Terahertz wave asymmetric transmission based on double-layer subwavelength dielectric grating
期刊论文
OAI收割
Optical Engineering, 2019, 卷号: 58, 期号: 6, 页码: 6
作者:
J.Qiu
;
J.Xu
;
F.Fan
  |  
收藏
  |  
浏览/下载:23/0
  |  
提交时间:2020/08/24
Terahertz,asymmetric transmission,subwavelength dielectric grating,one-way transmission,light,slit,Optics
High power diode laser source with a transmission grating for two spectral beam combining
期刊论文
OAI收割
Optik, 2019, 卷号: 192, 页码: 4
作者:
J.Y.Tian
;
J.Zhang
;
H.Y.Peng
;
Y.X.Lei
;
L.Qin
  |  
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2020/08/24
Diode laser,Spectral beam combining,Transmission grating,High beam,quality,array,Optics
Advanced astigmatism-corrected tandem Wadsworth mounting for small-scale spectral broadband imaging spectrometer (EI CONFERENCE)
会议论文
OAI收割
作者:
Lin G.-Y.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
Tandem gratings of double-dispersion mount make it possible to design an imaging spectrometer for the weak light observation with high spatial resolution
high spectral resolution
and high optical transmission efficiency. The traditional tandem Wadsworth mounting is originally designed to match the coaxial telescope and large-scale imaging spectrometer. When it is used to connect the off-axis telescope such as off-axis parabolic mirror
it presents lower imaging quality than to connect the coaxial telescope. It may also introduce interference among the detector and the optical elements as it is applied to the short focal length and small-scale spectrometer in a close volume by satellite. An advanced tandem Wadsworth mounting has been investigated to deal with the situation. The Wadsworth astigmatism-corrected mounting condition for which is expressed as the distance between the second concave grating and the imaging plane is calculated. Then the optimum arrangement for the first plane grating and the second concave grating
which make the anterior Wadsworth condition fulfilling each wavelength
is analyzed by the geometric and first order differential calculation. These two arrangements comprise the advanced Wadsworth mounting condition. The spectral resolution has also been calculated by these conditions. An example designed by the optimum theory proves that the advanced tandem Wadsworth mounting performs excellently in spectral broadband. 2012 Optical Society of America.
Study on spectrograph for ionosphere: A broadband imaging instrument prototype for far-ultraviolet (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:
Wang S.-R.
;
Lin G.-Y.
;
Yu L.
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2013/03/25
Current research on space-based exploration for the ionosphere needs more advanced technologies. Because the spectral signals in the ionosphere distributing basically in the far-ultraviolet waveband are very weak. Usual spectrometer structures and detectors such as CCD can't receive enough information. Based on this principle of atmospheric sounding
the imaging spectrometer prototype for ionosphere detection application was designed to solve the problem. This prototype consists of the telescope and the imaging spectrometer. The simple structure and small number of mirrors can help higher transmission efficiency be achieved and weak signals detection be implemented. The telescope is an off-axis parabolic mirror and the spectrometer is a modified Czerny-Turner spectral imaging system. Modified Czerny-Turner spectrometer contains a spherical mirror
a fixed plane grating and a toroidal mirror. By adjusting the incident angle to the collimating mirror and using toroidal mirror
coma and astigmatism were corrected well. We also optimize distances between the grating to the focusing mirror and the focusing mirror to the image plane to improve disadvantages of traditional Czerny-Turner structure. Designed results demonstrate that aberrations are substantially corrected
and high image quality can be obtained in broad waveband. The photon counting Wedge-Strip-Anode detector with micro-channel planes as the receiving plane is accepted for the instrument prototype. The other photon counting 2-D detector responding well for weak light such as Cross-Delay line detector and MAMA detector can also be used for detection. The calibration and performances testing system is made of a vacuum system
a deuterium lamp
a monochrometer and the instrument prototype. Results obtained from the experiment show that the spectral resolution is 2.4 nm and the spatial resolution is 80 m. The other calibration experiments are running. The technology of the spectrometer prototype is important for the research and applications of ionosphere remote sensing. 2011 SPIE.
High-performance soft x-ray spectromicroscopy beamline at SSRF (EI CONFERENCE)
会议论文
OAI收割
作者:
Xue C.
;
Chen J.
;
Wang Y.
;
Wang Y.
;
Wang Y.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
The Shanghai Synchrotron Radiation Facility (SSRF) is the first third-generation synchrotron facility in China and operated at an electron energy of 3.5 GeV. One of the seven beamlines in the first construction phase is devoted to soft x-ray spectromicroscopy and is equipped with an elliptically polarized undulator light source
a plane grating monochromator
and a scanning transmission x-ray microscope end station. Initial results reveal the high performance of this beamline
with an energy resolving power estimated to be over 10 000 at the argon L-edge and a spatial resolution better than 30 nm. 2010 American Institute of Physics.