氯代和溴代多环芳烃的环境污染特征和来源研究
学位论文
OAI收割
北京: 中国科学院生态环境研究中心, 2018
作者:
金蓉
  |  
收藏
  |  
浏览/下载:153/0
  |  
提交时间:2019/07/04
氯代和溴代多环芳烃
Chlorinated And Brominated Polycyclic Aromatic Hydrocarbons
Analytical Method
Haze
Atmosphere
Source.
分析方法
雾霾
大气
污染源。
Software for Small-scale Robotics: A Review
期刊论文
OAI收割
International Journal of Automation and Computing, 2018, 卷号: 15, 期号: 5, 页码: 515-524
作者:
Tobias Tiemerding
;
Sergej Fatikow
  |  
收藏
  |  
浏览/下载:16/0
  |  
提交时间:2021/02/23
Robotic control
software engineering
micro/nano robotics
artificial intelligence (AI)
machine learning (ML)
open source.
Design of programmable near infrared cold light source (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electronics and Optoelectronics, ICEOE 2011, July 29, 2011 - July 31, 2011, Dalian, China
作者:
Fu Q.
;
Wang B.
;
Wang B.
;
Wang R.
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2013/03/25
In the near infrared spectroscopy
detector of Charge-coupled Device requires very high stability for light source. We design the cold light source in the measurement of near infrared spectroscopy. Cold light source consists of high-power op amp OPA549 high current constant current source and proportion integral differential (PID) control algorithm. As is shown in the experimental results
the method is better
the overshoot is very small
the stability is excellent in the process of soft-start. While light intensity was able to meet the requirements of near-infrared instruments to measure. 2011 IEEE.
Study on medical X-ray coherent scatter imaging and processing based digital flat detector (EI CONFERENCE)
会议论文
OAI收割
3rd International Conference on BioMedical Engineering and Informatics, BMEI 2010, October 16, 2010 - October 18, 2010, Yantai, China
作者:
Li B.
;
Zhao J.
;
Li B.
;
Li B.
;
Liu J.
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2013/03/25
It is introduced a novel imaging technique for medical diagnostic X-ray coherent scatter in this paper. A set of experimental equipment for X-ray coherent scatter imaging was set up with X-ray digital flat detector and medical diagnostic X-ray source. According to this equipment
the scatter images obtained are made of some circles with the same center. It is vital to calculate the energy template to classify the different samples. It is difficult to separate them using the traditional threshold method due to noise and overlapped shadow. In this paper
the image was transformed a binary image by using K-Means algorithm and Mathematical Morphology Methods. The effective region was extracted from the binary image inside the orthogonal energy projection space
then to calculate the centroid of rings. Consequently the curve of the energy distribution was built. The experiment results show that our method is reasonable and feasible. The technique will have wide foreground of application .Besides the imaging of human bone content
it can be used for various imaging of tissue and organs in biology. 2010 IEEE.
Research on the laboratory radiometric calibration of the thermal imager (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Wang J.
;
Liu Y.
;
Liu Y.
;
Liu Y.
;
Sun Q.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
The radiometric calibration of the thermal imager was investigated to build the relationship between the input radiance and the digital output to realize the temperature measurement. The radiometric calibration was implemented in the State Key Laboratory of Applied Optics. A standard black body source was served as radiation source. The response of the thermal imager to the input radiance was tested for different gains. The experimental results show that the average grey level of the output imaging is linear dependence of the input radiance. Because the radiance in the receiving wave range of the thermal imager is linear with the black body's temperature based on Planck's law of radiation
the average grey level of the output image is also linear with the black body's temperature after fitting a curve to the experiment data points. Then the relationship of the response and the gain was studied when the black body's temperature kept constant. The preliminary analysis of calibration data shows that the response of the thermal imager is linear and the average grey value of the image is directly proportion to the gain. According to the experimental results
the reference gains and the dynamic range of temperature measurement were obtained. Finally
the uncertainty influencing the calibration results was analyzed
the analysis shows the maximal uncertainty is 5.2%
which can meet the calibration requirement less than 10%. 2010 Copyright SPIE - The International Society for Optical Engineering.
Micro assembled fourier transform spectrometer (EI CONFERENCE)
会议论文
OAI收割
4th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, November 19, 2008 - November 21, 2008, Chengdu, China
作者:
Liang J.-Q.
;
Zhang J.
;
Zhang J.
;
Zhang J.
