中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [3]
数学与系统科学研究院 [1]
采集方式
OAI收割 [4]
内容类型
会议论文 [3]
期刊论文 [1]
发表日期
2016 [1]
2013 [1]
2009 [1]
2008 [1]
学科主题
筛选
浏览/检索结果:
共4条,第1-4条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Variable selection for frailty transformation models with application to diabetic complications
期刊论文
OAI收割
CANADIAN JOURNAL OF STATISTICS-REVUE CANADIENNE DE STATISTIQUE, 2016, 卷号: 44, 期号: 3, 页码: 375-394
作者:
Liu, Xu
;
Song, Xinyuan
;
Xie, Shangyu
;
Zhou, Yong
  |  
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2018/07/30
Diabetic complications
Gamma frailty
MM algorithm
SCAD
transformation models
variable selection
MSC 2010: Primary 62G08
secondary 62N01
Weighted data fusion algorithm in the application of visual measurement network system (EI CONFERENCE)
会议论文
OAI收割
2012 International Conference on Mechatronics and Control Engineering, ICMCE 2012, November 29, 2012 - November 30, 2012, Guangzhou, China
作者:
Zhang Y.-c.
;
Zhou J.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
For the problem on the deviation of actual measurement values between different network positions of visual measurement network system
so present the weighted data fusion algorithm. To distribute the weight coefficients according to the stability of eigenvector and fuse the coordinates
finally get the ultimate expression of fusion estimate. The experiment results present the maximum absolute tolerance of the fusion results is 0.039mm via the weighted data fusion algorithm
the maximum one via traditional data fusion algorithm of the center of point set is 0.056mm
Repeatedly measure 50 times
compared with the traditional algorithm
proposed weighted data fusion algorithm has much better precision and better stability. (2013) Trans Tech Publications
Switzerland.
Test of an off-axis asphere by subaperture stitching interferometry (EI CONFERENCE)
会议论文
OAI收割
4th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, November 19, 2008 - November 21, 2008, Chengdu, China
作者:
Zheng L.-G.
;
Zhang X.-J.
;
Zhang Z.-Y.
;
Zhang Z.-Y.
;
Deng W.-J.
收藏
  |  
浏览/下载:54/0
  |  
提交时间:2013/03/25
A new method combined subaperture stitching with interferometry(SSI) is introduced. It can test large and off-axis aspheric surfaces without the aid of other null optics. In this paper the basic principle and theory of the technique are analyzed. The synthetical optimization stitching model and effective stitching algorithm are established based on homogeneous coordinates transformation and simultaneous least-squares method. The software of SSI is devised and the prototype for testing of large aspheres by SSI is designed and developed. An off-axis asphere with the aperture of 376mm188mm is tested by this method. For comparison and validation
and the difference of PV and RMS error between them is 0.047 e and 0.006 e
the asphere is also tested by null compensation.The synthesized surface profile is consistent to that ofthe entire surface from null test
respectively. So it provides another quantitative measurement for testing large aspheric surfaces and off-axis aspheres besides null-compensation. 2009 SPIE.
Novel algorithm for computer-aided alignment of wide field of view complex optical system (EI CONFERENCE)
会议论文
OAI收割
Yang X.
;
Han C.
收藏
  |  
浏览/下载:32/0
  |  
提交时间:2013/03/25
With the advent of the new complex optical system
alignment technology is necessary. In this paper
is presented an alignment algorithm whose main idea is composed of damped least square method and singular value decomposition method. In addition
the how and why to enter the damped factor into algorithm is explained. According to this algorithm
an alignment software package was compiled and compared self-compiled software with alignment package of CODE V. Results show that
this self-compiled software is much more valid than alignment package of CODE V. For a field of view of 2 R-C system
average MTF over the field of view was greater than 0.3 at 50 line pairs /mm.