中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [5]
地理科学与资源研究所 [3]
生物物理研究所 [1]
采集方式
OAI收割 [9]
内容类型
会议论文 [5]
期刊论文 [4]
发表日期
2020 [2]
2018 [1]
2011 [2]
2010 [2]
2009 [1]
2005 [1]
更多
学科主题
Biochemist... [1]
筛选
浏览/检索结果:
共9条,第1-9条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
General solution to reduce the point spread function effect in subpixel mapping
期刊论文
OAI收割
REMOTE SENSING OF ENVIRONMENT, 2020, 卷号: 251, 页码: 19
作者:
Wang, Qunming
;
Zhang, Chengyuan
;
Tong, Xiaohua
;
Atkinson, Peter M.
  |  
收藏
  |  
浏览/下载:23/0
  |  
提交时间:2021/03/16
Remote sensing images
Subpixel mapping (SPM)
Supper-resolution mapping
Downscaling
Spectral unmixing
Point spread function (PSF)
Accuracy assessment
A Geostatistical Filter for Remote Sensing Image Enhancement
期刊论文
OAI收割
MATHEMATICAL GEOSCIENCES, 2020, 卷号: 52, 期号: 3, 页码: 317-336
作者:
Wang, Qunming
;
Tong, Xiaohua
;
Atkinson, Peter M.
  |  
收藏
  |  
浏览/下载:42/0
  |  
提交时间:2020/05/19
Remote sensing
Geostatistics
Image enhancement
Image filtering
Point spread function (PSF)
Enhancing spectral unmixing by considering the point spread function effect
期刊论文
OAI收割
SPATIAL STATISTICS, 2018, 卷号: 28, 页码: 271-283
作者:
Wang, Qunming
;
Shi, Wenzhong
;
Atkinson, Peter M.
  |  
收藏
  |  
浏览/下载:64/0
  |  
提交时间:2019/05/23
Land cover
Spectral unmixing
Soft classification
Point spread function (PSF)
Area-to-point-kriging (ATPK)
Astronomical image restoration through atmosphere turbulence by lucky imaging (EI CONFERENCE)
会议论文
OAI收割
3rd International Conference on Digital Image Processing, ICDIP 2011, April 15, 2011 - April 17, 2011, Chengdu, China
作者:
Zhao J.
;
Wang J.
;
Zhang S.
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2013/03/25
In this paper
we develop a lucky imaging system to restore astronomical images through atmosphere turbulence. Our system takes very short exposures
on the order of the atmospheric coherence time. The rapidly changing turbulence leads to a very variable point spread function (PSF)
and the variability of the PSF leads to some frames having better quality than the rest. Only the best frames are selected
aligned and co-added to give a final image with much improved angular resolution. Our system mainly consists of five parts: preprocessing
frame selection
image registration
image reconstruction
and image enhancement. Our lucky imaging system has been successfully applied to restore the astronomical images taken by a 1.23m telescope. We have got clear images of moon surface and Jupiter
and our system can be demonstrated to greatly improve the imaging resolution through atmospheric turbulence. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Research on image restoration of Roll-Swing imaging seeker (EI CONFERENCE)
会议论文
OAI收割
3rd IEEE International Conference on Advanced Computer Control, ICACC 2011, January 18, 2011 - January 20, 2011, Harbin, China
作者:
Zhang H.
;
Zhang H.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
To achieve a correct image receiving for Roll-Swing imaging seeker
the mechanism and imaging process is analyzed. The causes of image rotation are discussed. The influence of the frame encoders' precision on imaging de-rotation quality is analyzed. The Roll-Swing imaging seeker is designed for high-speed aerocraft
thus the received images are greatly degraded due to atmospheric turbulence. A new method of image restoration is proposed for turbulence-degraded images in this paper. The method is to get point spread function (PSF) based on the estimation of optical transfer function (OTF) according to the optical system design simulation. Finally
to obtain the restored image
constrained least squares filtering is used with the known PSF. The experiment results indicate that the new restoration method has a favorable effect to satisfy requirement of the automatic target recognition. 2011 IEEE.
Mechanism of STED microscopy and analysis of the factors affecting resolution (EI CONFERENCE)
会议论文
OAI收割
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
Yang P.
