中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [4]
地理科学与资源研究所 [1]
采集方式
OAI收割 [5]
内容类型
会议论文 [5]
发表日期
2012 [1]
2011 [1]
2010 [1]
2007 [1]
2005 [1]
学科主题
筛选
浏览/检索结果:
共5条,第1-5条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
作者升序
作者降序
Design and application of natural audio electric field frequency selecting instrument
会议论文
OAI收割
3rd International Conference on Precision Instrumentation and Measurement 2011, CPIM2011, Xiangtan, China, July 18, 2011 - July 21, 2011
Liao, Xiuying(廖秀英)
;
Cheng, Hui
;
Bai, Yicheng
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2012/05/18
Groundwater resources
Instruments
Measurements
Mineral resources
Software design
System stability
Design and application
Electric field frequency
Electrical structures
Field works
Geological bodies
Geological information
Hardware design
Magnetotelluric soundings
Observe system
Weak signal detection
The sequence measurement system of the IR camera (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:
Zhang H.-B.
;
Han H.-X.
;
Geng A.-H.
收藏
  |  
浏览/下载:41/0
  |  
提交时间:2013/03/25
Currently
the IR cameras are broadly used in the optic-electronic tracking
optic-electronic measuring
fire control and optic-electronic countermeasure field
but the output sequence of the most presently applied IR cameras in the project is complex and the giving sequence documents from the leave factory are not detailed. Aiming at the requirement that the continuous image transmission and image procession system need the detailed sequence of the IR cameras
the sequence measurement system of the IR camera is designed
and the detailed sequence measurement way of the applied IR camera is carried out. The FPGA programming combined with the SignalTap online observation way has been applied in the sequence measurement system
and the precise sequence of the IR camera's output signal has been achieved
the detailed document of the IR camera has been supplied to the continuous image transmission system
image processing system and etc. The sequence measurement system of the IR camera includes CameraLink input interface part
LVDS input interface part
FPGA part
CameraLink output interface part and etc
thereinto the FPGA part is the key composed part in the sequence measurement system. Both the video signal of the CmaeraLink style and the video signal of LVDS style can be accepted by the sequence measurement system
and because the image processing card and image memory card always use the CameraLink interface as its input interface style
the output signal style of the sequence measurement system has been designed into CameraLink interface. The sequence measurement system does the IR camera's sequence measurement work and meanwhile does the interface transmission work to some cameras. Inside the FPGA of the sequence measurement system
the sequence measurement program
the pixel clock modification
the SignalTap file configuration and the SignalTap online observation has been integrated to realize the precise measurement to the IR camera. Te sequence measurement program written by the verilog language combining the SignalTap tool on line observation can count the line numbers in one frame
pixel numbers in one line and meanwhile account the line offset and row offset of the image. Aiming at the complex sequence of the IR camera's output signal
the sequence measurement system of the IR camera accurately measures the sequence of the project applied camera
supplies the detailed sequence document to the continuous system such as image processing system and image transmission system and gives out the concrete parameters of the fval
lval
pixclk
line offset and row offset. The experiment shows that the sequence measurement system of the IR camera can get the precise sequence measurement result and works stably
laying foundation for the continuous system. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Adaptive resolution storage system based on LOG-POLAR transform for multi-target trackers (EI CONFERENCE)
会议论文
OAI收割
2010 International Conference on Computer Application and System Modeling, ICCASM 2010, October 22, 2010 - October 24, 2010, Shanxi, Taiyuan, China
作者:
Zhang Y.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
The main constrained problem of the video monitoring and storage system is the contradiction between large field of view and storage space limitations. Not all of the video information introduced by the image sensors need to be recorded especially for some tracking system which has appointed functions to track specifically kinds of targets. For instance
the system not only works for single target
if the monitor is appointed for human face tracking
but also can work for multi-targets. High reconstruction resolution in the fovea region enables the successive application of recognition modules without sacrificing their performance
the best system appears to be concentrating on human face only and all the others considered being background
the low reconstruction resolution in the periphery helps to reduce the video data. 2010 IEEE.
the background regions needn't to be recorded in detail. For this purpose
this letter presents a real-time foveate storage system
which efficiently represents the video image in log-polar coordinates
with the foveate point centered on the target
Data preprocessing of the exterior field of vision assembling photogrammetric camera (EI CONFERENCE)
会议论文
OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, July 8, 2007 - July 12, 2007, Chengdu, China
作者:
Li J.
