中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共12条,第1-10条 帮助

条数/页: 排序方式:
Embedded image grabber and processing system based on camera link (EI CONFERENCE) 会议论文  OAI收割
2012 World Automation Congress, WAC 2012, June 24, 2012 - June 28, 2012, Puerto Vallarta, Mexico
作者:  
Wang Z.;  Zhao Y.;  Zhao Y.;  Zhao Y.;  Wang Z.
收藏  |  浏览/下载:34/0  |  提交时间:2013/03/25
A glycine ligand coordinated hybrid complex constructed from hexanuclear copper clusters and octamolybdates 期刊论文  OAI收割
Inorganic Chemistry Communications, 2011, 卷号: 14, 期号: 9, 页码: 1546-1549
X. Y. Jiang; X. Y. Wu; R. M. Yu; D. Q. Yuan; W. Z. Chen
收藏  |  浏览/下载:37/0  |  提交时间:2012/06/06
Study on spectrograph for ionosphere: A broadband imaging instrument prototype for far-ultraviolet (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:  
Wang S.-R.;  Lin G.-Y.;  Yu L.
收藏  |  浏览/下载:36/0  |  提交时间:2013/03/25
Current research on space-based exploration for the ionosphere needs more advanced technologies. Because the spectral signals in the ionosphere distributing basically in the far-ultraviolet waveband are very weak. Usual spectrometer structures and detectors such as CCD can't receive enough information. Based on this principle of atmospheric sounding  the imaging spectrometer prototype for ionosphere detection application was designed to solve the problem. This prototype consists of the telescope and the imaging spectrometer. The simple structure and small number of mirrors can help higher transmission efficiency be achieved and weak signals detection be implemented. The telescope is an off-axis parabolic mirror and the spectrometer is a modified Czerny-Turner spectral imaging system. Modified Czerny-Turner spectrometer contains a spherical mirror  a fixed plane grating and a toroidal mirror. By adjusting the incident angle to the collimating mirror and using toroidal mirror  coma and astigmatism were corrected well. We also optimize distances between the grating to the focusing mirror and the focusing mirror to the image plane to improve disadvantages of traditional Czerny-Turner structure. Designed results demonstrate that aberrations are substantially corrected  and high image quality can be obtained in broad waveband. The photon counting Wedge-Strip-Anode detector with micro-channel planes as the receiving plane is accepted for the instrument prototype. The other photon counting 2-D detector responding well for weak light such as Cross-Delay line detector and MAMA detector can also be used for detection. The calibration and performances testing system is made of a vacuum system  a deuterium lamp  a monochrometer and the instrument prototype. Results obtained from the experiment show that the spectral resolution is 2.4 nm and the spatial resolution is 80 m. The other calibration experiments are running. The technology of the spectrometer prototype is important for the research and applications of ionosphere remote sensing. 2011 SPIE.  
Research on moving target tracking scene simulation technology under battlefield complicated environment based on Vega (EI CONFERENCE) 会议论文  OAI收割
4th International Congress on Image and Signal Processing, CISP 2011, October 15, 2011 - October 17, 2011, Shanghai, China
Wang S.; Wei Y.-J.
收藏  |  浏览/下载:15/0  |  提交时间:2013/03/25
In order to better simulate the real environment of the battlefield  which has moving-target and the complicated background and to simulate the tracking process of the target with 3d's simulation. This paper introduce a development platform of the Vega 3d simulation software  and how to use the Vega to simulate the complex battlefield background  which has the sky  the explosion effects in the ground  the fly parameters of fighter planes. It reappear a complete process  which contains capturing target and tracking target. Experiment indicate that the Vega development platform is convenient and fast  and can achieved the design parameters for the task's demands. It also has many advantages  that contains repeating the performance of real experiment and reducing the expenses of the military experiment. 2011 IEEE.  
The design of real-time monitoring the electromechanical actuator operation state based on the CANoe (EI CONFERENCE) 会议论文  OAI收割
2nd Annual Conference on Electrical and Control Engineering, ICECE 2011, September 16, 2011 - September 18, 2011, Yichang, China
作者:  
Zhang J.;  Wu D.;  Zhang J.;  Zhang J.
收藏  |  浏览/下载:19/0  |  提交时间:2013/03/25
Study on supper resolution reconstruction based on staggered arrays (EI CONFERENCE) 会议论文  OAI收割
2011 International Conference on Electronic and Mechanical Engineering and Information Technology, EMEIT 2011, August 12, 2011 - August 14, 2011, Harbin, China
Yuan Z.; Xing Z.; Guang J.
收藏  |  浏览/下载:24/0  |  提交时间:2013/03/25
The image resolution can be improved without increasing the requirement to optical imaging systems' parameters and decreasing the size of CCD pixel by staggered arrays technology  which arranges several CCDs in a specific mode. In this paper  an image super resolution method of improving the image resolution for 1.5 times both in two directions by 4 linear arrays staggered based on this technology is presented  which avoids the large computation in a single time by use of circulation method. This method is proved effective by the digital simulation  and a simulated experiment platform is constructed to test its feasibility. The image resolution is improved for 1.42 times of the unreconstructed image according to the imaging experiment of resolution chart  which is closed to 1.5 times in ideal case. And also  the reconstructed and unreconstructed images are evaluated by the image information entropy  which proves that the reconstructed image contains more information. 2011 IEEE.  
