中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
生物物理研究所 [1]
采集方式
OAI收割 [3]
内容类型
会议论文 [2]
期刊论文 [1]
发表日期
2012 [2]
2011 [1]
学科主题
Biochemica... [1]
筛选
浏览/检索结果:
共3条,第1-3条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
A composite hardness stamp in 184 PDMS for nanostructures transfer in high fidelity (EI CONFERENCE)
会议论文
OAI收割
2012 12th IEEE International Conference on Nanotechnology, NANO 2012, August 20, 2012 - August 23, 2012, Birmingham, United kingdom
作者:
Du J.
;
Shi L.
;
Li S.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
To improve the fidelity of nanostructures in transfer process
a composite stamp with reasonable hardness distribution in 184 PDMS used to nanoimprint was studied. The stamp is composed of a stiff 184 PDMS structured layer and a soft 184 PDMS supporter layer. We studied the relationship between the hardness of the 184 PDMS and the proportion of each component in 184 PDMS. The appropriate components proportions of prepolymer and curing agent corresponding to the different region of the composite stamp were presented. The fabrication method of the stamp is also presented. Corresponding experiments were carried out by using this stamp. Kinds of nanostructures were transferred in one inch diameter area with good fidelity. The feature sizes of the structures were less than 100 nm. 2012 IEEE.
Evaluation of BACTEC MGIT 960 system for the second-line drugs susceptibility testing of Mycobacterium tuberculosis in China
期刊论文
OAI收割
JOURNAL OF MICROBIOLOGICAL METHODS, 2012, 卷号: 91, 期号: 1, 页码: 212-214
Zhao, Lili
;
Xia, Qiang
;
Lin, Nan
;
Liu, Binbin
;
Zhao, Xiuqin
;
Liu, Zhiguang
;
Wan, Kanglin
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/12/24
BACTEC MGIT 960 system
The proportion method
L-J media
Drug susceptibility testing
The second-line drugs
Mycobacterium tuberculosis
Design of programmable near infrared cold light source (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electronics and Optoelectronics, ICEOE 2011, July 29, 2011 - July 31, 2011, Dalian, China
作者:
Fu Q.
;
Wang B.
;
Wang B.
;
Wang R.
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2013/03/25
In the near infrared spectroscopy
detector of Charge-coupled Device requires very high stability for light source. We design the cold light source in the measurement of near infrared spectroscopy. Cold light source consists of high-power op amp OPA549 high current constant current source and proportion integral differential (PID) control algorithm. As is shown in the experimental results
the method is better
the overshoot is very small
the stability is excellent in the process of soft-start. While light intensity was able to meet the requirements of near-infrared instruments to measure. 2011 IEEE.