IPGAN: Identity-Preservation Generative Adversarial Network for unsupervised photo-to-caricature translation
期刊论文
OAI收割
KNOWLEDGE-BASED SYSTEMS, 2022, 卷号: 241, 页码: 11
作者:
Yan, Lan
;
Zheng, Wenbo
;
Gou, Chao
;
Wang, Fei-Yue
  |  
收藏
  |  
浏览/下载:34/0
  |  
提交时间:2022/06/10
Photo-to-caricature translation
Generative adversarial networks
Image-to-image translation
Style transfer
Image warping
Image style disentangling for instance-level facial attribute transfer
期刊论文
OAI收割
COMPUTER VISION AND IMAGE UNDERSTANDING, 2021, 卷号: 207, 页码: 10
作者:
Guo, Xuyang
;
Kan, Meina
;
He, Zhenliang
;
Song, Xingguang
;
Shan, Shiguang
  |  
收藏
  |  
浏览/下载:64/0
  |  
提交时间:2021/12/01
Instance-level facial attribute transfer
Image to image translation
Generative adversarial network
Weakly supervised style learning
Multi-Domain Image-to-Image Translation via a Unified Circular Framework
期刊论文
OAI收割
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2021, 卷号: 30, 页码: 670-684
作者:
Wang, Yuxi
;
Zhang, Zhaoxiang
;
Hao, Wangli
;
Song, Chunfeng
  |  
收藏
  |  
浏览/下载:43/0
  |  
提交时间:2021/03/02
Task analysis
Semantics
Visualization
Generative adversarial networks
Generators
Feature extraction
Meteorology
Image-to-image transfer
multiple domain pairs
sharing knowledge module
GANs
Adaptively-Weighted Blind Image Restoration Algorithm Based on Energy Constraint
期刊论文
OAI收割
Guangxue Xuebao/Acta Optica Sinica, 2018, 卷号: 38, 期号: 2
作者:
Su, Chang
;
Fu, Tianjiao
;
Zhang, Xingxiang
;
Ren, Jianyue
;
Jin, Longxu
  |  
收藏
  |  
浏览/下载:18/0
  |  
提交时间:2019/09/17
Image reconstruction
Adaptive optics
Image enhancement
Image processing
Image resolution
Image texture
Optical data processing
Optical transfer function
Remote sensing
Restoration
Signal to noise ratio
Transfer functions
Space camera dynamic image quality measurement and evaluation (EI CONFERENCE)
会议论文
OAI收割
3rd International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2011, January 6, 2011 - January 7, 2011, Shanghai, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2013/03/25
By using analysis of the infinity image of the space camera
we intend to obtain the curve of the dynamic modulation transfer function. We extract the pixel gray values at the image edge which distribute as a knife-edge function
and make differential calculation and Fourier transformation of it
and then we can obtain the dynamic MTF curve of the optical system. The value of the curve at the Nyquist frequency is the most important parameter that reflects the image quality. We add push-scanning imaging and environmental effects to the static MTF of space camera and compare the MTF value with the dynamic MTF at Nyquist frequency. The comparison result can help us verify the accuracy of the calculating results and the feasibility of our method. (2011) Trans Tech Publications.
Design of reimaging F/1.0 long-wavelength infrared optical system (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2013/03/25
A reimaging F/1.0 long-wavelength infrared optical system is proposed. The design has a flexible opto-mechanical layout. The design process is as follows. Firstly
the catadioptric reimaging system consists of two reflecting mirrors and a relay lenses. Two reflecting mirrors make up of the first imaging system and are therefore free of chromatic aberrations
while low dispersion lenses were used in the reimaging system
so the optical system do not need achromatic design for a high image quality. Then
to correct high-order aberrations resulting from large relative aperture
more parameters need to be used with aspheric or diffractive surfaces due to modern optic technology development. Here
aspheric is selected for easily manufacture. Finally
the design is completed with the help of ZEMAX software. The effective focal length of the objective is 120mm and the field of view (FOV) is 4. The simulated final design shows adequate image quality and the modulation transfer function (MTF) is close to diffraction limit. The effect of the surrounding environmental temperature is analyzed using the concept of thermal defocusing
and the thermal compensation is discussed. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Space optical remote sensor of the CAE thermal control index calculation method (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Advanced Design and Manufacturing Engineering, ADME 2011, September 16, 2011 - September 18, 2011, Guangzhou, China
作者:
Li L.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
The thermal control indicators CAE methods of Space optical remote sensor are analyzed in the presented work. We sat up a thermal optical analysis model for space optical remote sensor. By assuming fully covered by in-orbit temperature load
and using the finite element method for thermal deformation analysis
we obtained the optical remote sensor surface deformation and displacement under various thermal loading. Using ZERNIKE polynomial
wave was fitted to obtain ZERNIKE polynomial coefficients which were incorporated into the optical system design. Using CODE V optical calculation software
heat-ray machines under elastic deformation of the system point spread function
transfer function (MTF)
wave front differential (WFE) etc. were calculated. Image quality changes of remote sensors are discussed in variety assumed cases such as temperature loads of quality change. By repeated iteration
critical value of temperature fields meeting the design requirements are obtained for the optical system. Optical indicators were converged to the temperature field indicator
then reasonable indicators of thermal control for remote sensors were obtained. For the thermal control design
this method provided a reliable basis for design. (2011) Trans Tech Publications
Switzerland.
