中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共8条,第1-8条 帮助

条数/页: 排序方式:
Energy Balance-Based SWAT Model to Simulate the Mountain Snowmelt and Runoff – Taking the Application in Juntanghu Watershed (China) as an Example 期刊论文  OAI收割
Journal of Mountain Science, 2015, 卷号: 12, 期号: 2, 页码: 368-381
MENG Xian-Yong; YU Dan-Lin; LIU Zhi-Hui
收藏  |  浏览/下载:34/0  |  提交时间:2015/03/24
Analysis of zenith pass problem and tracking strategy design for roll-pitch seeker (EI CONFERENCE) 会议论文  OAI收割
作者:  
Jiang H.
收藏  |  浏览/下载:17/0  |  提交时间:2013/03/25
Roll-pitch seeker is currently applied in particular missiles. There is a stubborn problem called zenith pass problem while roll-pitch seeker is used. Analysis of the zenith pass problem which always results in loss of target is presented in this paper. Based on the analysis result  tracking strategy is carried out to deal with zenith pass problem. To prove the validity of tracking strategy  a practical roll-pitch seeker was accomplished. Model identification and common PID controllers for the physical roll-pitch seeker are taken on  after that  both disadvantages derived from zenith pass problem in tracking process and meliorated phenomenons by the tracking strategy are shown. It is concluded that the tracking strategy designed for solving the zenith pass problem is efficient. 2011 Elsevier Masson SAS. All rights reserved.  
Aircraft flight simulation with landing gear based on multi-domain modeling technology (EI CONFERENCE) 会议论文  OAI收割
2012 2nd International Conference on Computer Application and System Modeling, ICCASM 2012, July 27, 2012 - July 29, 2012, Shenyang, China
作者:  
Li M.
收藏  |  浏览/下载:16/0  |  提交时间:2013/03/25
Establishment of airplane flight model and simulation analysis of landing behavior (EI CONFERENCE) 会议论文  OAI收割
2nd Annual Conference on Electrical and Control Engineering, ICECE 2011, September 16, 2011 - September 18, 2011, Yichang, China
作者:  
Li L.;  Li M.
收藏  |  浏览/下载:25/0  |  提交时间:2013/03/25
This paper create a high fidelity plant model of an aircraft landing gear to inclusion into a full aircraft flight simulation for accurately analyzing the performance and influence of landing gear system. The use of domain specific modeling software enables detailed modeling of the physics and facilitates accurate computational simulation of the flight dynamic  aerodynamic  landing gear dynamic and mechanical loads that occur when the landing gear are deployed and retracted during landing and take-off operations. The parameter design space is easily searched by considering a number of different landing scenarios including touching down on one wheel first  to optimize the design. The simulation results show that the aircraft landing gear system mathematical model established appropriately reflects the change of force and moment in the process of taking off and landing  and it is actual in the physical process. 2011 IEEE.  
Application of high-precision fuzzy control alorithm with self-regulation factor in RF hyperthermia system (EI CONFERENCE) 会议论文  OAI收割
6th International Conference on Machine Learning and Cybernetics, ICMLC 2007, August 19, 2007 - August 22, 2007, Hong Kong, China
Wang B.-D.; Chen Y.-Y.; Jiang C.-H.
收藏  |  浏览/下载:33/0  |  提交时间:2013/03/25
Study on color difference estimation method of medicine biochemical analysis (EI CONFERENCE) 会议论文  OAI收割
ICO20: Illumination, Radiation, and Color Technologies, August 21, 2005 - August 26, 2005, Changchun, China
作者:  
Zhou Y.;  Zhou F.;  Wang C.
收藏  |  浏览/下载:33/0  |  提交时间:2013/03/25
The biochemical analysis in medicine is an important inspection and diagnosis method in hospital clinic. The biochemical analysis of urine is one important item. The Urine test paper shows corresponding color with different detection project or different illness degree. The color difference between the standard threshold and the test paper color of urine can be used to judge the illness degree  therefore  it can be used in hospital  so that further analysis and diagnosis to urine is gotten. The color is a three-dimensional physical variable concerning psychology  the estimation method of color difference in urine test can have better precision and facility than the conventional test method with one-dimensional reflectance  calibrating organization and family  while reflectance is one-dimensional variable  it can make an accurate diagnose. The digital camera is easy to take an image of urine test paper and is used to carry out the urine biochemical analysis conveniently. On the experiment  so its application prospect is extensive.  the color image of urine test paper is taken by popular color digital camera and saved in the computer which installs a simple color space conversion (RGB &rarr XYZ &rarr L*a*b*) and the calculation software. Test sample is graded according to intelligent detection of quantitative color. The images taken every time were saved in computer  and the whole illness process will be monitored. This method can also use in other medicine biochemical analyses that have relation with color. Experiment result shows that this test method is quick and accurate  
Spatial-temporal characteristics in landscape evolution of the Yellow River Delta during 1855-2000 and a way out for the Yellow River estuary SCI/SSCI论文  OAI收割
2006
作者:  
Huang C.
收藏  |  浏览/下载:19/0  |  提交时间:2012/06/08
Fabrication and electron emission of carbon microtubes (EI CONFERENCE) 会议论文  OAI收割
Technical Digest of the 18th International Vacuum Nanoelectronics Conference, IVNC 2005, July 10, 2005 - July 14, 2005, Oxford, United kingdom
作者:  
Liu L.;  Liu L.;  Wang W.;  Wang W.
收藏  |  浏览/下载:40/0  |  提交时间:2013/03/25
Carbon nanotubes have been attracting attention because of their unique physical properties and their application potential for field emission cathode. Carbon nanotubes possess the following properties favorable for field emission material  such as a high aspect ratio and sharp tip  high chemical stability  high mechanical strength  stable at high temperature. Some research works on carbon nanotubes field emitter and field emission display have been reported. Here  a kind of carbon microtubes and its field emission properties are introduced. They have some different properties with carbon nanotubes  and the density is lower than carbon nanotubes bundles. These carbon microtubes are directly synthesized by liquidoid epitaxy method on silicon substrates at low temperature. The field emission properties of carbon microtubes are reported too. Carbon microtubes film is synthesized in liquid by electrolysis. The graphite plate is as anode  and n-silicon substrate with resistivity of 4-8 cm is as cathode. The electrolysis current is about 5-8mA/cm2  and applied voltage is 800-1500V. Temperatures of the methanol base solution is maintained at 60C in process of deposition of carbon microtubes. Carbon microtubes film is observed by scanning electron microscopy(SEM)  as shown in fig.1(a  b). The wall's thickness of carbon microtube is about 60nm. The diameter of carbon microtube is about 0.8 m. Raman spectrum of carbon microtubes film shows the two peaks at 1342and 1560cm-1. The field emission properties of carbon microtubes are measured in high vacuum chamber(10-5Pa). The emission area of carbon microtubes is 0.5cm 0.5cm. The threshold of field emission of the carbon microtubes film is about 3.6V/ m. Field emission property of carbon microtubes film is shown in fig.2. Another  when the electric field between anode and cathode is 10V/ m  the electric field distribution on single carbon microtube is also given after calculation according to electric field theory. Fig 3 shows that electric field distribution vertical section on the of single carbon microtube top with 2 m of highness. These results may help us to understand field emission properties of carbon microtubes. According to research results  it is found that liquidoid synthesis is simple method to produce carbon microtubes cold cathode material  and the carbon microtubes have better field emission properties. 2005 IEEE.