Particle tracking simulation. in the CSRe stochastic cooling system
期刊论文
OAI收割
CHINESE PHYSICS C, 2015, 卷号: 39, 页码: 8
作者:
Hu Xue-Jing
;
Jia Huan
;
Zhang Xiao-Hu
;
Wu Jun-Xia
;
Yuan You-Jin
  |  
收藏
  |  
浏览/下载:16/0
  |  
提交时间:2018/05/31
stochastic cooling
optical layout design
particle tracking
cooling rate
Design of reimaging F/1.0 long-wavelength infrared optical system (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2013/03/25
A reimaging F/1.0 long-wavelength infrared optical system is proposed. The design has a flexible opto-mechanical layout. The design process is as follows. Firstly
the catadioptric reimaging system consists of two reflecting mirrors and a relay lenses. Two reflecting mirrors make up of the first imaging system and are therefore free of chromatic aberrations
while low dispersion lenses were used in the reimaging system
so the optical system do not need achromatic design for a high image quality. Then
to correct high-order aberrations resulting from large relative aperture
more parameters need to be used with aspheric or diffractive surfaces due to modern optic technology development. Here
aspheric is selected for easily manufacture. Finally
the design is completed with the help of ZEMAX software. The effective focal length of the objective is 120mm and the field of view (FOV) is 4. The simulated final design shows adequate image quality and the modulation transfer function (MTF) is close to diffraction limit. The effect of the surrounding environmental temperature is analyzed using the concept of thermal defocusing
and the thermal compensation is discussed. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Design of high-speed low-noise pre-amplifier for CCD camera (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optoelectronic Materials and Devices for Detector, Imager, Display, and Energy Conversion Technology, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Zhang S.
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2013/03/25
Pre-amplifier circuit is critical for the noise performance of the high speed CCD camera. Its main functions are amplification and impedance transform. The high speed and low noise pre-amplifier of CCD camera is discussed and designed in this paper. The high speed and low noise operational amplifier OPA842 is adopted as the main part. The gain-set resistors for the amplifier are designed optimally. The different precision gain-set resistors are swept using Monte Carlo method. CCD video signal which has high DC offset voltage is AC coupled to the amplifier. The output signal of the amplifier is source terminated using 50 ohms matching resistor so as to transmit the video signal through coaxial cable. When the circuit works in high speed
the PCB will have important effect to circuit performance and can even cause the amplifier unstable due to the parasitic problem of PCB. So the parasitic model of the PCB is established and the PCB layout design issues are also presented. The design result shows that the pre-amplifier can be used in the camera whose pixel rate could be up to 40 MHz and its input referred noise density is about 3 nV/Hz 1/2. 2010 Copyright SPIE - The International Society for Optical Engineering.
Design and tolerance analysis of compensator for high order aspheric surface testing (EI CONFERENCE)
会议论文
OAI收割
2009 International Conference on Optical Instruments and Technology - Optoelectronic Measurement Technology and Systems, October 19, 2009 - October 22, 2009, Shanghai, China
作者:
Chen X.
;
Liu W.
;
Chen X.
;
Chen X.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
High accuracy is required in surface testing of 90nm nodal point lithography projecting lens. By comparing various aspheric surface testing methods
the structure layout of the compensator is a meniscus positive lens combined with a Plano-convex positive lens. The design results indicate that: primary and high order aberrations are balanced well
we adopt Offner null compensator to test the aspheric surface in the point diffraction interferometer at last. In this paper
MTF exceeds diffraction limit
an Offner compensator is presented on the base of the third order aberration theory to test concave aspheric surface
root-mean-square (RMS) of wave front error /167. The F-number of the system can achieve F/1.64. By the analysis of the process of aspheric surface testing with the designed system
the optical construction parameters of which is determined by introducing equal-quantities spherical aberration to compensate all orders of aspheric coefficients. The field of view of the system is 0.02
a loosen distribution of the tolerance was presented based on the accuracy of measuring apparatus. 2009 SPIE.
Research on shaftless fast-steering mirror used in a precision tracking-aiming system (EI CONFERENCE)
会议论文
OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Large Mirrors and Telescopes, July 8, 2007 - July 12, 2007, Chengdu, China
作者:
Wang Y.
;
Guo J.
;
Guo J.
;
Wang Y.
;
Wang Y.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
Based on the analysis of principle of tracking and aiming system
some important factors to design the structure of tracking-aiming system and the layout of optical system are discussed. Besides
the paper gives the present developing situation of fast-steering mirror at home and abroad
analyzes the advantages and disadvantages of FSM with axis
and presents a novel design of flexible axis FSM. The main axis of composite axis system is tracked by motor to drive the frame
and the sub-axis is tracked by voice coil motor (VCM) to drive FSM. The structure of FSM and designing principle of VCM are introduced
and the emulation analyses of inherent frequency and deformation under load of the FSM with software COSMOS are also given.
Design of dual-FOV refractive/diffractive LWIR optical system (EI CONFERENCE)
会议论文
OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Advanced Optical Manufacturing Technologies, July 8, 2007 - July 12, 2007, Chengdu, China
作者:
Wang L.-J.
;
Zhang J.-P.
;
Wang L.-J.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2013/03/25
An infrared-optical zoom system using binary element is proposed in this paper. The two main advantages of the zoom system introducing here are: bigger F-number and lower cost. The primary optical properties are: F/#=1
Second
Others
zoom ratio =1:4
binary element is used to correct the chromatical aberration by taking the advantage of negative dispersion characteristics and the cost of the system is lower than that of conventional ones with Zinc Selenide (Znse) material at the same level. In the binary element is rotational symmetric with one step which is easy to fabricate
in order to balance 5th spherical aberration
and dual field are 26.6 and 5.6respectively. Wider field of view is used for search and the smaller one is used for imaging details. This system uses un-cooled infrared detector with 320240 pixels and 45m pixel size. The F-number matches the sensitivity range of the detector array. Three aspects are considered during design process to make the system more satisfactory and more achievable. First
5th coma aberration and 5th astigmatic aberration
the manner of zoom is accomplished by exchanging tow lenses into the smaller field of view system layout. The lens exchange manner faces the requirement of simple system structure and good image quality in both focal points. It can also make the system more feasible in the alignment process than mechanical-zooming manner and optical-zooming manner
high-order asphere surfaces with 2th order to 10 th order are also hired in the system. Asphere surface is useful in compressing the system and improving optical system transmittance. This kind asphere surface is on industrial level featuring low cost and easy to fabricate. It is shown that good image quality can achieved by implementing five Germanium lenses and the transmittance of system is 72%. All aberrations are diffraction-limited
both spherical aberration and astigmatic aberration are corrected. When the field of view(FOV) is 26.6 and the focal length is 152mm
MTF at Nyquist frequency(11lp/mm) is great than 0.7. The spherical aberration is -0.0073. The coma aberration is 0.0978 and the astigmatic aberration is -0.013. When the field of view(FOV) is 5.6 and the focal length is 38mm
MTF at Nyquist frequency is great than 0.8 with spherical aberration -0.0046
the coma aberration 0.055 and astigmatic aberration 0.034.
光学元件波前分布对光束质量的影响研究
学位论文
OAI收割
作者:
徐林波
  |  
收藏
  |  
浏览/下载:52/0
  |  
提交时间:2018/12/26
波前畸变
Wavefront aberration
数值模拟
Simulation calculation
光束质量
Beam quality
光路设计