中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [6]
地理科学与资源研究所 [1]
数学与系统科学研究院 [1]
自动化研究所 [1]
采集方式
OAI收割 [9]
内容类型
会议论文 [6]
SCI/SSCI论文 [1]
学位论文 [1]
期刊论文 [1]
发表日期
2013 [1]
2012 [1]
2011 [3]
2009 [1]
2008 [1]
2005 [1]
更多
学科主题
筛选
浏览/检索结果:
共9条,第1-9条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Error analysis of the micro temperature control system (EI CONFERENCE)
会议论文
OAI收割
2012 International Conference on Measurement, Instrumentation and Automation, ICMIA 2012, September 15, 2012 - September 16, 2012, Guangzhou, China
Han Z.
;
Song K.
收藏
  |  
浏览/下载:48/0
  |  
提交时间:2013/03/25
In order to improve the measurement accuracy of optical detection instruments
temperature control circuits for narrow band-pass filters are given
and the error analysis is applied to temperature control circuits.The principle of a temperature measurement circuit is studied and the method of a driver circuit is described. A variety of influencing factors of temperature control accuracy are discussed. Moreover
for these error factors
improvement measures are given to reduce the nonlinear error. Finally
circuit parameter error is quantified to propose a calculation method for margin of error in a temperature control system. (2013) Trans Tech Publications
Switzerland.
Assessing the quality of training data in the supervised classification of remotely sensed imagery: a correlation analysis
SCI/SSCI论文
OAI收割
2012
作者:
Ge Y.
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2014/12/25
quality assessment of training data
rough set
measures
correlation
analysis
accuracy assessment
land-cover
scale
map
Laser pulse coded signal frequency measuring device based on DSP and CPLD (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Laser Sensing and Imaging; and Biological and Medical Applications of Photonics Sensing and Imaging, May 24, 2011 - May 26, 2011, Beijing, China
作者:
Zhang H.-B.
;
Wang T.-F.
;
Guo R.-H.
;
Li Y.
;
Li Y.
收藏
  |  
浏览/下载:37/0
  |  
提交时间:2013/03/25
Laser pulse code is an anti-jamming measures used in semi-active laser guided weapons. On account of the laser-guided signals adopting pulse coding mode and the weak signal processing
it need complex calculations in the frequency measurement process according to the laser pulse code signal time correlation to meet the request in optoelectronic countermeasures in semi-active laser guided weapons. To ensure accurately completing frequency measurement in a short time
it needed to carry out self-related process with the pulse arrival time series composed of pulse arrival time
calculate the signal repetition period
and then identify the letter type to achieve signal decoding from determining the time value
number and rank number in a signal cycle by Using CPLD and DSP for signal processing chip
designing a laser-guided signal frequency measurement in the pulse frequency measurement device
improving the signal processing capability through the appropriate software algorithms. In this article
we introduced the principle of frequency measurement of the device
described the hardware components of the device
the system works and software
analyzed the impact of some system factors on the accuracy of the measurement. The experimental results indicated that this system improve the accuracy of the measurement under the premise of volume
real-time
anti-interference
low power of the laser pulse frequency measuring device. The practicality of the design
reliability has been demonstrated from the experimental point of view.
Design and calibration of the solar irradiance monitor (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:
Yang D.-J.
;
Gong C.-H.
;
Wang Y.-P.
;
Ye X.
;
Fang W.
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2013/03/25
The solar irradiance monitor (SIM)
with the design accuracy of 5
used to monitor the secular changes of the total solar irradiance on FY-3 satellite
takes the sun-scanning measurement method on-orbit. Compared to the sun-tracking measurement method
this method simplifies the structure and cuts the cost
but the measuring accuracy is affected by the sun-synchronous orbit
sunlight incidence angle and the installing angle of the SIM in the satellite. Through the ground calibration experiment
studies on the affection of different sunlight incidence angles to the measurement accuracy. First
by the satellite tool kit (STK) simulation software
simulates the orbital parameters of the sun-synchronous satellite
and calculates the Sun ascension and declination at any time. By the orbit coordinate transformation matrix gets the components of the Sun vectors to the axes of the satellite
and base on the components designs the field of view and the installing angles of the SIM. Then
designs and completes the calibration experiment to calibrate the affection of the incidence angles. Selecting 11 different angles between the sunlight and the satellite X-axis
measures the total solar irradiance by the SIM at each angle
and compares to the irradiances of the SIAR reference radiometers
and gets the coefficient curves of the three channels of the SIM. Finally
by the quadratic fitting
gets the correction equations on the incidence angles: R 1=5.7110-52 -2.45310 -3+1.0302
R2=2.8410-5-1. 96510-3+1.0314 and R3 =1.7210 -52-4.18410-4+0.9946. The equations will aimprove the on-orbit measurement accuracy of the solar irradiance
and are very important to the on-orbit data processing after the satellite launched. 2011 SPIE.
