中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
成都生物研究所 [1]
采集方式
OAI收割 [3]
内容类型
会议论文 [2]
期刊论文 [1]
发表日期
2018 [1]
2011 [1]
2010 [1]
学科主题
筛选
浏览/检索结果:
共3条,第1-3条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
作者升序
作者降序
DETERMINATION AND ANALYSIS OF KINETIC PARAMETERS OF HETEROTROPHIC BACTERIA IN MATHEMATICAL SIMULATION
期刊论文
OAI收割
APPLIED ECOLOGY AND ENVIRONMENTAL RESEARCH, 2018, 卷号: 16, 期号: 2, 页码: 1507-1518
作者:
Lv, W. L.
;
Gou, S. Z.
;
Chen, Y. W.
;
Sun, Y. F.
;
Gao, X. D.
  |  
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2020/12/24
anaerobic-anoxic-oxic
kinetic parameters (YH, uH, bH)
mathematical simulation
OUR curve
Space camera dynamic image quality measurement and evaluation (EI CONFERENCE)
会议论文
OAI收割
3rd International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2011, January 6, 2011 - January 7, 2011, Shanghai, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
By using analysis of the infinity image of the space camera
we intend to obtain the curve of the dynamic modulation transfer function. We extract the pixel gray values at the image edge which distribute as a knife-edge function
and make differential calculation and Fourier transformation of it
and then we can obtain the dynamic MTF curve of the optical system. The value of the curve at the Nyquist frequency is the most important parameter that reflects the image quality. We add push-scanning imaging and environmental effects to the static MTF of space camera and compare the MTF value with the dynamic MTF at Nyquist frequency. The comparison result can help us verify the accuracy of the calculating results and the feasibility of our method. (2011) Trans Tech Publications.
Study on medical X-ray coherent scatter imaging and processing based digital flat detector (EI CONFERENCE)
会议论文
OAI收割
3rd International Conference on BioMedical Engineering and Informatics, BMEI 2010, October 16, 2010 - October 18, 2010, Yantai, China
作者:
Li B.
;
Zhao J.
;
Li B.
;
Li B.
;
Liu J.
收藏
  |  
浏览/下载:34/0
  |  
提交时间:2013/03/25
It is introduced a novel imaging technique for medical diagnostic X-ray coherent scatter in this paper. A set of experimental equipment for X-ray coherent scatter imaging was set up with X-ray digital flat detector and medical diagnostic X-ray source. According to this equipment
the scatter images obtained are made of some circles with the same center. It is vital to calculate the energy template to classify the different samples. It is difficult to separate them using the traditional threshold method due to noise and overlapped shadow. In this paper
the image was transformed a binary image by using K-Means algorithm and Mathematical Morphology Methods. The effective region was extracted from the binary image inside the orthogonal energy projection space
then to calculate the centroid of rings. Consequently the curve of the energy distribution was built. The experiment results show that our method is reasonable and feasible. The technique will have wide foreground of application .Besides the imaging of human bone content
it can be used for various imaging of tissue and organs in biology. 2010 IEEE.