中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [3]
力学研究所 [2]
数学与系统科学研究院 [1]
中国科学院大学 [1]
工程热物理研究所 [1]
采集方式
OAI收割 [7]
iSwitch采集 [1]
内容类型
期刊论文 [5]
会议论文 [3]
发表日期
2022 [2]
2019 [1]
2016 [1]
2012 [1]
2009 [1]
2008 [2]
更多
学科主题
筛选
浏览/检索结果:
共8条,第1-8条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
作者升序
作者降序
Analysis of thermal stress, fatigue life and allowable flux density for the molten salt receiver in solar power tower plants
期刊论文
OAI收割
INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2022, 卷号: 17, 页码: 1385-1398
作者:
Luo, Yan
;
Li, Gen
;
Lu, Tao
;
Wang, Ruixing
  |  
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2023/02/07
local weather data
incident heat flux distribution
allowable flux density
fatigue life analysis
solar power tower receiver
Multi-objective robust optimization of a solar power tower plant under uncertainty
期刊论文
OAI收割
ENERGY, 2022, 卷号: 238, 页码: 11
作者:
Luo, Yan
;
Wang, Zhiyuan
;
Zhu, Jiamin
;
Lu, Tao
;
Xiao, Gang
  |  
收藏
  |  
浏览/下载:96/0
  |  
提交时间:2021/11/01
Solar power tower plant system
Uncertainty propagation
Multi-objective robust optimization
Global sensitivity analysis
Levelized cost of energy
An annular compound parabolic concentrator used in tower solar thermal power generation system
期刊论文
OAI收割
SOLAR ENERGY, 2019, 卷号: 188, 页码: 1256-1263
作者:
Huang, Yuan
;
Ma, Xiaoyu
;
Rao, Changhui
;
Liu, Xincheng
;
He, Rui
  |  
收藏
  |  
浏览/下载:58/0
  |  
提交时间:2020/01/10
Tower solar thermal power generation
Power generation efficiency
Concentration ratio
Annular compound parabolic concentrator
Thermal analysis of a heat pipe solar central receiver for concentrated solar power tower
期刊论文
iSwitch采集
Applied thermal engineering, 2016, 卷号: 102, 页码: 952-960
作者:
Liao, Zhirong
;
Faghri, Amir
收藏
  |  
浏览/下载:39/0
  |  
提交时间:2019/05/09
Central receiver
Heat pipe
Molten salt
Concentrated solar power tower
Design of heliostats field for the scale of 1MW solar power tower plant (EI CONFERENCE)
会议论文
OAI收割
2012 Asia-Pacific Power and Energy Engineering Conference, APPEEC 2012, March 27, 2012 - March 29, 2012, Shanghai, China
作者:
Zhang H.
;
Wang Z.
;
Wang Z.
;
Zhang H.
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2013/03/25
The development in basic technology and market strategy of solar thermal power techniques is booming rapidly due to the limited fossil resources and severe environmental problems all over the world. In this paper
the design method of heliostats field for the scale of 1MW solar power tower plant with latitude of 40.4N at the design point of the noon of spring equinox is introduced
which uses the multiplication of three efficiencies of cosine
atmospheric transmittance and intercept as the preliminary boundary limit to locate heliostats
while the spacing between heliostats is set not only for less shading and blocking
but also for the availability of installation and maintenance of heliostats. Furthermore
its optical performance tested by the software HFLD
is quite good
which has annual average efficiency of 71.36% and design point efficiency of 80%. 2012 IEEE.
DESIGN OF THE FIRST CHINESE 1 MW SOLAR-POWER TOWER DEMONSTRATION PLANT
期刊论文
OAI收割
INTERNATIONAL JOURNAL OF GREEN ENERGY, 2009, 卷号: 6, 期号: 5, 页码: 414-425
作者:
Wei Han
;
Jin Hongguang
;
Su Jianfeng
;
Lin Rumou
;
Wang Zhifeng
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2015/12/18
Solar-power tower
Two-stage thermal energy storage
Operating mode
Optimization
Optimization procedure for design of heliostat field layout of a 1MWe solar tower thermal power plant (EI CONFERENCE)
会议论文
OAI收割
Solid State Lighting and Solar Energy Technologies, November 12, 2007 - November 14, 2007, Beijing, China
作者:
Zhang H.
;
Zhang H.
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2013/03/25
A procedure for designing and optimizing heliostat field layout of solar tower thermal power plant is developed. The ray tracing is used for the calculation of the optical efficiency of field. The mathematical theory of the calculation is derived. The parametric search algorithm
which allows variation of the field parameters within a specified range
is used for the optimization of field. The field layout is made automatically according to the no-blocking loss condition and the heliostats are located at the positions where the annual incident cosine value is higher. In this way
the blocking and cosine losses are lowered. Because the optimization of the distance between fore-and-aft two rows of heliostat is avoided
the computer time is reduced effectively. Using this procedure the heliostat field of a 1MWe solar tower power plant was designed. Four modes of layout including North-South cornfield
North-South stagger
Radial cornfield and Radial stagger were experimented and optimized respectively. The comparison of the field efficiency for the four optimized results was made. It is concluded that the North-South cornfield layout is the optimal decision for the 1MWe solar tower power plant.
Shape and alignment measurement of the heliostat by laser deflectometry (EI CONFERENCE)
会议论文
OAI收割
Optical Modeling and Measurements for Solar Energy Systems II, August 13, 2008 - August 14, 2008, San Diego, CA, United states
作者:
Liu H.
;
Zhang H.
;
Zhang H.
;
Liu H.
;
Liu H.
收藏
  |  
浏览/下载:18/0
  |  
提交时间:2013/03/25
In the solar tower thermal power generation system
such apparatus and corresponding software packages are developed. With the help of these two apparatus
(hexagon)
the precision of the slope angle of the heliostat is the major factor
the heliostat of 1002
for the 1MWe solar tower power plant in Beijing are measured and connected successfully.
which influences the efficiency of the system
consisting of 55 mirror facets of 1.8182 m2
consequently
this angle should be tested accurately. In this paper
the methods based on laser deflectometry are proposed to measure the shape error of the mirror facet and the connected error of the facets