中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共9条,第1-9条 帮助

条数/页: 排序方式:
Error analysis of the micro temperature control system (EI CONFERENCE) 会议论文  OAI收割
2012 International Conference on Measurement, Instrumentation and Automation, ICMIA 2012, September 15, 2012 - September 16, 2012, Guangzhou, China
Han Z.; Song K.
收藏  |  浏览/下载:48/0  |  提交时间:2013/03/25
Assessing the quality of training data in the supervised classification of remotely sensed imagery: a correlation analysis SCI/SSCI论文  OAI收割
2012
作者:  
Ge Y.
收藏  |  浏览/下载:31/0  |  提交时间:2014/12/25
Laser pulse coded signal frequency measuring device based on DSP and CPLD (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Laser Sensing and Imaging; and Biological and Medical Applications of Photonics Sensing and Imaging, May 24, 2011 - May 26, 2011, Beijing, China
作者:  
Zhang H.-B.;  Wang T.-F.;  Guo R.-H.;  Li Y.;  Li Y.
收藏  |  浏览/下载:37/0  |  提交时间:2013/03/25
Laser pulse code is an anti-jamming measures used in semi-active laser guided weapons. On account of the laser-guided signals adopting pulse coding mode and the weak signal processing  it need complex calculations in the frequency measurement process according to the laser pulse code signal time correlation to meet the request in optoelectronic countermeasures in semi-active laser guided weapons. To ensure accurately completing frequency measurement in a short time  it needed to carry out self-related process with the pulse arrival time series composed of pulse arrival time  calculate the signal repetition period  and then identify the letter type to achieve signal decoding from determining the time value  number and rank number in a signal cycle by Using CPLD and DSP for signal processing chip  designing a laser-guided signal frequency measurement in the pulse frequency measurement device  improving the signal processing capability through the appropriate software algorithms. In this article  we introduced the principle of frequency measurement of the device  described the hardware components of the device  the system works and software  analyzed the impact of some system factors on the accuracy of the measurement. The experimental results indicated that this system improve the accuracy of the measurement under the premise of volume  real-time  anti-interference  low power of the laser pulse frequency measuring device. The practicality of the design  reliability has been demonstrated from the experimental point of view.  
Design and calibration of the solar irradiance monitor (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:  
Yang D.-J.;  Gong C.-H.;  Wang Y.-P.;  Ye X.;  Fang W.
收藏  |  浏览/下载:27/0  |  提交时间:2013/03/25
The solar irradiance monitor (SIM)  with the design accuracy of 5  used to monitor the secular changes of the total solar irradiance on FY-3 satellite  takes the sun-scanning measurement method on-orbit. Compared to the sun-tracking measurement method  this method simplifies the structure and cuts the cost  but the measuring accuracy is affected by the sun-synchronous orbit  sunlight incidence angle and the installing angle of the SIM in the satellite. Through the ground calibration experiment  studies on the affection of different sunlight incidence angles to the measurement accuracy. First  by the satellite tool kit (STK) simulation software  simulates the orbital parameters of the sun-synchronous satellite  and calculates the Sun ascension and declination at any time. By the orbit coordinate transformation matrix gets the components of the Sun vectors to the axes of the satellite  and base on the components designs the field of view and the installing angles of the SIM. Then  designs and completes the calibration experiment to calibrate the affection of the incidence angles. Selecting 11 different angles between the sunlight and the satellite X-axis  measures the total solar irradiance by the SIM at each angle  and compares to the irradiances of the SIAR reference radiometers  and gets the coefficient curves of the three channels of the SIM. Finally  by the quadratic fitting  gets the correction equations on the incidence angles: R 1=5.7110-52 -2.45310 -3+1.0302  R2=2.8410-5-1. 96510-3+1.0314 and R3 =1.7210 -52-4.18410-4+0.9946. The equations will aimprove the on-orbit measurement accuracy of the solar irradiance  and are very important to the on-orbit data processing after the satellite launched. 2011 SPIE.  
The research of the accurate measure of static transfer function for the TDI CCD camera (EI CONFERENCE) 会议论文  OAI收割
3rd International Photonics and OptoElectronics Meetings, POEM 2010, November 2, 2010 - November 5, 2010, Wuhan, China
Guo-Ning L.; Long-Xu J.; Jian-Yue R.; Wen-Hua W.; Shuang-Li H.
