中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共11条,第1-10条 帮助

条数/页: 排序方式:
Shale Microstructure Prediction with Nonsmooth Sparse Regularizing X-Ray CT Imaging 期刊论文  OAI收割
NUMERICAL FUNCTIONAL ANALYSIS AND OPTIMIZATION, 2020, 页码: 11
作者:  
Ma, Qinghua;  Xu, Zuoliang;  Wang, Yanfei;  Wang, Yu;  Wang, Lihua
  |  收藏  |  浏览/下载:64/0  |  提交时间:2020/12/07
Joint shape and color descriptors for 3D urban model retrieval 期刊论文  OAI收割
INTERNATIONAL JOURNAL OF DIGITAL EARTH, 2016, 卷号: 9, 期号: 11, 页码: 1117-1134
作者:  
Zhang, Liang;  Zhang, Liqiang;  Yao, Xiaojing;  Mathiopoulos, P. Takis;  Han, Chunming
收藏  |  浏览/下载:37/0  |  提交时间:2017/04/24
Evaluation of the Chinese Fine Spatial Resolution Hyperspectral Satellite TianGong-1 in Urban Land-Cover Classification SCI/SSCI论文  OAI收割
2016
作者:  
Li X. K.;  Wu, T. X.;  Liu, K.;  Li, Y.;  Zhang, L. F.
  |  收藏  |  浏览/下载:39/0  |  提交时间:2017/11/09
Comparison and simulation of subpixel imaging modes for linear CCD (EI CONFERENCE) 会议论文  OAI收割
2012 3rd International Conference on Information Technology for Manufacturing Systems, ITMS 2012, September 8, 2012 - September 9, 2012, Qingdao, China
作者:  
Li Y.;  He B.;  Li Y.;  Li Y.;  Li Y.
收藏  |  浏览/下载:44/0  |  提交时间:2013/03/25
Subpixel technique of linear CCD is effective to enhance the spatial resolution without increasing the focal length of optics and reducing the pixel size. To compare image quality of two main subpixel imaging modes  quincunx sampling and four-point sampling  a method to quantitatively evaluate image quality of subpixel based on MTF was proposed. The MTF of quincunx and four-point sampling modes were derived. Analytical results shows that theoretical limiting resolution of quincunx sampling and four-point sampling is improved to 1.4 and 1.86 times respectively  and MTF values at Nyquist frequency of two modes are increased by 0.1106 and 0.1679  respectively. MTFA in (0  0.5) of two subpixel imaging modes were calculated and results illustrates that four-point sampling offers much more improvement with image quality than quincunx sampling  at the cost of double amount of data. A model for simulating subpixel imaging using Matlab was established  and simulation results of spoke target verify the theoretical analysis. (2012) Trans Tech Publications  Switzerland.  
Design of motion compensation mechanism of satellite remote sensing camera (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
Gu S.; Yan Y.; Xu K.; Jin G.
收藏  |  浏览/下载:49/0  |  提交时间:2013/03/25
With the development of aerospace remote sensing technology  the ground resolution of remote sensing camera enhances continuously. Since there is relative motion between camera and ground target when taking pictures  the target image recorded in recording media is moved and blurred. In order to enhance the imaging quality and resolution of the camera  the image motion had to be compensated. In order to abate the effect of image motion to image quality of space camera and improve the resolution of the camera  the compensation method of image motion to space camera is researched. First  the reason of producing drift angle and adjustment principle are analyzed in this paper. This paper introduce the composition and transmission principle of image motion compensation mechanism. Second  the system adopts 80C31 as controller of drift angle  and adopts stepping motor for actuators  and adopts absolute photoelectric encoder as the drift Angle measuring element. Then the control mathematical model of the image motion compensation mechanism are deduced  and it achieve the closed-loop control of the drift angle position. At the last  this paper analyses the transmission precision of the mechanism. Through the experiment  we measured the actual precision of the image motion compensation mechanism  and compared with the theoretical analysis. There are two major contributions in this paper. First  the traditional image motion compensation mechanism is big volume and quality heavy. This has not fit for the development trend of space camera miniaturization and lightweight. But if reduce the volume and quality of mechanism  it will bring adverse effects for the precision and stiffness of mechanism. For this problem  This paper designed a image motion compensation that have some advantages such as small size  light weight at the same time  high precision  stiffness and so on. This image motion compensation can be applicable to the small optics cameras with high resolution. Second  the traditional mechanism control need to corrected  fitting and iterative for the control formula of mechanism. Only in this way  we can get the optimal control mathematical model. This paper has high precision of the control formula derived. It can achieve the high precision control without fitting  It also simplify the difficulty of control mathematical model establishment. This paper designed the range of adjusting of image motion compensation mechanism between -5 +5. Based on choosing-5  -4  -3  -2  -1  0  +1  +2  +3  +4  +4 as the expectation value of the imaginary drift angle  we get ten groups of the fact data in adjusting drift angle measured. The test results show that the precision of the drift angle control system can be achieved in 1. It can meet the system requirements that the precision of the control system is less than 3'  and it can achieve the high-precision image motion compensation. 2011 SPIE.  
