南疆三地州贫困人口的精准识别及影响机制 学位论文  OAI收割
新疆乌鲁木齐: 中国科学院大学, 2017
作者:  
呼梦霞
  |  收藏  |  浏览/下载:41/0  |  提交时间:2018/12/28
开放数据计量研究综述:计算网络用户行为和科学社群影响力的Altmetrics计量 期刊论文  OAI收割
现代图书情报技术, 2013, 卷号: 234, 期号: 6, 页码: 1-8
作者:  
顾立平
收藏  |  浏览/下载:118/0  |  提交时间:2013/08/05
Inspection focus technology of space tridimensional mapping camera based on astigmatic method (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optoelectronic Materials and Devices for Detector, Imager, Display, and Energy Conversion Technology, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Wang Z.;  Wang Z.;  Zhang L.;  Zhang L.
收藏  |  浏览/下载:25/0  |  提交时间:2013/03/25
The CCD plane of the space tridimensional mapping camera will be deviated from the focal plane(including the CCD plane deviated due to camera focal length changed)  under the condition of space environment and vibration  impact when satellite is launching  image resolution ratio will be descended because defocusing. For tridimensional mapping camera  principal point position and focal length variation of the camera affect positioning accuracy of ground target  conventional solution is under the condition of vacuum and focusing range  calibrate the position of CCD plane with code of photoelectric encoder  when the camera defocusing in orbit  the magnitude and direction of defocusing amount are obtained by photoelectric encoder  then the focusing mechanism driven by step motor to compensate defocusing amount of the CCD plane. For tridimensional mapping camera  under the condition of space environment and vibration  impact when satellite is launching  if the camera focal length changes  above focusing method has been meaningless. Thus  the measuring and focusing method was put forward based on astigmation  a quadrant detector was adopted to measure the astigmation caused by the deviation of the CCD plane  refer to calibrated relation between the CCD plane poison and the asrigmation  the deviation vector of the CCD plane can be obtained. This method includes all factors caused deviation of the CCD plane  experimental results show that the focusing resolution of mapping camera focusing mechanism based on astigmatic method can reach 0.25 m. 2010 Copyright SPIE - The International Society for Optical Engineering.  
In situ long trace profiler for measurement of Wolter type-I mirror (EI CONFERENCE) 会议论文  OAI收割
Advances in Metrology for X-Ray and EUV Optics III, August 1, 2010 - August 2, 2010, San Diego, CA, United states
作者:  
Chen B.;  Chen B.
收藏  |  浏览/下载:27/0  |  提交时间:2013/03/25
The surface profile of Wolter type-I mirror has a great impact on the performance of Solar X-ray Telescope. According to the existing fabrication instrument and experimental conditions in our lab  an in situ Long Trace Profiler is developed and set up on the fabrication instrument in order to measure the surface profile of Wolter mirror in real time during fabrication process. Its working mechanism  structural parameters and data processing algorithm are investigated. The prototype calibrated by a standard plane mirror is used to measure a sample of Wolter type-I mirror. The results show that our prototype can achieve an accuracy of 2.6rad rms for slope error with a stability of 1.33rad during the whole measurement period. This can meet further fabrication requirements. 2010 Copyright SPIE - The International Society for Optical Engineering.