中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共7条,第1-7条 帮助

条数/页: 排序方式:
Application of the DRS4 chip for GHz waveform digitizing circuits 期刊论文  OAI收割
CHINESE PHYSICS C, 2015, 卷号: 39
作者:  
Cheng Ke;  Chen Jin-Da;  Du Cheng-Ming;  Zhang Jing-Zhe;  Yang Hai-Bo
  |  收藏  |  浏览/下载:40/0  |  提交时间:2018/07/05
Analyse the angular velocity estimation errors of -- filter based on high sampling rate (EI CONFERENCE) 会议论文  OAI收割
2011 2nd International Conference on Mechanic Automation and Control Engineering, MACE 2011, July 15, 2011 - July 17, 2011, Inner Mongolia, China
作者:  
Zhang Y.
收藏  |  浏览/下载:31/0  |  提交时间:2013/03/25
In order to get angular velocity of stabilization servo mechanism from angular position sensors  -- filter based on high sampling rate was established  model and error characteristics were analyzed. With the hypothesis of constant acceleration  -- filter and its angular velocity transfer function were deduced. Combing with optimum parameters  the effects of and sample rate on the error characteristics were evaluated. According to the requirements of stabilization servo mechanism  the frequency characteristics of angular velocity transfer function are analyzed  and the filter parameters are designed. The experimental which filter tracked and smoothed sinusoidal signal  the results show that when the cutoff frequency of angular velocity loop is 44.9rad/s  sampling period and parameters are 0.08ms and 0.01279 respectively  the phase leading of angular position is 70. -- filter tracked sinusoidal signals with maximum angular velocity(30/s) and maximum angular acceleration(30/s2)  the error of angular velocity estimation was 0.053/s. In the engineering of electro-optical stabilization servo mechanism  -- filter can reduce noise effectively  and reached the requirement of platform angular velocity estimation. Also it is one of the effective methods to get angular velocity from angular position sensors. 2011 IEEE.  
The angular velocity estimation principal of -- filter based on high sampling rate (EI CONFERENCE) 会议论文  OAI收割
2011 2nd International Conference on Mechanic Automation and Control Engineering, MACE 2011, July 15, 2011 - July 17, 2011, Inner Mongolia, China
作者:  
Zhang Y.
收藏  |  浏览/下载:33/0  |  提交时间:2013/03/25
In order to get angular velocity of stabilization servo mechanism from angular position sensors  -- filter and its angular velocity transfer function were predigested. Combing with optimum parameters  -- filter based on high sampling rate was established  the effect of and sample rate on filter nature frequency were evaluated. According to the requirements of stabilization platform  the principle of steady and transient tracking filter differential were proved. With the hypothesis of constant acceleration  the frequency characteristics of angular velocity transfer function were analyzed  three-dimensional Kalman filter was simplified  and the filter parameters were designed. The results show that when the spectrum of input signal was lower than 6rad/s  parameters was 0.02  and sampling period were 0.08ms and 0.1ms respectively  the filter can realize differential exactly  when the spectrum was 9rad/s  the precision was no less than 1.1%  the phase leading of angular position was no less than 70  the natural frequency should be higher than the cut-off frequency of stabilization platform was two or three times. In the engineering of electro-optical stabilization servo mechanism  -- filter has properties of tracking differential  and reached the requirement of platform angular velocity estimation. Also it is one of the effective methods to get angular velocity from angular position sensors. 2011 IEEE.  
Identifying High-Rate Flows Based on Sequential Sampling 期刊论文  OAI收割
IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2010, 卷号: E93D, 期号: 5, 页码: 1162-1174
作者:  
Zhang, Yu;  Fang, Binxing;  Luo, Hao
  |  收藏  |  浏览/下载:25/0  |  提交时间:2019/12/16
Design of driving circuit for binocular CCD image system (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optoelectronic Materials and Devices for Detector, Imager, Display, and Energy Conversion Technology, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:45/0  |  提交时间:2013/03/25
The paper designs a driving circuit of high sensitive  wide dynamic and high signal-to-noise ratio for binocular CCD imaging system which adopts a Dalsa-made high resolution full-frame 33-mega pixels area CCD FTF5066M. Inner structure and driving timing of the FTF5066M sensor are presented. Field Programmable Gate Array (FPGA) is used as the main device to accomplish the timing design of the circuits and power driver control of the two sensors. By using the Correlated Double Sampling (CDS) technique  the video noise is reduced and the SNR of the system is increased. A 12- bit A/D converter is used to improve the image quality. The output rate of the imaging system designed with integrated chip can reach to 1.3 frames per second through bi-channel. For its good performance  low power consumption and small volume  the driving system can be applied to aeronautics and astronautics field. With a further improvement  a maximum data output rate of 2.7 frames per second can be reached through all the eight channels of the two CCDs. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Driving and image enhancement for CCD sensing image system (EI CONFERENCE) 会议论文  OAI收割
2010 3rd IEEE International Conference on Computer Science and Information Technology, ICCSIT 2010, July 9, 2010 - July 11, 2010, Chengdu, China
Zhang M.; Ren J.
收藏  |  浏览/下载:36/0  |  提交时间:2013/03/25
The paper designs a driving circuit of high sensitive  wide dynamic for CCD sensing imaging system which adopts a Dalsa-made high resolution full-frame 33-mega pixels area CCD FTF5066M. Field Programmable Gate Array (FPGA) is used as the main device to accomplish the timing design of the circuits and power driver control of the sensor. By using the Correlated Double Sampling (CDS) technique  the video noise is reduced and the SNR of the system is increased. The output rate of the imaging system designed with integrated chip can reach to 1.3 frames per second through bi-channel output. We use the histogram specification to adjust the brightness of the captured image. And then use the median filtering to suppress the noise. The traditional gray mean gradient (GMG) and the objective evaluation method based on Human Visual System (HVS) used to verify the effect of image enhancement. 2010 IEEE.  
Angular rate of test table based on high-speed non-contact measurement (EI CONFERENCE) 会议论文  OAI收割
9th International Conference on Electronic Measurement and Instruments, ICEMI 2009, August 16, 2009 - August 19, 2009, Beijing, China
作者:  
Yang L.;  Zhao Y.;  Zhao Y.;  Zhao Y.;  Yang L.
收藏  |  浏览/下载:147/0  |  提交时间:2013/03/25
This article will introduces a high-speed non-contact method that can measures the angular rate of a test table though an objective perspective. This method adopts a collimator tube that can be measured as a target fixed to the test table  and the target corresponds to the angular position of the test table. In the process of the table rotating  the camera will to keep track of the objective at a high speed. Due to the high sampling frequency of the high-speed camera  instantaneous angular rate of test table can be measured. With pixel subdivision technology  its measuring accuracy can be up to 0.02 pixels. We use this methods measured a low-speed test table's angular rate and analyzed the data. The error analysis shows when the rate of the test table is 0.20/s  the accuracy of the method can achieve 0.0220%. 2009 IEEE.