The new approach for infrared target tracking based on the particle filter algorithm (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:  
Sun H.;  Han H.-X.;  Sun H.
收藏  |  浏览/下载:63/0  |  提交时间:2013/03/25
Target tracking on the complex background in the infrared image sequence is hot research field. It provides the important basis in some fields such as video monitoring  precision  and video compression human-computer interaction. As a typical algorithms in the target tracking framework based on filtering and data connection  the particle filter with non-parameter estimation characteristic have ability to deal with nonlinear and non-Gaussian problems so it were widely used. There are various forms of density in the particle filter algorithm to make it valid when target occlusion occurred or recover tracking back from failure in track procedure  but in order to capture the change of the state space  it need a certain amount of particles to ensure samples is enough  and this number will increase in accompany with dimension and increase exponentially  this led to the increased amount of calculation is presented. In this paper particle filter algorithm and the Mean shift will be combined. Aiming at deficiencies of the classic mean shift Tracking algorithm easily trapped into local minima and Unable to get global optimal under the complex background. From these two perspectives that "adaptive multiple information fusion" and "with particle filter framework combining"  we expand the classic Mean Shift tracking framework.Based on the previous perspective  we proposed an improved Mean Shift infrared target tracking algorithm based on multiple information fusion. In the analysis of the infrared characteristics of target basis  Algorithm firstly extracted target gray and edge character and Proposed to guide the above two characteristics by the moving of the target information thus we can get new sports guide grayscale characteristics and motion guide border feature. Then proposes a new adaptive fusion mechanism  used these two new information adaptive to integrate into the Mean Shift tracking framework. Finally we designed a kind of automatic target model updating strategy to further improve tracking performance. Experimental results show that this algorithm can compensate shortcoming of the particle filter has too much computation  and can effectively overcome the fault that mean shift is easy to fall into local extreme value instead of global maximum value.Last because of the gray and fusion target motion information  this approach also inhibit interference from the background  ultimately improve the stability and the real-time of the target track. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).  
Image compression based on contourlet and no lists SPIHT (EI CONFERENCE) 会议论文  OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
作者:  
Zhang S.
收藏  |  浏览/下载:52/0  |  提交时间:2013/03/25
The volume of raw image data captured by the high resolution camera is extremely huge. Thus the efficient image compression method should be used to decrease the bit rate. The image compression method based on wavelet is used more widely nowadays. However  two dimensional wavelet is only the tensor product of the one dimensional wavelet whose support region of basis function is extended from interval to square. Contourlet is an image multiscale geometric analysis tool  which could represent image sparsely and has strong capability of nonlinear approximation. The basis function of contourlet is multidirectional and anisotropic. Nevertheless  contourlet is redundant. So the non-redundant Wavelet Based Contourlet Transform (WBCT) is used in this paper. The SPIHT algorithm is very efficient way to coding the significant coefficients. And the improved no lists SPIHT is more easy to implemented by hardware. Image compression method based on the combination of both wavelet based contourlet transform and no lists SPIHT coding is proposed in the paper. Experiment shows that compared to wavelet based scheme the contourlet scheme can reserve the texture of the image. For barbara test image when coding at low bit rate the PSNR can improve about 0.2dB. 2010 IEEE.  
