中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共5条,第1-5条 帮助

条数/页: 排序方式:
Quantitative simulating experiment of atmospheric turbulence scintillation for light field imaging 会议论文  OAI收割
Kunming, China, 2021-12-07
作者:  
Cheng, Zhiyuan;  Ma, Qing;  Li, Zhiguo;  Xia, Aili;  Ji, Zhou
  |  收藏  |  浏览/下载:116/0  |  提交时间:2022/04/27
Reproduction of the Sedimentary Disturbance Phenomenon of the Diexi Ancient Landslide-Dammed Lake under Earthquake 期刊论文  OAI收割
Journal of Mountain Science, 2015, 卷号: 12, 期号: 5, 页码: 1181-1188
作者:  
WEI Yu-feng;  WANG Xiao-qun;  SHENG Man;  ZHOU Zhou;  YUAN Yong
收藏  |  浏览/下载:72/0  |  提交时间:2015/09/22
The calibration of faint simulation star magnitude based on single photon count technique (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Advances in Imaging Detectors and Applications, June 17, 2009 - June 19, 2009, Beijing, China
作者:  
Xu S.-Y.;  Guo J.;  Guo J.
收藏  |  浏览/下载:33/0  |  提交时间:2013/03/25
A calibration method of faint star magnitude of the star scene simulation device is proposed in this paper. In the research of simulation star magnitude  luminometers and CCD devices are the general calibration devices which are used to measure the illumination intensity and calibrate its magnitude. But if the simulation magnitude is only sixth magnitude  its illumination intensity is only 1.010-8 Lux. This illumination intensity level is the lowest illumination intensity that the commercial luminometer can detect. Hence the simulation star magnitude lower than six magnitude cannot be calibrated by luminoters. Likewise CCD devices also need an additive cooler in this case. When the single photon characteristic is presented due to the low luminosity of simulating light sources  the simulation star magnitude can be calibrated by detecting its photon flux of radiation with the method of single photon count. In this paper the detection principle of single photon based on a compact designed PMT detecting of the radiation level of simulation star magnitude is advanced. Especially a spectrum match method is proved theoretically to be an effective means for selecting PMT photosensitive type. In the case of the detection object of the simulation star in visible wavelength  a analysis indicates that the material of tri-alkali cathode materials its best choice after being compared the Signal-to-Noise of photon detector of several PMT photosensitive materials based on the different spectrum match ratio of different object light sources and different cathode materials. An experiment is employed to show the relationship of control voltage of PMT and its dark counter  the relationship of the environment temperature of PMT and its dark counter  which proves its only decades of CPS at room temperature. The so low dark counter avoids a bulky cooler and is convenient for installing it on the star scene simulation equipment. Finally in the experiment of calibrating the simulation star magnitudes the ability of its calibration is confirmed to reaches up to 12m  meanwhile its calibration error is within 0.2m. 2009 SPIE.  
Design of a scene simulator in land-based aerospace lab with the man-made light source system based on quantum theory (EI CONFERENCE) 会议论文  OAI收割
Optoelectronic Devices and Integration II, November 12, 2007 - November 15, 2007, Beijing, China
作者:  
Fang W.;  Yi W.
收藏  |  浏览/下载:29/0  |  提交时间:2013/03/25
The paper presents a method with the technique of combination filtering of spectrum and the technique of DSP control for the simulation and recognition of the spontaneously lightening object and stellar map in the universe. The magnitude and the spectrum of a star can be simulated in a wide dynamic range. We established the mathematical models of the Vega's visible light spectrum and luminous flux density. Tungsten-halogen lamp as a light source is used to fit the linear light of the spontaneously lightening object in the universe. Through the experiment  it shows that the more sub-channels there are while filtering spectrum in the visible spectrum  and the more degrees the variable neutral density filters and the narrow-band attenuators have  more close to the actual spectrum the simulated spectrum is. It is proved that using the PID technique is beneficial to the output of the accurate and steady radiation from the light sources. The experiment shows that the using of this method can get perfect result in fitting and simulating the spectrum  magnitude and the stellar map of the spontaneously lightening object . The analysis of the consistent result and the experimental error is also discussed in detail in this paper.  
Research on the radiometric calibration of TDI CCD remote camera (EI CONFERENCE) 会议论文  OAI收割
ICO20: Illumination, Radiation, and Color Technologies, August 21, 2005 - August 26, 2005, Changchun, China
Liu Y.-X.; Hao Z.-H.
收藏  |  浏览/下载:18/0  |  提交时间:2013/03/25