收藏  |  浏览/下载:25/0  |  提交时间:2013/03/25
In the test course of static transfer function of TDI CCD camera  because of the influence that gets environmental and artificial etc. factor  the value of static transfer function measured at any time is between unceasing fluctuation  so  make accuracy reduce. To solve this problem  a kind of accurate measurement technique of static transfer function is put forward. First  before carrying out the measure of static quiet of transfer function  the best test point of transfer function of the TDI CCD camera must be determined  it is parallel to guarantee the rectangle target surface of parallel optical pipe and camera focal plane maintenance parallel  and again guarantee target strip in rectangle target and TDI CCD in camera focal plane maintenance vertical. TDI CCD catches rectangle target image  per 1000 lines of target mark image as a measures sample of static transfer function  exclude because of atmosphere tremble twisted  vague rectangle target mark image  retain 500 distinct and steady target mark image as measure sample set. Then  calculate the static transfer function of each measure sample respectively  take the average of all static quiet transfer function in measure sample set as the static transfer function of camera. Finally  the measure of the static transfer function for TDI CCD camera makes error analysis. Experimental results indicate that the value of the static transfer function of TDI CCD camera measured with this kind of method is 0.2923  with before measurement technique comparison  the value of static transfer function has raised 0.02  makes the accuracy of the measure of static transfer function have gotten raising.  
Angular rate of test table based on high-speed non-contact measurement (EI CONFERENCE) 会议论文  OAI收割
9th International Conference on Electronic Measurement and Instruments, ICEMI 2009, August 16, 2009 - August 19, 2009, Beijing, China
作者:  
Yang L.;  Zhao Y.;  Zhao Y.;  Zhao Y.;  Yang L.
收藏  |  浏览/下载:137/0  |  提交时间:2013/03/25
This article will introduces a high-speed non-contact method that can measures the angular rate of a test table though an objective perspective. This method adopts a collimator tube that can be measured as a target fixed to the test table  and the target corresponds to the angular position of the test table. In the process of the table rotating  the camera will to keep track of the objective at a high speed. Due to the high sampling frequency of the high-speed camera  instantaneous angular rate of test table can be measured. With pixel subdivision technology  its measuring accuracy can be up to 0.02 pixels. We use this methods measured a low-speed test table's angular rate and analyzed the data. The error analysis shows when the rate of the test table is 0.20/s  the accuracy of the method can achieve 0.0220%. 2009 IEEE.  
Autofocusing technique based on image processing for remote-sensing camera (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2007 - Image Processing, September 9, 2007 - September 12, 2007, Beijing, China
作者:  
Wang X.;  Xu S.-Y.;  Wang X.;  Wang X.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
The key to the auto-focusing technique based on image processing is the selection of focus measure reflecting image definition. Usually the measures derived are on the premise of the images acquired with the same scene. As for the remote-sensing camera working in linear CCD push-broom imaging mode  the premise doesn't exist because the scenes shot are different at any moment  which brings about difficulties to the selection of the focus measure. To evaluate the image definition  the focus measure based on blur estimation for rough adjustment is proposed to estimate the focused position by only two different lens positions  which greatly saves the auto-focusing time. Another evaluation function based on edge sharpness is developed to find best imaging position in the narrow range. Simulations show that the combination of the two measures has the advantages of rapid reaction and high accuracy.  
Test data sets and evaluation of gene prediction programs on the rice genome 期刊论文  OAI收割
JOURNAL OF COMPUTER SCIENCE AND TECHNOLOGY, 2005, 卷号: 20, 期号: 4, 页码: 446-453
作者:  
Li, H;  Liu, JS;  Xu, Z;  Jin, J;  Fang, L
  |  收藏  |  浏览/下载:22/0  |  提交时间:2018/07/30
视频镜头自动检测的研究 学位论文  OAI收割
工学硕士, 中国科学院自动化研究所: 中国科学院自动化研究所, 2001
李大龙
收藏  |  浏览/下载:52/0  |  提交时间:2015/09/02