The research of the accurate measure of static transfer function for the TDI CCD camera (EI CONFERENCE)
会议论文
OAI收割
3rd International Photonics and OptoElectronics Meetings, POEM 2010, November 2, 2010 - November 5, 2010, Wuhan, China
Guo-Ning L.
;
Long-Xu J.
;
Jian-Yue R.
;
Wen-Hua W.
;
Shuang-Li H.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
In the test course of static transfer function of TDI CCD camera
because of the influence that gets environmental and artificial etc. factor
the value of static transfer function measured at any time is between unceasing fluctuation
so
make accuracy reduce. To solve this problem
a kind of accurate measurement technique of static transfer function is put forward. First
before carrying out the measure of static quiet of transfer function
the best test point of transfer function of the TDI CCD camera must be determined
it is parallel to guarantee the rectangle target surface of parallel optical pipe and camera focal plane maintenance parallel
and again guarantee target strip in rectangle target and TDI CCD in camera focal plane maintenance vertical. TDI CCD catches rectangle target image
per 1000 lines of target mark image as a measures sample of static transfer function
exclude because of atmosphere tremble twisted
vague rectangle target mark image
retain 500 distinct and steady target mark image as measure sample set. Then
calculate the static transfer function of each measure sample respectively
take the average of all static quiet transfer function in measure sample set as the static transfer function of camera. Finally
the measure of the static transfer function for TDI CCD camera makes error analysis. Experimental results indicate that the value of the static transfer function of TDI CCD camera measured with this kind of method is 0.2923
with before measurement technique comparison
the value of static transfer function has raised 0.02
makes the accuracy of the measure of static transfer function have gotten raising.
Angular rate of test table based on high-speed non-contact measurement (EI CONFERENCE)
会议论文
OAI收割
9th International Conference on Electronic Measurement and Instruments, ICEMI 2009, August 16, 2009 - August 19, 2009, Beijing, China
作者:
Yang L.
;
Zhao Y.
;
Zhao Y.
;
Zhao Y.
;
Yang L.
收藏
  |  
浏览/下载:137/0
  |  
提交时间:2013/03/25
This article will introduces a high-speed non-contact method that can measures the angular rate of a test table though an objective perspective. This method adopts a collimator tube that can be measured as a target fixed to the test table
and the target corresponds to the angular position of the test table. In the process of the table rotating
the camera will to keep track of the objective at a high speed. Due to the high sampling frequency of the high-speed camera
instantaneous angular rate of test table can be measured. With pixel subdivision technology
its measuring accuracy can be up to 0.02 pixels. We use this methods measured a low-speed test table's angular rate and analyzed the data. The error analysis shows when the rate of the test table is 0.20/s
the accuracy of the method can achieve 0.0220%. 2009 IEEE.
Autofocusing technique based on image processing for remote-sensing camera (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2007 - Image Processing, September 9, 2007 - September 12, 2007, Beijing, China
作者:
Wang X.
;
Xu S.-Y.
;
Wang X.
;
Wang X.
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2013/03/25
The key to the auto-focusing technique based on image processing is the selection of focus measure reflecting image definition. Usually the measures derived are on the premise of the images acquired with the same scene. As for the remote-sensing camera working in linear CCD push-broom imaging mode
the premise doesn't exist because the scenes shot are different at any moment
which brings about difficulties to the selection of the focus measure. To evaluate the image definition
the focus measure based on blur estimation for rough adjustment is proposed to estimate the focused position by only two different lens positions
which greatly saves the auto-focusing time. Another evaluation function based on edge sharpness is developed to find best imaging position in the narrow range. Simulations show that the combination of the two measures has the advantages of rapid reaction and high accuracy.
Test data sets and evaluation of gene prediction programs on the rice genome
期刊论文
OAI收割
JOURNAL OF COMPUTER SCIENCE AND TECHNOLOGY, 2005, 卷号: 20, 期号: 4, 页码: 446-453
作者:
Li, H
;
Liu, JS
;
Xu, Z
;
Jin, J
;
Fang, L
  |  
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2018/07/30
gene prediction
rice genome
test sets
accuracy measures
hidden Markov models
dynamic programming
视频镜头自动检测的研究
学位论文
OAI收割
工学硕士, 中国科学院自动化研究所: 中国科学院自动化研究所, 2001
李大龙
收藏
  |  
浏览/下载:52/0
  |  
提交时间:2015/09/02
镜头检测
比值直方图
光照不变测度
速度和精度
Shot detection
Ratio Histogram
Illumination Invariant Measures
Speed and Accuracy