中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [1]
采集方式
OAI收割 [1]
内容类型
会议论文 [1]
发表日期
2008 [1]
学科主题
筛选
浏览/检索结果:
共1条,第1-1条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
UV-VUV spectral irradiance responsivity calibration for space remote sensing spectroradiometer (EI CONFERENCE)
会议论文
OAI收割
Advanced Materials and Devices for Sensing and Imaging III, November 12, 2007 - November 14, 2007, Beijing, China
作者:
Yu H.
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/03/25
In order to overcome the irradiance responsivity calibration troubles caused by the weak response of most spectral radiometers in ultraviolet band and poor ratio of signal to noise
and to meet special calibration condition for some remote sensing spectroradiometers in space
a spectral irradiance responsivity calibration unit based on parallel light illumination mode is established
it is composed of a 150W deuterium lamp and a spherical mirror. The calibration unit gets the output standard value of spectral irradiance by irradiance transfer
this way avoids the spectral reflectance measurement difficulty of the spherical mirror. A flight spectral radiometer model used for space remote sense was calibrated in range from 160nm to 300nm
the calibration error of spectral irradiance responsivity is 4.7%. Some factors which contribute to calibration uncertainties are discussed.