;
Li J.
;
Li J.
;
Liu J.
;
Liu J.
收藏
  |  
浏览/下载:84/0
  |  
提交时间:2013/03/25
Transmit array photogrammetric camera can obtain image which is high geometric fidelity and high photogrammetric quality. However
the single chip array CCD image sensor camera can't meet the need of measuring precision and photogrammetric covering area. In order to obtain large numbers of information and extensive photogrammetric covering area
we must increase field of vision angle and improve photogrammetric covering area. And all these objects can be realized by exterior field of vision assembling photogrammetric camera. Two side work must be done before images
which obtained by exterior field of vision assembling photogrammetric camera
be used in photogrammetry. First
all assembling camera focal plane need be converted to a benchmark coordinate focal plane to realize camera digital assembling. Second
images must be re-sampled and processing. Because of coordinate conversion
two images from different assembling cameras can be established function relation
which a pixel of image from a camera is corresponding to a pixel of another image from different camera. But through this conversion
some pixels maybe extrusion together and other pixels separate on an image area. So interpolation direction finding(IDF) is used to obtain these pixels and realize image re-sampling. In this paper
the structure of exterior field of vision assembling photogrammetric camera is analyzed
and the coordinate conversion method of exterior field of vision assembling photogrammetric camera and image gray re-sampling method also can be discussed. All the works are based to data pretreatment of exterior vision assembling photogrammetric camera.
Fabrication and electron emission of carbon microtubes (EI CONFERENCE)
会议论文
OAI收割
Technical Digest of the 18th International Vacuum Nanoelectronics Conference, IVNC 2005, July 10, 2005 - July 14, 2005, Oxford, United kingdom
作者:
Liu L.
;
Liu L.
;
Wang W.
;
Wang W.
收藏
  |  
浏览/下载:46/0
  |  
提交时间:2013/03/25
Carbon nanotubes have been attracting attention because of their unique physical properties and their application potential for field emission cathode. Carbon nanotubes possess the following properties favorable for field emission material
such as a high aspect ratio and sharp tip
high chemical stability
high mechanical strength
stable at high temperature. Some research works on carbon nanotubes field emitter and field emission display have been reported. Here
a kind of carbon microtubes and its field emission properties are introduced. They have some different properties with carbon nanotubes
and the density is lower than carbon nanotubes bundles. These carbon microtubes are directly synthesized by liquidoid epitaxy method on silicon substrates at low temperature. The field emission properties of carbon microtubes are reported too. Carbon microtubes film is synthesized in liquid by electrolysis. The graphite plate is as anode
and n-silicon substrate with resistivity of 4-8 cm is as cathode. The electrolysis current is about 5-8mA/cm2
and applied voltage is 800-1500V. Temperatures of the methanol base solution is maintained at 60C in process of deposition of carbon microtubes. Carbon microtubes film is observed by scanning electron microscopy(SEM)
as shown in fig.1(a
b). The wall's thickness of carbon microtube is about 60nm. The diameter of carbon microtube is about 0.8 m. Raman spectrum of carbon microtubes film shows the two peaks at 1342and 1560cm-1. The field emission properties of carbon microtubes are measured in high vacuum chamber(10-5Pa). The emission area of carbon microtubes is 0.5cm 0.5cm. The threshold of field emission of the carbon microtubes film is about 3.6V/ m. Field emission property of carbon microtubes film is shown in fig.2. Another
when the electric field between anode and cathode is 10V/ m
the electric field distribution on single carbon microtube is also given after calculation according to electric field theory. Fig 3 shows that electric field distribution vertical section on the of single carbon microtube top with 2 m of highness. These results may help us to understand field emission properties of carbon microtubes. According to research results
it is found that liquidoid synthesis is simple method to produce carbon microtubes cold cathode material
and the carbon microtubes have better field emission properties. 2005 IEEE.