Design and relative calibration of a beam profile measurement system for the SC200 superconducting cyclotron
期刊论文
OAI收割
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 卷号: 989
作者:
Hu, Lexing
;
Ding, Kaizhong
;
Song, Yuntao
;
Wu, Yucheng
;
Yao, Kai
  |  
收藏
  |  
浏览/下载:37/0
  |  
提交时间:2021/04/26
Transverse beam profile
Scintillation screen
Beam diagnosis
Design and calibration
Commissioning
Compact cyclotron
Construction and simulation bias study of the guide Tube Calibration System for JUNO
期刊论文
OAI收割
JOURNAL OF INSTRUMENTATION, 2021, 卷号: 16, 期号: 7
作者:
Guo, YH
;
Zhu, KF
;
Zhang, QM
;
Zhang, FY
;
Meng, Y
  |  
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2023/03/27
Overall mechanics design (support structures and materials
vibration analysis etc)
Detector design and construction technologies and materials
Detector alignment and calibration methods (lasers
sources
particle-beams)
Detector control systems (detector and experiment mon-itoring and slow-control systems
architecture
hardware
algorithms
databases)
Reagentless near-infrared determination of cholesterol in undiluted human serum using interval partial least square (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Smart Materials and Nanotechnology in Engineering, SMNE 2011, September 17, 2011 - September 18, 2011, Wuhan, China
Gao H.
;
Lu Q.
;
Huang F.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
In order to determination of cholesterol in human serum with no reagent using nearinfrared (NIR) spectroscopy. Interval partial least square (iPLS) was proposed as an effective variable selection approach for multivariate calibration. For this purpose
an independent sample set was employed to evaluate the prediction ability of the resulting model. The spectrum was split into different interval. Then
the informative region of cholesterol (1688-1760nm)
in which the PLS model has a low RMSEP with 0.241mmol/L and a high R with 0.975
is selected with 23 intervals. The results indicate that
the informative region of cholesterol can be obtained by iPLS and applied to design the simpler reagentless NIR instruments for inexpensive cholesterol measurement in future. (2012) Trans Tech Publications
Switzerland.
Design and calibration of the solar irradiance monitor (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:
Yang D.-J.
;
Gong C.-H.
;
Wang Y.-P.
;
Ye X.
;
Fang W.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
The solar irradiance monitor (SIM)
with the design accuracy of 5
used to monitor the secular changes of the total solar irradiance on FY-3 satellite
takes the sun-scanning measurement method on-orbit. Compared to the sun-tracking measurement method
this method simplifies the structure and cuts the cost
but the measuring accuracy is affected by the sun-synchronous orbit
sunlight incidence angle and the installing angle of the SIM in the satellite. Through the ground calibration experiment
studies on the affection of different sunlight incidence angles to the measurement accuracy. First
by the satellite tool kit (STK) simulation software
simulates the orbital parameters of the sun-synchronous satellite
and calculates the Sun ascension and declination at any time. By the orbit coordinate transformation matrix gets the components of the Sun vectors to the axes of the satellite
and base on the components designs the field of view and the installing angles of the SIM. Then
designs and completes the calibration experiment to calibrate the affection of the incidence angles. Selecting 11 different angles between the sunlight and the satellite X-axis
measures the total solar irradiance by the SIM at each angle
and compares to the irradiances of the SIAR reference radiometers
and gets the coefficient curves of the three channels of the SIM. Finally
by the quadratic fitting
gets the correction equations on the incidence angles: R 1=5.7110-52 -2.45310 -3+1.0302
R2=2.8410-5-1. 96510-3+1.0314 and R3 =1.7210 -52-4.18410-4+0.9946. The equations will aimprove the on-orbit measurement accuracy of the solar irradiance
and are very important to the on-orbit data processing after the satellite launched. 2011 SPIE.
