中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共6条,第1-6条 帮助

条数/页: 排序方式:
Study of experimental design and Response Surface method for surrogate model of computational simulation (EI CONFERENCE) 会议论文  OAI收割
2nd Annual Conference on Electrical and Control Engineering, ICECE 2011, September 16, 2011 - September 18, 2011, Yichang, China
Xi R.; Jia H.; Xiao Q.
收藏  |  浏览/下载:21/0  |  提交时间:2013/03/25
While the high-precision simulation is widely used in science and technology  Design of Experiment (DOE) based on Response Surface (RS) method can be employed in surrogate model to reduce the cost and error. In order to illustrate the relationship between parameters and response features  several DOE methods and Response Surface (RS) method are studied. The author used polynomial regression and RBF neural network based on orthogonal array to build a rocket aerodynamic discipline surrogate model respectively which proved their feasibility. From the results of the test case  conclusion is drawn that characteristic as well as acclimatization of DOE methods and different approximation should be considered for different issues  so the factors of cost and accuracy could reach a balance synthetically. 2011 IEEE.  
The effectiveness of real-time embedded software testing (EI CONFERENCE) 会议论文  OAI收割
2011 9th International Conference on Reliability, Maintainability and Safety: Safety First, Reliability Primary, ICRMS'2011, June 12, 2011 - June 15, 2011, Guiyang, China
Zhang B.; Shen X.
收藏  |  浏览/下载:32/0  |  提交时间:2013/03/25
CR image filter methods research based on wavelet-domain hidden markov models (EI CONFERENCE) 会议论文  OAI收割
ICO20: Optical Information Processing, August 21, 2005 - August 26, 2005, Changchun, China
作者:  
Wang J.-L.;  Wang J.-L.;  Li D.-Y.;  Wang Y.-P.
收藏  |  浏览/下载:18/0  |  提交时间:2013/03/25
In the procedure of computed radiography imaging  we should firstly get across the characters of kinds of noises and the relationship between the image signals and noises. Based on the specialties of computed radiography (CR) images and medical image processing  we have study the filtering methods for computed radiography images noises. On the base of analyzing computed radiography imaging system in detail  the author think that the major two noises are Gaussian white noise and Poisson noise. Then  the different relationship of between two kinds of noises and signal were studied completely. By considering both the characteristics of computed radiography images and the statistical features of wavelet transformed images  a multiscale image filtering algorithm  which based on two-state hidden markov model (HMM) and mixture Gaussian statistical model  has been used to decrease the Gaussian white noise in computed images. By using EM (Expectation Maximization) algorithm to estimate noise coefficients in each scale and obtain power spectrum matrix  then this carried through the syncretized two Filter that are IIR(infinite impulse response) Wiener Filter and HMM  according to scale size  and achieve the experiments as well as the comparison with other denoising methods were presented at last.  
The study on the near infrared spectrum technology of sauce component analysis (EI CONFERENCE) 会议论文  OAI收割
ICO20: Optical Information Processing, August 21, 2005 - August 26, 2005, Changchun, China
作者:  
Li S.;  Wang C.;  Chen X.;  Chen X.;  Chen X.
收藏  |  浏览/下载:36/0  |  提交时间:2013/03/25
The author  Shangyu Li  engages in supervising and inspecting the quality of products. In soy sauce manufacturing  quality control of intermediate and final products by many components such as total nitrogen  saltless soluble solids  nitrogen of amino acids and total acid is demanded. Wet chemistry analytical methods need much labor and time for these analyses. In order to compensate for this problem  we used near infrared spectroscopy technology to measure the chemical-composition of soy sauce. In the course of the work  a certain amount of soy sauce was collected and was analyzed by wet chemistry analytical methods. The soy sauce was scanned by two kinds of the spectrometer  the Fourier Transform near infrared spectrometer (FT-NIR spectrometer) and the filter near infrared spectroscopy analyzer. The near infrared spectroscopy of soy sauce was calibrated with the components of wet chemistry methods by partial least squares regression and stepwise multiple linear regression. The contents of saltless soluble solids  total nitrogen  total acid and nitrogen of amino acids were predicted by cross validation. The results are compared with the wet chemistry analytical methods. The correlation coefficient and root-mean-square error of prediction (RMSEP) in the better prediction run were found to be 0.961 and 0.206 for total nitrogen  0.913 and 1.215 for saltless soluble solids  0.855 and 0.199 nitrogen of amino acids  0.966 and 0.231 for total acid  respectively. The results presented here demonstrate that the NIR spectroscopy technology is promising for fast and reliable determination of major components of soy sauce.  
Research of on-axis tracking technology based on equal acceleration model (EI CONFERENCE) 会议论文  OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
作者:  
Zhao J.;  Li W.;  Li W.
收藏  |  浏览/下载:16/0  |  提交时间:2013/03/25
机载SAR与TM图像复合评估洪涝灾情 期刊论文  OAI收割
遥感信息, 1995, 期号: 2, 页码: 32-33+47
戴昌达,唐伶俐,江平,刘建波,李安,寇连群,潘京明