中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
武汉岩土力学研究所 [3]
成都山地灾害与环境研... [2]
金属研究所 [1]
长春光学精密机械与物... [1]
采集方式
OAI收割 [7]
内容类型
期刊论文 [6]
会议论文 [1]
发表日期
2024 [2]
2022 [1]
2014 [1]
2011 [1]
2007 [1]
2005 [1]
更多
学科主题
Engineerin... [1]
Geology [1]
筛选
浏览/检索结果:
共7条,第1-7条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
作者升序
作者降序
Impact dynamics of granular flow on rigid barriers: insights from numerical investigation using material point method
期刊论文
OAI收割
JOURNAL OF MOUNTAIN SCIENCE, 2024, 卷号: 21, 期号: 12, 页码: 4083-4111
作者:
Yu, Fangwei
;
Su, Lijun
;
Li, Xinpo
;
Zhao, Yu
|
收藏
|
浏览/下载:7/0
|
提交时间:2025/01/24
Column collapse
Granular flow
Impact force
Material point method
Numerical tests
Rigid barrier
Mobility and dynamic erosion process of granular flow: insights from numerical investigation using material point method
期刊论文
OAI收割
JOURNAL OF MOUNTAIN SCIENCE, 2024, 卷号: 21, 期号: 8, 页码: 2713-2738
作者:
Yu, Fangwei
;
Su, Lijun
;
Li, Xinpo
;
Zhao, Yu
|
收藏
|
浏览/下载:16/0
|
提交时间:2024/09/24
Column collapse
Granular flow
Granular soil
Material point method
Mobility
Numerical tests
Evolution of the anti-weathering characteristics of clay at earthen sites treated with K2SiO3 solutions: Micromechanism analysis based on SEM tests
期刊论文
OAI收割
BULLETIN OF ENGINEERING GEOLOGY AND THE ENVIRONMENT, 2022, 卷号: 81, 期号: 10, 页码: -
作者:
Zhang, Yao
;
Guo, Shaoqiang
;
Yin, Xiaotao
;
Han, ShunLi
;
Shao, Shuai
|
收藏
|
浏览/下载:16/0
|
提交时间:2023/08/02
Inorganic chemical material
Wind erosion tests
Structure
SEM tests
Physical Simulation on Failure around a Circular Cavern in Hard and Brittle Rock under High and Increasing Natural Stress Conditions
期刊论文
OAI收割
JOURNAL OF ENGINEERING MECHANICS, 2014, 卷号: 140, 期号: 2, 页码: 332-344
作者:
Bai, Shiwei
;
Chen, Luwang
;
Yin, Xiaoxi
|
收藏
|
浏览/下载:29/0
|
提交时间:2018/06/05
Rock mechanic
Model tests
Experimentation
Material failures
Parameters
Simulation
Rock mechanic
Model test
Physical model material
Numerical experiment
Failure
Yielding parameters
Evaluation of mechanical properties of structural materials by a spherical indentation based on the representative strain-an improved algorithm at great depth ratio
期刊论文
OAI收割
Acta Metallurgica Sinica-English Letters, 2011, 卷号: 24, 期号: 5, 页码: 405-414
J. Chen
;
H. N. Chen
收藏
|
浏览/下载:108/0
|
提交时间:2012/04/13
Spherical indentation
Representative strain
Metallic engineering
structural material
Mechanical property
Great depth ratio
measuring elastoplastic properties
energy-based method
plastic
properties
conical indentation
metal materials
hardness definitions
bulk materials
extract
tests
Study on elastic modulus and recovery coefficient of cushioning materials in pile driving
期刊论文
OAI收割
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2007, 卷号: 19, 期号: 4, 页码: 313-320
作者:
Zhou, Liyun
;
Lao, Weikang
;
Chen, Jianbin
|
收藏
|
浏览/下载:13/0
|
提交时间:2018/06/05
Pile Driving
Geotechnical Engineering
Mechanical Properties
Material Tests
Elasticity
The replacement of dry heat in generic reliability assurance requirements for passive optical components (EI CONFERENCE)
会议论文
OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
作者:
Zhang G.
;
Zhang G.
;
Zhang G.
收藏
|
浏览/下载:24/0
|
提交时间:2013/03/25
According to Generic Reliability Assurance Requirements for Passive Optical Components GR-1221-CORE (Issue 2
January 1999)
reliability determination test of different kinds of passive optical components which using in uncontrolled environments is taken. The test condition of High Temperature Storage Test (Dry Test) and Damp Test is in below sheet. Except for humidity condition
all is same. In order to save test time and cost
after a sires of contrast tests
the replacement of Dry Heat is discussed. Controlling the Failure mechanism of dry heat and damp heat of passive optical components
the contrast test of dry heat and damp heat for passive optical components (include DWDM
CWDM
Coupler
Isolator
mini Isolator) is taken. The test result of isolator is listed. Telcordia test not only test the reliability of the passive optical components
but also test the patience of the experimenter. The cost of Telcordia test in money
manpower and material resources
especially in time is heavy burden for the company. After a series of tests
we can find that Damp heat could factually test the reliability of passive optical components
and equipment manufacturer in accord with component manufacture could omit the dry heat test if damp heat test is taken first and passed.
首页
上一页
1
下一页
末页