detection (s/n =3) and limits of quantification (s/n = 10) were in the range of 0.08-0.24 and 0.3-0.8 mu g/l, respectively. the relative standard deviations were less than 5.5% and the accuracies of the method for the paes were in the range from 85.6% to 103.6%. finally, the fe3o4@zif-8 was successfully applied for rapid extraction of trace amounts of paes in environmental water samples. (c) 2015 elsevier b.v. all rights reserved.
WOS标题词science & technology ; life sciences & biomedicine ; physical sciences
类目[WOS]biochemical research methods ; chemistry, analytical
研究领域[WOS]biochemistry & molecular biology ; chemistry
关键词[WOS]polycyclic aromatic-hydrocarbons ; mass-spectrometry ; milk samples ; acid-esters ; ms analysis ; pore-walls ; microextraction ; nanoparticles ; microspheres ; enrichment
收录类别SCI
语种英语
WOS记录号WOS:000359882600005
源URL[http://ir.nwipb.ac.cn/handle/363003/5523]  
专题西北高原生物研究所_中国科学院西北高原生物研究所
作者单位1.Qufu Normal Univ, Key Lab Life Organ Anal Shandong Prov, Qufu 273165, Peoples R China
2.Chinese Acad Sci, Northwest Inst Plateau Biol, Xining, Peoples R China
3.Key Lab Pharmaceut Intermediates & Nat Prod, Qufu, Peoples R China
推荐引用方式
GB/T 7714
Liu, Xiaomei,Sun, Zhiwei,Chen, Guang,et al. Determination of phthalate esters in environmental water by magnetic Zeolitic Imidazolate Framework-8 solid-phase extraction coupled with high-performance liquid chromatography[J]. journal of chromatography a,2015,1409:46-52.
APA Liu, Xiaomei.,Sun, Zhiwei.,Chen, Guang.,Zhang, Wanwan.,Cai, Yiping.,...&You, Jinmao.(2015).Determination of phthalate esters in environmental water by magnetic Zeolitic Imidazolate Framework-8 solid-phase extraction coupled with high-performance liquid chromatography.journal of chromatography a,1409,46-52.
MLA Liu, Xiaomei,et al."Determination of phthalate esters in environmental water by magnetic Zeolitic Imidazolate Framework-8 solid-phase extraction coupled with high-performance liquid chromatography".journal of chromatography a 1409(2015):46-52.

入库方式: OAI收割

来源:西北高原生物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。