中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共6条,第1-6条 帮助

条数/页: 排序方式:
Mining-induced ground deformation in tectonic stress metal mines: A case study 期刊论文  OAI收割
ENGINEERING GEOLOGY, 2016, 卷号: 210, 页码: 212-230
作者:  
Xia, Kaizong;  Chen, Congxin;  Fu, Hua;  Pan, Yucong;  Deng, Yangyang
  |  收藏  |  浏览/下载:18/0  |  提交时间:2018/06/05
A developed full-field fem analysis combined with ESPI for the investigation of defect evolution in polymer films 期刊论文  OAI收割
CHINESE JOURNAL OF POLYMER SCIENCE, 2013, 卷号: 31, 期号: 7, 页码: 1022-1028
作者:  
Liu, Xiao-fang;  Tan, Shuai-xia;  Zhang, Xiao-li;  Zhao, Ning;  Xu, Jian
  |  收藏  |  浏览/下载:24/0  |  提交时间:2019/04/09
Research on the the device of non-angular vibration for opto-electronic platform (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Smart Structures and Materials in Manufacturing and Testing, April 26, 2010 - April 29, 2010, Dalian, China
An Y.; Song C.-P.; Kuang R.-J.; Jin G.
收藏  |  浏览/下载:31/0  |  提交时间:2013/03/25
The opto-electronic platform is the main equipment for aviation reconnaissance. It is a surveillance system with the function of search  recognition orientation and tracking by opto- electronic instruments. It is made up of opto-electronic instruments which are used to get high quality image  and stabilization tracking system to control stabilization and gesture of platform for exact tracking. The opto-electronic platform purpose is to achieve high quality image. Besides the impact of optic system  the image quality of the system is influenced greatly in the vibration environment. The research worked by Zhao peng which demonstrated the affection caused by angular vibration was worse than which caused by line vibration  and what was multiplied direct ratio with plane altitude. So it is necessary to design a new device which could be used widely and has good angular vibration isolation effect. According to the theory of parallelogram  the non-angular vibration device had been designed with spatial links  and the theory of non-angular vibration was analyzed. The three-dimensional model was set with UG  the analysis was done by ADAMS/vibration software. The acceleration and displacement response of the device in each direction was calculated by inspiriting it with sine wave of the acceleration in three directions  and the stiffness and damp were studied. All the work prove the design principle of the device is reasonable  and the device is adopted to keep the platform motion moving horizontally  at the meantime the device is good at isolating vibration in all directions. 2010 SPIE.  
Method of improving the accuracy of image motion measurement for panoramic aerial cameras (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optoelectronic Materials and Devices for Detector, Imager, Display, and Energy Conversion Technology, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Jia P.
收藏  |  浏览/下载:25/0  |  提交时间:2013/03/25
To improve the accuracy of image motion measurement for panoramic aerial cameras  the paper proposed a method of real-time image motion measurement based on 2D spatial correlation. An auxiliary area CCD is positioned paralleled to the main linear TDI CCD in the focal plane of the camera. For every frame of the image sequence taken by the auxiliary CCD  a prediction on the displacement of the current image in the flight direction is made based on the forward image motion velocity. The current and the reference images are combined together for 2D-correlation  which products an image motion vector. By decomposing the vector  both the forward and pendulum-swing image motions can be determined. The demanding computational requirements for the real-time 2D-correlation are covered by a joint transform optical correlator. Simulation test results show that the accuracy is improved and the measurement error is within 0.2 pixels for input images with SNR=1 dB. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Application of precision harmonic gear drive in focusing mechanism of space camera (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Smart Structures and Materials in Manufacturing and Testing, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:26/0  |  提交时间:2013/03/25
A kind of precision harmonic gear drive in the focusing mechanism of space camera is studied  which adopt external meshing complex wave transmission mode. Wave generator is combined with an elliptic cam and a flexible bearing around it. Flexspline is a structure of single wave with the same teeth. The output shaft is supported by a single cross-roller bearing. Ball screws connected the output shaft translate the rotational motion to the linear motion  and drive the focusing mirror repeated moving along the linear guide. The output rigid wheel is connected with absolute encoder to detect displacement of focusing movement. It has the characteristics of big transmission ratio  high precision  compact structure  high efficiency and smooth running etc. According to the practical application of this harmonic gear drive in the space camera  the location relationship between the displacement of focusing structure and the focal plane movement is derived  and the system error is analyzed  its accuracy is tested with the open-loop control method. Experimental results show that transmission ratio of the instrument is 1:70  repeated positional accuracy is 2m  which meet the requirements for use. 2010 SPIE.  
Study of high precision non-contact measurement based on CCD (EI CONFERENCE) 会议论文  OAI收割
4th International Conference on Information Technology and Applications, ICITA 2007, January 15, 2007 - January 18, 2007, Harbin, China
Lin L.; Yun F.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
In this paper a method that measures relatively positionrelationshipquickly and accurately between two vehicles both on a horizontal plane is introduced. When the linear CCD camera placed on the end of manipulator scans two point targets located on the other vehicle  by virtue of the spatial intersection principle and trigonometry theorem  the relative position relationship between the loading vehicles and launching ones can be gotten(i.e. the spatial coordinate parameters of x  y  z and the angle displacement ). At the same time the paper establishes that the measurement error of length is less than 1mm  by analysis of thee rror analysis and the simulation of computer. The angle displacement is less than 3  which satisfies the technical requests. So the vehicle orientation and loading missiles can be both done at the shortest time. It meets the demand of centralization between the measurement and execution. Forboth automatic transshipment and spatial position relationship measurement  the study is valuable. And the manipulator is measure device as well as executive one so that residual inherent error decreases according to identical reference principle. Therefore the measure precision can be improved greatly.