中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共3条,第1-3条 帮助

条数/页: 排序方式:
Data normalization of single camera visual measurement network system (EI CONFERENCE) 会议论文  OAI收割
2012 International Conference on Information Technology and Management Innovation, ICITMI 2012, November 10, 2012 - November 11, 2012, Guangzhou, China
作者:  
Zhang Y.-C.;  Zhou J.
收藏  |  浏览/下载:23/0  |  提交时间:2013/03/25
With the development of visual measurement system  Normalize the measured coordinates into the same world coordinate system  Apply in the three coordinate measuring machine(CMM) to have the simulation experiment  So the data normalization has the advantage of more high precision. (2013) Trans Tech Publications  the visual measurement system of single camera which applied in the imaging theory of optical feature points  then get the global data  the result indicates that the maximum absolute tolerance between the normalization coordinates via the center of point set and the ones measured by CMM directly is 0.058mm  Switzerland.  it has been widespread used in the modern production. Due to the limit of the environment in scene  and achieve the overall measurement  the visual measurement system of single camera could not measure the shield between the measured objects each other. Focus on this problem  But the one between the coordinate repeatedly measured at the position of one network control point is 0.066mm  present a kind of the the knowledge of measurement network based on the visual measurement of single camera  set up the measurement network system via the multi-control points. Measure the optical feature points in every network control point via the visual measurement system of single camera  
The structure of background-error covariance in a four-dimensional variational data assimilation system: single-point experiment 期刊论文  iSwitch采集
Advances in atmospheric sciences, 2010, 卷号: 27, 期号: 6, 页码: 1303-1310
作者:  
Liu Juanjuan;  Wang Bin;  Wang Shudong
收藏  |  浏览/下载:37/0  |  提交时间:2019/05/10
Study of microsphere plate photomultiplier tube (EI CONFERENCE) 会议论文  OAI收割
ICO20: Remote Sensing and Infrared Devices and Systems, August 21, 2005 - August 26, 2005, Changchun, China
作者:  
Wang X.;  Li Y.;  Li Y.;  Li Y.;  Li Y.
收藏  |  浏览/下载:32/0  |  提交时间:2013/03/25
The photomultiplier tube (PMT) that can work in different wavelength is an important detector device in remote sense technology. Microsphere plate using glass beads 50to 70m in diameter sintered together is the core component of the microsphere plate photomultiplier tube It is a novel two-dimension electron multiplier. The electrons gain for a single plate is about 1017 and do not have the phenomenon of ion-feedback. Furthermore the fabrication process is very easy. In this paper  much interest was put on the microsphere plate photomultiplier tube. Based on the analyses from the theory and the experiment result  we point out the key technology for fabricating PMT is how to obtain glass beads with narrow range in diameter and how to sinter the glass beads with a sufficient pylome. Factors affect the gradating technology and sintering process along with the solution to them is presented. In the last  the structure scheme and technological characteristic for fabricating microsphere plate photomultiplier tube were given. The pulse rising-time of MSP-PMT is below 400ps suitable to the detection of high-speed pulse. As easy to be fabricated and has great advantage over MCP multiplier in the ratio of performance to price  the microsphere plate photomultiplier tube is a promising dim-light detector.