;
Ai H.
收藏
  |  
浏览/下载:23/0
  |  
提交时间:2013/03/25
Stimulated emission depletion (STED) microscopy exploits nonlinear saturable optical transition of fluorescent molecules
allowed to overcome Abbe's diffraction-limit and provides diffraction-unlimited resolution in far-field optical microscopy. We elaborate the mechanism of STED and the conditions of depletion. The formula of STED microcopy resolution is deduced through effective point spread function (E-PSF). The STED system resolution is mainly dominated by the quality of the fluorescence depletion patterns in the focal plane. The depletion pattern is mainly affected by STED beam intensity
polarization
phase plate
primary aberrations
STED pulse shape
pulse duration and delay time. In this paper
we found related models and simulate the relationship between the depletion patterns and the parameters
and put forward effective approach to enhance the system resolution. 2010 SPIE.
Remote sensing image restoration using estimated point spread function (EI CONFERENCE)
会议论文
OAI收割
2010 International Conference on Information, Networking and Automation, ICINA 2010, October 17, 2010 - October 19, 2010, Kunming, China
作者:
Yang L.
;
Yang L.
收藏
  |  
浏览/下载:32/0
  |  
提交时间:2013/03/25
In order to reduce image blur caused by the degradation phenomenon in the imaging process
the acquired images of the space remote sensing camera are restored. First
the frequency-domain notch filter is adopted to remove strip noises in the images. Then degradation function
which is referred to as the point spread function (PSF) of the imaging system is estimated using the knife-edge method. To improve the accuracy of the estimation
the estimated PSF is adjusted with Gaussian fitting. Finally
the images are restored by Wiener filtering with the fitted PSF. The restoration results of the remote sensing images show that almost all strip noises are eliminated by the notch filter. After denoising and restoration
the variance of the remote sensing image worked with in this paper increases 30.979 and the gray mean gradient increases 3.312. Due to Gaussian fitting
the accuracy of the PSF estimation is heightened. Image restoration with the final PSF is benefit to interpreting and analyzing the remote sensing images. After restoration
the contrasts of the restored images are increased and the visual effects become clearer. 2010 IEEE.
Introduction to Theories of Several Super-resolution Fluorescence Microscopy Methods and Recent Advance in The Field
期刊论文
OAI收割
PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2009, 卷号: 36, 期号: 12, 页码: 1626-1634
Lue ZhiJian
;
lu jingze
;
陆敬泽
;
Wu YaQiong
;
Chen Liangyi
;
陈良怡
收藏
  |  
浏览/下载:102/0
  |  
提交时间:2013/12/25
super-resolution fluorescence microscopy
point spread function (PSF)
photoactivated localization microscopy (PALM)
stochastic optical reconstruction microscopy (STORM)
stimulated emission depletion (STED)
saturated structure illumination microscopy (SSIM)
A new method of image reconstruction with high resolution in X-ray coded aperture imaging (EI CONFERENCE)
会议论文
OAI收割
Laser-Generated, Synchrotron, and Other Laboratory X-Ray and EUV Sources, Optics, and Applications II, August 2, 2005 - August 4, 2005, San Diego, CA, United states
作者:
Sun Y.
;
Sun Y.
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2013/03/25
In the processing diagnosis of the inertia confinement fusion (ICF)
the ring coded aperture imaging technique is applied in order to gain high space and time resolutions simultaneously. The key of acquiring high spatial resolution is how to obtain a point spread function of an imaging system. The common method is the firsthand projection method which is an approximate one. The x-ray diffraction effect is neglected in the method
so the resolution of reconstructed image is decreased. We have derived the point spread function (PSF) of the ring coded aperture from scalar diffraction theory. And the Wiener filter is fabricated on the basis of the PSF. In National Key Laboratory of Laser Fusion
at China Academy of Engineering Physics
the imaging experiment on the diagnosis of ICF is completed using the ring coded aperture plate with inner diameter d1 = 250m and outer diameter d2 = 260m . The obtained coded image is processed by the Wiener filter which diffractive effect is considered. The processed results have shown that resolution and modulation contrast of acquired image are evidently better than the results obtained by the firsthand projection method.