Gimbal displacement error analysis on an electro-optical seeker (EI CONFERENCE) 会议论文  OAI收割
Optical Design and Testing IV, October 18, 2010 - October 20, 2010, Beijing, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:38/0  |  提交时间:2013/03/25
It is essential to analyze the gimbal displacement errors for a seeker due to the importance for cueing of targets and tracking for the final approach. Otherwise  for a seeker electro-driven with a concentric glass dome  the large errors will decrease the picking  pointing  and tracking precision rooted from the displacement errors existing between the rotation center of the optical system and the gimbal. And the gimbaled camera system displacement errors are never eliminated but reduced due to the geometric errors consists of geometric tolerances of gimbal structure  manufacture  installation and vibration coming from working environment. In this paper  the gimbal displacement errors in an electro-optically stabilized platform resulting from geometric errors and environment errors were analyzed and shown in detail. The mathematical modal of the gimbal displacement errors created based on multi-body dynamics demonstrated the connection between the gimbal displacement errors and the stabilized platform. Taking a visible light image seeker as a case  the diameter is 120mm  and the geometric tolerances came from the values of primary design and the vibration data came from the environmental vibration test on the pitch-yaw seeker  and at the same time  the errors resulting from installation were considered too. Based on calculating  the maximum gimbal displacement error will reach to 0.2mm for pitching angle smaller than 40 and yawing angle smaller than 60. However  the critical parts have been found out according to the probability theory and the reliability analysis successfully used in the paper  and finally  the maximum gimbal displacement error reduced to 0.1mm  which is acceptable corresponding to the picking  pointing and tracking precision for an optical imaging seeker. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Research on the laboratory radiometric calibration of the thermal imager (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Wang J.;  Liu Y.;  Liu Y.;  Liu Y.;  Sun Q.
收藏  |  浏览/下载:30/0  |  提交时间:2013/03/25
The radiometric calibration of the thermal imager was investigated to build the relationship between the input radiance and the digital output to realize the temperature measurement. The radiometric calibration was implemented in the State Key Laboratory of Applied Optics. A standard black body source was served as radiation source. The response of the thermal imager to the input radiance was tested for different gains. The experimental results show that the average grey level of the output imaging is linear dependence of the input radiance. Because the radiance in the receiving wave range of the thermal imager is linear with the black body's temperature based on Planck's law of radiation  the average grey level of the output image is also linear with the black body's temperature after fitting a curve to the experiment data points. Then the relationship of the response and the gain was studied when the black body's temperature kept constant. The preliminary analysis of calibration data shows that the response of the thermal imager is linear and the average grey value of the image is directly proportion to the gain. According to the experimental results  the reference gains and the dynamic range of temperature measurement were obtained. Finally  the uncertainty influencing the calibration results was analyzed  the analysis shows the maximal uncertainty is 5.2%  which can meet the calibration requirement less than 10%. 2010 Copyright SPIE - The International Society for Optical Engineering.  
A high-speed acquisition and processing system of the laser speckle signal on the magnetic fluid (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
作者:  
Sun Y.;  Sun Y.;  Wan Q.-H.
收藏  |  浏览/下载:29/0  |  提交时间:2013/03/25
In order to achieve the dynamical detection and real-time analysis of the movement status of the magnetic fluid  according to the difficulties of the detection of the magnetic fluid  established a high-speed acquisition and processing system of laser speckle signal on the magnetic fluid. First of all  the FPGA (EP2C8T144C8N) drived the linear array CCD(TCD1501D) to scan in the corresponding time sequence given by the computer  collected the laser speckle interferometric image in rapid change on the surface of the magnetic fluid  which followed the movement of the magnetic fluid  and the signal collected by CCD was converted into the digital data through the high-speed A/D convertor and stored into the internal buffer FIFO of the FPGA  whose width and depth were designed by the user as required. Then  the FPGA sent the digital signal of the laser speckle interferometric images into the computer through the USB2.0 highspeed differential bus  whose transmission rate can reach 480Mb/s in theory. Finally  the distribution of the laser speckle on the magnetic fluid was messy and random  which carried certain information about the surface of the magnetic fluid  based on the theories of the statistic correlation and the subdivision of images  analysing and processing the laser speckle interferometric images  indirectly got the movement status of the magnetic fluid under the electromagnetic field. The experimental results show that: the High Speed Acquisition and Processing System has the advantage of full-court  non-contact  non-invasive  high-precision and high reliability and so on. The detection resolution of high speed acquisition and processing system is superior to 1m and the sample rate is 3Msps  which basically meets the requirements of the magnetic fluid movement state detection. 2009 SPIE.