中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共10条,第1-10条 帮助

条数/页: 排序方式:
Spatio-temporal Resolution Studies on a Synchronous Streak Tube 期刊论文  OAI收割
Guangzi Xuebao/Acta Photonica Sinica, 2021, 卷号: 50, 期号: 4
作者:  
Tian, Liping;  Shen, Lingbin;  Chen, Lin;  Li, Lili;  Chen, Ping
  |  收藏  |  浏览/下载:56/0  |  提交时间:2021/06/02
A relativistic time-delay model at the micrometer level for satellite laser ranging 期刊论文  OAI收割
ASTROPHYSICS AND SPACE SCIENCE, 2015, 卷号: 359, 期号: 2, 页码: 1
作者:  
Han, Wen-Biao;  Cheng, Ran;  Tao, Jin-He;  Tang, Zheng-Hong
收藏  |  浏览/下载:26/0  |  提交时间:2016/01/14
The gravitational time delay in the field of a slowly moving body with arbitrary multipoles 期刊论文  OAI收割
PHYSICS LETTERS A, 2015, 卷号: 379, 期号: 4, 页码: 233-236
作者:  
Soffel, Michael H.;  Han, Wen-Biao
收藏  |  浏览/下载:30/0  |  提交时间:2015/08/04
The research of the accurate measure of static transfer function for the TDI CCD camera (EI CONFERENCE) 会议论文  OAI收割
3rd International Photonics and OptoElectronics Meetings, POEM 2010, November 2, 2010 - November 5, 2010, Wuhan, China
Guo-Ning L.; Long-Xu J.; Jian-Yue R.; Wen-Hua W.; Shuang-Li H.
收藏  |  浏览/下载:24/0  |  提交时间:2013/03/25
In the test course of static transfer function of TDI CCD camera  because of the influence that gets environmental and artificial etc. factor  the value of static transfer function measured at any time is between unceasing fluctuation  so  make accuracy reduce. To solve this problem  a kind of accurate measurement technique of static transfer function is put forward. First  before carrying out the measure of static quiet of transfer function  the best test point of transfer function of the TDI CCD camera must be determined  it is parallel to guarantee the rectangle target surface of parallel optical pipe and camera focal plane maintenance parallel  and again guarantee target strip in rectangle target and TDI CCD in camera focal plane maintenance vertical. TDI CCD catches rectangle target image  per 1000 lines of target mark image as a measures sample of static transfer function  exclude because of atmosphere tremble twisted  vague rectangle target mark image  retain 500 distinct and steady target mark image as measure sample set. Then  calculate the static transfer function of each measure sample respectively  take the average of all static quiet transfer function in measure sample set as the static transfer function of camera. Finally  the measure of the static transfer function for TDI CCD camera makes error analysis. Experimental results indicate that the value of the static transfer function of TDI CCD camera measured with this kind of method is 0.2923  with before measurement technique comparison  the value of static transfer function has raised 0.02  makes the accuracy of the measure of static transfer function have gotten raising.  