Preparation, characterization and optical properties of carbon doped ZnO nanocrystal (EI CONFERENCE) 会议论文  OAI收割
ICO20: Materials and Nanostructures, August 21, 2005 - August 26, 2005, Changchun, China
作者:  
Liu J.;  Liu J.;  Liu J.;  Li S.;  Wang Z.
收藏  |  浏览/下载:35/0  |  提交时间:2013/03/25
In this paper  we prepared carbon doped nanocrystalline ZnO by pyrolyzed zinc stearate at 250C and 300C respectively. The XRD curves indicate the sample has polycrystalline hexagonal wurtzite structure. The XRD data of the sample prepared at 250C and 300C has a bigger angle shift about 0.05and 0.3respectively. That indicate the structure of the sample has some changes. The EDS indicate the sample contains Zn  O and C. So the XRD shift may attribute to the C. The XPS indicate the C doped in the crystal lattice of ZnO of the sample prepared at 300C  and the sample prepared at 250C may be only a few of C doped in the crystal lattice of ZnO. The PL of the sample prepared at 300C only has a weak ultraviolet emission  which indicates C modified the nanocrystalline ZnO surface as a non-radiative recombination center. In this process C could non-radiatively recombine the carries on the nanocrystallin ZnO surface. The sample prepared at 250C has a strong visible emission at about 530 nm. This emission band could be attributed to oxygen vacancy because C schlepped some oxygen on the nanocrystalline ZnO surface.  
Compression of remote sensing image based on Listless Zerotree Coding and DPCM (EI CONFERENCE) 会议论文  OAI收割
ICO20: Remote Sensing and Infrared Devices and Systems, August 21, 2005 - August 26, 2005, Changchun, China
Chen S.-L.; Huang L.-Q.
收藏  |  浏览/下载:32/0  |  提交时间:2013/03/25
The data quantity of remote sensing image is very large. Furthermore  the lowest frequency subband contains the main energy of original image and reflects the coarse of original image after remote sensing image is transformed by wavelet  so it is very important to the reconstructed image. Therefore a hybrid image compression method based on Listless Zerotree Coding (LZC) and DPCM is presented  namely  the lowest frequency subband is compressed by DPCM and others are compressed by LZC. LZC is a kind of zerotree coding algorithm for hardware implementation  which is based on SPIHT and substitutes two significant bit maps for three lists in SPIHT algorithm. Thereby LZC significantly reduces the memory requirement and complexity during encoding and decoding procedure. But LZC doesn't recognize the significance of grandchild sets  so the PSNR values of LZC are lower than SPIHT's and the compression speed drops. It is improved by adding a significant bit map that recognizes the significance of grandchild sets. A comparison reveals that the PSNR results of the hybrid compression method are 2 dB higher than those of LZC  and the compression speed is also improved.  
The Simulation measurement experiment and calibration for Solar Total Irradiance Monitor on board (EI CONFERENCE) 会议论文  OAI收割
ICO20: Remote Sensing and Infrared Devices and Systems, August 21, 2005 - August 26, 2005, Changchun, China
Yupeng W.; Wei F.; Bingxi Y.
收藏  |  浏览/下载:37/0  |  提交时间:2013/03/25
STIM (Solar Total Irradiance Monitor) can be used on sun-synchronous polar orbit weather satellites to measure the total solar irradiance. It contains three independent and identical wide view absolute radiometers. They are mounted on the satellite in an angle which ensure the sun scan over the field of view of the absolute radiometers. This measurement method doesn't need the instrument tracking the sun but the sun scan over the field of view of the absolute radiometers in each orbit cycle. The paper presents the measurement method of simulation for solar irradiance measurement and calibration by mounting the instrument on a two-axis rotation table. By controlling the rotation angle velocity of the instrument in the meridian direction being the same as that of the weather satellite's on orbit  we can measure the solar irradiance when the sun scan over the field of view of the absolute radiometers to simulate the onboard state. And we have operated the measurement with the prototype of STIM. The SIAR-1 is traceable to WRR and serves as a transfer standard. So simultaneous comparison measurements between SIAR-1 and each of the three wide view absolute radiometers are measured to provide calibration corrections to the instrument. And we have a further study at the influence of stray light to the measurement results. This paper presents the method of simulation experiment and calibration for solar irradiance measurement with Solar Total Irradiance Monitor on board.  
Detection and tracking of low contrast targets based on integertype lifting wavelet transform (EI CONFERENCE) 会议论文  OAI收割
ICO20: Remote Sensing and Infrared Devices and Systems, August 21, 2005 - August 26, 2005, Changchun, China
作者:  
Wang L.;  Wang L.;  Wang Y.;  Wang Y.;  Wang Y.
收藏  |  浏览/下载:18/0  |  提交时间:2013/03/25
This paper presents a method for detecting and tracking of low contrast targets. The new method uses an integer-type lifting wavelet transform and the proposed method doesn't extract patterns similar to a template  but finds parts having the same feature in the targets. We utilize one of integer-type lifting wavelet transforms that contains rounding-off arithmetic for mapping integers to integers. The lifting term contains parameters that are learned by using standard training images of targets. We assume that the targets include many high frequency components. In order to obtain the features of the targets  the lifting parameters are determined by a condition that high frequency components are vanished in wavelet transform. But the condition cannot be determined by the parameters wholly. So  we put an additional condition of minimizing the squared sum of the lifting parameters. The advantage of using integer-type wavelet transform is simple and robust to noise. Simulation illustrated the approach can detect and track the moving targets in dim background. We would test our algorithm in the TV tracking system.