A modified rock mass classification considering seismic effects in the basic quality (BQ) system
期刊论文
OAI收割
BULLETIN OF ENGINEERING GEOLOGY AND THE ENVIRONMENT, 2021, 页码: 12
作者:
Cui, Zhen
;
Sheng, Qian
;
Zhang, Gui-min
;
Liu, Hua
  |  
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2021/05/25
Rock mass classification
Tunnel
Rock mass basic quality
Seismic design
Intactness index of rock mass
A-BQ, a classification system for anisotropic rock mass based on China National Standard
期刊论文
OAI收割
JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2020, 卷号: 27, 期号: 10, 页码: 3090-3102
作者:
Guo, Song-feng
;
Qi, Sheng-wen
;
Saroglou, Charalampos
  |  
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2021/01/08
anisotropy
rock mass
basic quality
classification
tunnel
slope
Design of the real-time autofocusing system for collimator with long focus length and large aperture (EI CONFERENCE)
会议论文
OAI收割
2011 International Academic Conference on Numbers, Intelligence, Manufacturing Technology and Machinery Automation, MAMT 2011, December 24, 2011 - December 25, 2011, Wuhan, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:45/0
  |  
提交时间:2013/03/25
Large aperture collimator which has been widely used for calibrating and testing various optical devices plays an essential role in correlative laboratories. As being the basic testing and calibration equipment
the large aperture collimator's accuracy should be much higher than the device under testing in order to ensure the accuracy of the measurement. However
the process of adjusting the collimator is extremely complicated due to the collimator's large aperture and long focal length. So it is difficult to ensure the measurement's quality and easy to cause the system being vulnerable to the surrounding environment. One of the most common problems is defocus. In order to solve the problem above
this issue presents a new type of autocollimator autofocusing system which uses pentaprism instead of using large-aperture plane mirror
semiconductor lasers as light source and CCD sensor as receiver. The system is smaller
lighter
and more convenient when using. The computer simulation shows that the autofocusing system's resolution could reach the accuracy of 40m. If we use the relevant algorithms to execute the sub-pixel scanning
the resolution could reach the accuracy of 10m. It shows that the system could satisfy the required testing precision of testing large aperture optical device.
Animated models coarsening with local area distortion and deformation degree control (EI CONFERENCE)
会议论文
OAI收割
International Conference on Image Processing and Pattern Recognition in Industrial Engineering, August 7, 2010 - August 8, 2010, Xi'an, China
作者:
Zhang S.
;
Zhao J.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
In computer graphics applications
mesh coarsening is an important technique to alleviate the workload of visualization processing. Compared to the extensive works on static model approximation
very little attentions have been paid to animated models. In this paper
we propose a new method to approximate animated models with local area distortion and deformation degree control. Our method uses an improved quadric error metric guided by a local area distortion measurement as a basic hierarchy. Also
we define a deformation degree parameter to be embedded into the aggregated quadric errors
so areas with large deformation during the animation can be successfully preserved. Finally
a mesh optimization process is proposed to further reduce the geometric distortion for each frame. Our approach is fast
easy to implement
and as a result good quality dynamic approximations with well-preserved sharp features can be generated at any given frame. 2010 SPIE.
An improved method for generating multiresolution animation models (EI CONFERENCE)
会议论文
OAI收割
2009 11th IEEE International Conference on Computer-Aided Design and Computer Graphics, CAD/Graphics 2009, August 19, 2009 - August 21, 2009, Huangshan, China
作者:
Zhang S.
收藏
  |  
浏览/下载:37/0
  |  
提交时间:2013/03/25
In computer graphics
animated models are widely used to represent time-varying data. In this paper
we propose an improved method to generate multiresolution animation models. We use a curvature sensitive quadric error metric (QEM) criterion as our basic measurement
which can preserve local features on the surface. We append a deformation weight to the aggregated edge contraction cost for the whole animation to preserve areas with large deformation. At last
we introduce a mesh optimization method to deal with the animation sequence
which can efficiently improve the temporal coherence and reduce visual artifacts. The results show our approach is efficient
easy to implement
and good quality progressive animation models can be generated at any level of detail. 2009 IEEE.
Analysis and design of No-Reference Image Quality Assessment (EI CONFERENCE)
会议论文
OAI收割
2008 International Conference on MultiMedia and Information Technology, MMIT 2008, December 30, 2008 - December 31, 2008, Three Gorges, China
作者:
Wang L.
;
Wang L.
;
Wang L.
收藏
  |  
浏览/下载:16/0
  |  
提交时间:2013/03/25
No-Reference (NR) Image Quality Assessment (IQA) seeks to assign quality scores that are consistent with human perception but without an explicit comparison with the reference image. Unfortunately
the field of NR IQA has been largely unexplored. The basic problems in NR IQA are discussed in this paper. and several methods used in NR IQA are explained and analyzed. Finally
an overall NR IQA method is designed. It should be a synthetical index
which applying fuzzy measures and fuzzy integrals
incorporating Human Vision System (HVS) characteristics and adhering to the philosophy of quantifying quality through blind distortion measurement. 2008 IEEE.