中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
地球环境研究所 [1]
采集方式
OAI收割 [3]
_filter
_filter
_filter
筛选
浏览/检索结果:
共3条,第1-3条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
作者升序
作者降序
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
Research of ballistic missile early warning system (EI CONFERENCE)
会议论文
OAI收割
2nd International Conference on Advanced Engineering Materials and Technology, AEMT 2012, July 6, 2012 - July 8, 2012, Zhuhai, China
Zhang M.-H.
;
Zhang Y.-Y.
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2013/03/25
To develop a lift early warning infrared device
as a part of land or boat (ship) early warning system
the system has the ability to target pre-discovery and instructions invasion. Methods: In support of distant air situation
alerts the enemy aircraft
missiles and other long-range goals
obtain the target type and preliminary judgment of grade
deliver the alarm information to the command system. The infrared alarm device detects the target's own infrared radiation passively
alarms the incoming targets at low altitude and low altitude remote
when radar and other equipment is out of work. Results: The accuracy of entire system reached 20 according the analysis. Conclusions: The device has a full range of complex background
with high sensitivity
high resolution
anti-jamming
fast response time and other characteristics. (2012) Trans Tech Publications
Switzerland.
Effect of preservation on the δ13C value of dissolved inorganic carbon in different types of water samples
期刊论文
OAI收割
Isotopes in Environmental and Health Studies, 2011, 卷号: 47, 期号: 3, 页码: 379-389
作者:
Li,XZ(Li,Xiangzhong)[1]
;
Liu,WG(Liu,Weiguo)[1,2]
  |  
收藏
  |  
浏览/下载:15/0
  |  
提交时间:2018/12/19
Carbon-13
Dissolved Inorganic Carbon
Isotope Measurements
Methods And Equipment
Preservation Method
Storage Time
Study on medical X-ray coherent scatter imaging and processing based digital flat detector (EI CONFERENCE)
会议论文
OAI收割
3rd International Conference on BioMedical Engineering and Informatics, BMEI 2010, October 16, 2010 - October 18, 2010, Yantai, China
作者:
Li B.
;
Zhao J.
;
Li B.
;
Li B.
;
Liu J.
收藏
  |  
浏览/下载:32/0
  |  
提交时间:2013/03/25
It is introduced a novel imaging technique for medical diagnostic X-ray coherent scatter in this paper. A set of experimental equipment for X-ray coherent scatter imaging was set up with X-ray digital flat detector and medical diagnostic X-ray source. According to this equipment
the scatter images obtained are made of some circles with the same center. It is vital to calculate the energy template to classify the different samples. It is difficult to separate them using the traditional threshold method due to noise and overlapped shadow. In this paper
the image was transformed a binary image by using K-Means algorithm and Mathematical Morphology Methods. The effective region was extracted from the binary image inside the orthogonal energy projection space
then to calculate the centroid of rings. Consequently the curve of the energy distribution was built. The experiment results show that our method is reasonable and feasible. The technique will have wide foreground of application .Besides the imaging of human bone content
it can be used for various imaging of tissue and organs in biology. 2010 IEEE.