中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共7条,第1-7条 帮助

条数/页: 排序方式:
Impact dynamics of granular flow on rigid barriers: insights from numerical investigation using material point method 期刊论文  OAI收割
JOURNAL OF MOUNTAIN SCIENCE, 2024, 卷号: 21, 期号: 12, 页码: 4083-4111
作者:  
Yu, Fangwei;  Su, Lijun;  Li, Xinpo;  Zhao, Yu
  |  收藏  |  浏览/下载:7/0  |  提交时间:2025/01/24
Mobility and dynamic erosion process of granular flow: insights from numerical investigation using material point method 期刊论文  OAI收割
JOURNAL OF MOUNTAIN SCIENCE, 2024, 卷号: 21, 期号: 8, 页码: 2713-2738
作者:  
Yu, Fangwei;  Su, Lijun;  Li, Xinpo;  Zhao, Yu
  |  收藏  |  浏览/下载:16/0  |  提交时间:2024/09/24
Evolution of the anti-weathering characteristics of clay at earthen sites treated with K2SiO3 solutions: Micromechanism analysis based on SEM tests 期刊论文  OAI收割
BULLETIN OF ENGINEERING GEOLOGY AND THE ENVIRONMENT, 2022, 卷号: 81, 期号: 10, 页码: -
作者:  
Zhang, Yao;  Guo, Shaoqiang;  Yin, Xiaotao;  Han, ShunLi;  Shao, Shuai
  |  收藏  |  浏览/下载:16/0  |  提交时间:2023/08/02
Physical Simulation on Failure around a Circular Cavern in Hard and Brittle Rock under High and Increasing Natural Stress Conditions 期刊论文  OAI收割
JOURNAL OF ENGINEERING MECHANICS, 2014, 卷号: 140, 期号: 2, 页码: 332-344
作者:  
Bai, Shiwei;  Chen, Luwang;  Yin, Xiaoxi
  |  收藏  |  浏览/下载:29/0  |  提交时间:2018/06/05
Evaluation of mechanical properties of structural materials by a spherical indentation based on the representative strain-an improved algorithm at great depth ratio 期刊论文  OAI收割
Acta Metallurgica Sinica-English Letters, 2011, 卷号: 24, 期号: 5, 页码: 405-414
J. Chen; H. N. Chen
收藏  |  浏览/下载:108/0  |  提交时间:2012/04/13
Study on elastic modulus and recovery coefficient of cushioning materials in pile driving 期刊论文  OAI收割
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2007, 卷号: 19, 期号: 4, 页码: 313-320
作者:  
Zhou, Liyun;  Lao, Weikang;  Chen, Jianbin
  |  收藏  |  浏览/下载:13/0  |  提交时间:2018/06/05
The replacement of dry heat in generic reliability assurance requirements for passive optical components (EI CONFERENCE) 会议论文  OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
作者:  
Zhang G.;  Zhang G.;  Zhang G.
收藏  |  浏览/下载:24/0  |  提交时间:2013/03/25
According to Generic Reliability Assurance Requirements for Passive Optical Components GR-1221-CORE (Issue 2  January 1999)  reliability determination test of different kinds of passive optical components which using in uncontrolled environments is taken. The test condition of High Temperature Storage Test (Dry Test) and Damp Test is in below sheet. Except for humidity condition  all is same. In order to save test time and cost  after a sires of contrast tests  the replacement of Dry Heat is discussed. Controlling the Failure mechanism of dry heat and damp heat of passive optical components  the contrast test of dry heat and damp heat for passive optical components (include DWDM  CWDM  Coupler  Isolator  mini Isolator) is taken. The test result of isolator is listed. Telcordia test not only test the reliability of the passive optical components  but also test the patience of the experimenter. The cost of Telcordia test in money  manpower and material resources  especially in time is heavy burden for the company. After a series of tests  we can find that Damp heat could factually test the reliability of passive optical components  and equipment manufacturer in accord with component manufacture could omit the dry heat test if damp heat test is taken first and passed.  
  • 首页
  • 上一页
  • 1
  • 下一页
  • 末页