中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
西安光学精密机械研究... [3]
自动化研究所 [2]
长春光学精密机械与物... [1]
采集方式
OAI收割 [6]
内容类型
会议论文 [4]
期刊论文 [2]
发表日期
2023 [1]
2020 [1]
2019 [1]
2017 [2]
2010 [1]
学科主题
筛选
浏览/检索结果:
共6条,第1-6条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
A high-performance visible framing ICCD camera base on the image intensifier
会议论文
OAI收割
Shihezi City, China, 2023-08-08
作者:
Zheng, Jinkun
;
Chen, Zhen
;
Qin, Wenqiang
;
Qin, Junjun
;
Bai, Yonglin
  |  
收藏
  |  
浏览/下载:11/0
  |  
提交时间:2024/08/16
framing ICCD camera
low light level
image intensifier
coupled lens
high-voltage gate module. formatting
The analysis of electron scattering among multiplying layer in EBAPS using optimized Monte Carlo method
期刊论文
OAI收割
MODERN PHYSICS LETTERS B, 2020, 卷号: 34, 期号: 34
作者:
Bai, Jinzhou
;
Bai, Yonglin
;
Hou, Xun
;
Cao, Weiwei
;
Yang, Yang
  |  
收藏
  |  
浏览/下载:53/0
  |  
提交时间:2021/01/07
EBAPS
image sensor
low light level
single photon
Study on the technology of high-dynamic-range low-light-level remote-sensing camera
会议论文
OAI收割
Xiamen, China, 2019-10-18
作者:
Bai, Zhe
;
Ma, Yilong
;
Huang, Chao
;
Fan, Xuewu
  |  
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2020/06/18
low light level
remote sensing camera
ICCD
dynamic range
image intensifier
Practical Method of Low-Light-Level Binocular Ranging Based on Triangulation and Error Correction
会议论文
OAI收割
Kalbis Institute, Jakarta, Indonesia, December 5-7, 2017
作者:
Qi Shi
;
Lei Ma
;
Yiping Yang
  |  
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2018/01/29
Low-light-level Image
Binocular Stereo Vision
Triangulation
Trilateration
Error Correction
Enhancement of LLLIs with improved BCP and matrix completion
期刊论文
OAI收割
ELECTRONICS LETTERS, 2017, 卷号: 53, 期号: 9, 页码: 586-587
作者:
Yang, Jie
  |  
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2017/06/06
Low Light Level Image Enhancement
Matrix Completion
Bright Channel Prior
Coarse-to-fine Framework
Development and radiance calibration of three-waveband camera (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photonics and Optoelectronics, SOPO 2010, June 19, 2010 - June 21, 2010, Chengdu, China
作者:
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
An imaging system with three-waveband sharing one lens and an area CCD was developed. By rotating different filters into the beam path
the required waveband was selected. The optical system which can image in ultraviolet
visible and near infrared region was designed and the signal collecting system was integrated. The optical design and system integration have some advantages such as low cost
small size and light in weight. To obtain a high imaging quality
the radiation calibration is carried out in order to establish the relation between the average grey level of output image and the input radiance from the integrating sphere. According to the calibration data in experiments
the radiation dynamic range and the best working point of the system are determined. The experiment result shows that the dynamic range of the image system is maximal when the exposure time is 8ms in ultraviolet
0.5ms in visible and 0.125ms in near infrared region. 2010 IEEE.