The application of diagnostic equipment in the Tokamak fusion reaction (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Optical Instruments and Technology: Optical Systems and Modern Optoelectronic Instruments, November 6, 2011 - November 9, 2011, Beijing, China
Zhang B.-S.
;
Chang J.
;
Gong X.-Z.
;
Gan J.-F.
;
Feng S.-L.
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2013/03/25
This paper introduces the infrared optical system in the Tokamak fusion reaction device. In this optical system
3.the relay group lenses. This paper describes the decrease of the modulation transfer function (MTF) when the temperature changes and how to compensate the decrease of the MTF in order to maintain the image quality in a high level. As a result
the traditional optical structure can't meet the requirements
2.the Cassegrain system
the image quality of this optical system can reach the requirements when the temperature changes. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
because the length of the infrared optical system in the Tokamak is very long. The design of optical system in the detection facility includes three parts:1.the combination of the concave aspheric mirror and flat mirror
Imaging control of airborne area CCD mapping camera (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Mechatronic Science, Electric Engineering and Computer, MEC 2011, August 19, 2011 - August 22, 2011, Jilin, China
作者:
Chen X.
;
Chen X.
;
Chen X.
收藏
  |  
浏览/下载:18/0
  |  
提交时间:2013/03/25
Digital mapping camera is an important tool for modern airborne photogrammetry. Monochromic area CCD which is full frame transfer is selected as image sensor in this paper. Electronic shutter is utilized to eliminate the opening delay of mechanical shutter which will affect the precision of exterior orientation elements acquisition. The equation for calculation displacement of principal point is proposed for TDI forward image motion compensation to compensate principal point shift. Imaging pose control system is designed in order to meet the need for airborne stereo mapping. 2011 IEEE.
The research of the accurate measure of static transfer function for the TDI CCD camera (EI CONFERENCE)
会议论文
OAI收割
3rd International Photonics and OptoElectronics Meetings, POEM 2010, November 2, 2010 - November 5, 2010, Wuhan, China
Guo-Ning L.
;
Long-Xu J.
;
Jian-Yue R.
;
Wen-Hua W.
;
Shuang-Li H.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
In the test course of static transfer function of TDI CCD camera
because of the influence that gets environmental and artificial etc. factor
the value of static transfer function measured at any time is between unceasing fluctuation
so
make accuracy reduce. To solve this problem
a kind of accurate measurement technique of static transfer function is put forward. First
before carrying out the measure of static quiet of transfer function
the best test point of transfer function of the TDI CCD camera must be determined
it is parallel to guarantee the rectangle target surface of parallel optical pipe and camera focal plane maintenance parallel
and again guarantee target strip in rectangle target and TDI CCD in camera focal plane maintenance vertical. TDI CCD catches rectangle target image
per 1000 lines of target mark image as a measures sample of static transfer function
exclude because of atmosphere tremble twisted
vague rectangle target mark image
retain 500 distinct and steady target mark image as measure sample set. Then
calculate the static transfer function of each measure sample respectively
take the average of all static quiet transfer function in measure sample set as the static transfer function of camera. Finally
the measure of the static transfer function for TDI CCD camera makes error analysis. Experimental results indicate that the value of the static transfer function of TDI CCD camera measured with this kind of method is 0.2923
with before measurement technique comparison
the value of static transfer function has raised 0.02
makes the accuracy of the measure of static transfer function have gotten raising.