;
Wang B.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
With the trend of minimization of Fourier transform spectrometer (FTS) which is particularly pronounced in many applications
a model of a micro FTS with no moving parts is proposed and analyzed. During analyzng
the gradients which mainly introduce phase error are accounted. Based on these assumptions and the improved Mertz phase correcting method
the spectrum of signal is simulated with real extended light source. The resolution can be up to 3.43nm@800nm
with high signal-to-noise ratio (SNR) limiting resolving ability 6.8dB. In addition
the fabrication method of components are illuminated and demonstrated
which can not only make it bear some advantages over conventional micro dispersive spectrometers
but also afford some new concepts on the design of spectrometers with improved performance. 2009 SPIE.
The application study on building materials with computer color quantification system (EI CONFERENCE)
会议论文
OAI收割
ICO20: Illumination, Radiation, and Color Technologies, August 21, 2005 - August 26, 2005, Changchun, China
作者:
Yu H.
;
Li Z.
;
Li Z.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
The first impression of any building to a person is its exterior and decoration
therefore
at the same time
and therefore the quality of decoration project shows the more important position in building project. A lot of projects produce quality problem because of the material color difference
how to grasp and control the color change of building materials
the color difference problem laying stone materials is also studied in this paper
which exists universally at the common project
and carry out color quantification
and the solution scheme has been given using this system.
and is often found at the high-grade decoration
it has the very important meaning. According to the color theory
a computer vision system used in color quantification measurement is established
the standard illuminant A is selected as the light source. In order to realize the standardization of color evaluation
the mutual conversion between RGB and XYZ color space is studied
which is realized by the BP network. According to the colorimetry theory
the computer program is compiled in order to establish the software system
and realize the color quantitative appraisement in whole color gamut. LCH model is used at quantifying the color of building materials
and L*a*V model is used at comparing the color change. If the wooden floor is selected and laid improperly during family fitment
it is easy to present "flower face". The color also arises greater discrepancy using the laths of same tree. We can give the laying scheme using the color quantification system
Energy transfer processes on both Er+ ion concentration and excitation densities in Yb3+-Er3+ codoped LaF3 matrix (EI CONFERENCE)
会议论文
OAI收割
作者:
Zhang J.
;
Wang Y.
;
Wang Y.
;
Wang Y.
;
Zhang J.
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2013/03/25
The effects of both Er3+ ion concentration and excited density upon frequency upconversion fluorescence emissions in Er3+/Yb 3+-codoped LaF3 powder are investigated. The results reveal that a higher Er3+ concentration can induce not only upconversion emission enhancements but also the changes among the relative intensities of the 407
519
539 and 651 nm radiation transitions as the samples are excited within the ranges of 20 to 700 mW with 978 nm laser diode (LD) as an excitation source. The changes are described by a schematic level model with the cross-relaxation processes between Er3+ ions and a series of dynamic equations that take into account the population of temperature dependent in Er3+. 2006 Elsevier B.V. All rights reserved.
The effect of transparent film on its surface 3-D mapping by using vertical scanning white light interferometer (EI CONFERENCE)
会议论文
OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
Wu X.
;
Lei F.
;
Yatagai T.
收藏
  |  
浏览/下载:18/0
  |  
提交时间:2013/03/25
We have investigated the effect of transparent thin film while mapping its surface profile by using vertical scanning white light interferometer. Our theory analysis showed that multiple reflections taking place within the transparent thin film result in an extra phase change. The simulation and experiment results revealed that this extra phase change is also related to the thickness of thin film
the numerical number of microscope interferometer objective and the spectral distribution of light source. As a result of extra phase change
the interferogram has some deviation in its shape or two interference fringes may appears while the thickness of thin film is large.
Numerical analysis and experimental research of output performance for Yb3+-doped double-clad fiber lasers (EI CONFERENCE)
会议论文
OAI收割
High-Power Lasers and Applications III, November 8, 2004 - November 11, 2004, Beijing, China
作者:
Wang G.
;
Gao Y.
;
Li Y.
;
Li Y.
;
Li Y.
收藏
  |  
浏览/下载:16/0
  |  
提交时间:2013/03/25
In this paper
numerical analysis was investigated for the double-clad fiber lasers and experimental study on the Yb3+-doped double-clad fiber lasers was performed. The results shown that the output power increased monotonically with absorbed power
and in lossy cavity the output power is less than in the lossless cavity. The output power decreases for the lossy fiber with the reflectivity of output coupler. There was an optimum fiber length to reach a maximum output and the optimum length was mainly dependent on the loss coefficient. In experiment we obtained a output power of 21.6W
slope efficiency of 54% by using Yb3+-doped double-clad fiber and 40W LD pump source.