The study of encoding principle and encoding disc design of a new-style vernier absolute encoder (EI CONFERENCE)
会议论文
OAI收割
2nd Annual Conference on Electrical and Control Engineering, ICECE 2011, September 16, 2011 - September 18, 2011, Yichang, China
作者:
Li L.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
To satisfy the requirement of encoder miniaturization
high dependability
and high measuring accuracy
a new-style vernier absolute type encoder which offered significant advantages over less reticling circles and high precision was presented in the paper
which carried out the design of vernier encoding disc
the analysis of new-style vernier encoding principle
and exact encoding track calibration by studying the photoelectric encoder. The Matlab simulation results prove that the encoding and coding methods are feasible. The test showed that the cubage of encoder was quite small and the diameter of the encoder can be controlled within 100mm
its resolution can reach 24 bits i.e. 0.0772. The feasibility of encoding and coding method was further proved. 2011 IEEE.
Development and radiance calibration of three-waveband camera (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photonics and Optoelectronics, SOPO 2010, June 19, 2010 - June 21, 2010, Chengdu, China
作者:
Wang J.
;
Liu Y.
;
Liu Y.
;
Sun Q.
;
Liu Y.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
An imaging system with three-waveband sharing one lens and an area CCD was developed. By rotating different filters into the beam path
the required waveband was selected. The optical system which can image in ultraviolet
visible and near infrared region was designed and the signal collecting system was integrated. The optical design and system integration have some advantages such as low cost
small size and light in weight. To obtain a high imaging quality
the radiation calibration is carried out in order to establish the relation between the average grey level of output image and the input radiance from the integrating sphere. According to the calibration data in experiments
the radiation dynamic range and the best working point of the system are determined. The experiment result shows that the dynamic range of the image system is maximal when the exposure time is 8ms in ultraviolet
0.5ms in visible and 0.125ms in near infrared region. 2010 IEEE.
Narcissus analysis for cooled staring IR system (EI CONFERENCE)
会议论文
OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Advanced Optical Manufacturing Technologies, July 8, 2007 - July 12, 2007, Chengdu, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
Narcissus can have a deleterious effect on image quality for cooled infrared imaging systems. Therefore
analysis of narcissus is important for designing both scanning and staring optics. Narcissus is generally assumed to be negligible in staring IR optical designs because the shading effects can be removed by calibration of the detector array data. However
the calibration usually decreases sensitiveness of the system and Narcissus variation may be noticeable for sensors when the conditions changes as follows: 1. warming and cooling the optical housing
2. zooming optical elements
3. movement of lenses for focus. In that case
it will result in shading and other image defects even after calibration. To minimize these effects
narcissus should be assessed and controlled during the design of staring array IR system. We provided a direct and fast method for analyzing the narcissus variation in the presence of software such as LightTools
TracePro and ASAP
and proposed the principles in optical design of staring IR systems to reduce narcissus. A cooled staring IR system with serious narcissus was estimated and reoptimized. Narcissus analysis of this IR system confirmed the efficiency of the analysis method.
Chip design of linear CCD drive pulse generator and control interface (EI CONFERENCE)
会议论文
OAI收割
2nd International Symposium on Advanced Optical Manufacturing and Testing Technologies - Advanced Optical Manufacturing and Testing Technologies, November 2, 2005 - November 5, 2005, Xian, China
作者:
Sun H.
;
Wang Y.
;
Wang Y.
;
Wang Y.
;
Wang Y.
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/03/25
CCD noises and their causes are analyzed. Methods to control these noises
such as Correlated Double Sampling (CDS)
filtering
cooling
clamping
and calibration are proposed. To improve CCD sensor's performances
the IC
called Analog Front End (AFE)
integration of CDS
clamping
Programmable Gain Amplifier (PGA)
offset
and ADC
which can fulfill the CDS and analog-to-digital conversion
is employed to process the output signal of CCD. Based on the noise control approaches
the idea of chip design of linear CCD drive pulse generator and control interface is introduced. The chip designed is playing the role of (1) drive pulse generator
for both CCD and AFE
and (2) interface
helping to analysis and transfer control command and status information between MCU controller and drive pulse generator
or between global control unit in the chip and CCD/AFE. There are 6 function blocks in the chip designed
such as clock generator for CCD and AFE
MCU interface
AFE serial interface
output interface
CCD antiblooming parameter register and global control logic unit. These functions are implemented in a CPLD chip
Xilinx XC2C256-6-VQ100
with 20MHz pixel frequency
and 16-bit high resolution. This chip with the AFE can eliminate CCD noise largely and improve the SNR of CCD camera. At last
the design result is presented.