Maximum Entropy Method for Analyses of Fluorescence Correlation Spectra of Oligonucleotide Intra-Chain Collision 期刊论文  OAI收割
ACTA PHYSICO-CHIMICA SINICA, 2010, 卷号: 26, 期号: 4, 页码: 1087-1092
作者:  
Yin Yan-Dong;  Zhou Xiao-Xue;  Zhao Xin-Sheng
  |  收藏  |  浏览/下载:12/0  |  提交时间:2019/04/09
Electro-optical imaging system identification using pseudo-random binary pattern (EI CONFERENCE) 会议论文  OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Le Y.; Jian W.; Jianzhong Z.; Qiang S.; Jianzhuo L.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
Modulation transfer function in seeker camera limits resulting from missile flutter caused by aerodynamic force (EI CONFERENCE) 会议论文  OAI收割
2010 2nd International Conference on Industrial Mechatronics and Automation, ICIMA 2010, May 30, 2010 - May 31, 2010, Wuhan, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:25/0  |  提交时间:2013/03/25
The imaging quality of seeker in flight mode has been evaluated through analyzing the effects of missile flutter on optical modulation transfer function (MTF) of the optical system. Firstly the data of transverse vibration has been processed to eliminate the trend term caused by the trajectory  then obtained the displacement with two times trapezoidal integration. For the side rotation  the high frequency noise interference in the data has been filtered by using five-point moving average method. Took this model as the quivering rule between the object and the image  and then analyzed the effects of the transverse vibration and the side rotation on imaging quality through MTF. By calculation  the r.m.s value of the image motion caused by missile transverse vibration is 0.026mm  and the side rotation angle is 0.0044 . Through the establishment of two modulation transfer functions (MTF) of image random vibration and linear vibration  the results show that the image quality had declined  and the effect of transverse vibration on image quality is obvious. Through improving the rigidity of the missile and selection of small focal length optical system and shorten the time of exposure can improve the imaging quality of the seeker. 2010 IEEE.  
Modulation transfer function measurement technique for image sensor arrays (EI CONFERENCE) 会议论文  OAI收割
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
作者:  
Jiang H.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
Research on automatic multispectral images synthesis of space camera (EI CONFERENCE) 会议论文  OAI收割
Optoelectronic Imaging and Multimedia Technology, October 18, 2010 - October 20, 2010, Beijing, China
作者:  
Liu J.-G.;  Wu X.-X.;  Kong D.-Z.;  Zhou H.-D.
收藏  |  浏览/下载:17/0  |  提交时间:2013/03/25
Multilinear CCD Sensor was often used on space cameras to obtain multispectral images with each line representing different band channels. However images of different band channels obtained at the same time didn't coincide as there were spaces between lines. Pixel numbers to be adjusted between images of different channels varied when the space camera worked by swaying forward and backward or adjusted row transfer period to compensate image movement. An automatic multispectral images synthesis algorithm of space camera was put forward on the basis of analysis of such phenomenon. In this algorithm a new evaluation function was used to determine pixel numbers to be adjusted and the image regions of each band channel to be clipped. In this way images of different band channels could be synthesized automatically to obtain an accurate colorful image. This algorithm can be used to dispose a large mount of images from space camera directly without any manual disposal so that efficiency could be improved remarkably. In validation experiments the automatic multispectral images synthesis algorithm was applied in synthesis of images obtained from outside scene experiment of a multispectral space camera. Result of validation experiments proved that the automatic multispectral images synthesis algorithm can realize accurate multispectral images synthesis of space camera and the efficiency can be improved markedly. 2010 SPIE.  
Real-time video compressing under DSP/BIOS (EI CONFERENCE) 会议论文  OAI收割
MIPPR 2009 - Medical Imaging, Parallel Processing of Images, and Optimization Techniques: 6th International Symposium on Multispectral Image Processing and Pattern Recognition, October 30, 2009 - November 1, 2009, Yichang, China
Chen Q.-P.; Li G.-J.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
This paper presents real-time MPEG-4 Simple Profile video compressing based on the DSP processor. The programming framework of video compressing is constructed using TMS320C6416 Microprocessor  the architecture level optimizations are used to improve software pipeline. The system used DSP/BIOS to realize multi-thread scheduling. The whole system realizes high speed transition of a great deal of data. Experimental results show the encoder can realize real-time encoding of 768*576  TDS510 simulator and PC. It uses embedded real-time operating system DSP/BIOS and the API functions to build periodic function  25 frame/s video images. 2009 Copyright SPIE - The International Society for Optical Engineering.  tasks and interruptions etcs. Realize real-time video compressing. To the questions of data transferring among the system. Based on the architecture of the C64x DSP  utilized double buffer switched and EDMA data transfer controller to transit data from external memory to internal  and realize data transition and processing at the same time