中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
国家空间科学中心 [2]
长春光学精密机械与物... [2]
国家授时中心 [1]
采集方式
OAI收割 [5]
内容类型
会议论文 [4]
期刊论文 [1]
发表日期
2020 [1]
2017 [1]
2016 [1]
2011 [1]
2007 [1]
学科主题
筛选
浏览/检索结果:
共5条,第1-5条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Real-time detection of BDS orbit manoeuvres based on the combination of GPS and BDS observations
期刊论文
OAI收割
IET RADAR SONAR AND NAVIGATION, 2020, 卷号: 14, 期号: 10, 页码: 1603-1609
作者:
Tu, Rui
;
Zhang, Rui
;
Liu, Zhanke
;
Fan, Lihong
;
Han, Junqiang
  |  
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2021/11/29
Global Positioning System
artificial satellites
object detection
BDS orbit manoeuvre detection method
Global Positioning System
single BDS system
orbital manoeuvre
observation time
real-time detection
Chinese BeiDou navigation satellite system
timing services
BDS satellites
continuous PNT services
reliable PNT services
geostationary orbit
global positioning
navigation
and timing services
inclined geosynchronous
medium earth orbit
MEO
combined GPS-BDS system
receiver clock error bias
time 157
0 min
WIND SPEED RETRIEVING FOR COMBINED OBSERVATIONS OF SCATTEROMETER AND RADIOMETER ONBOARD HY-2A FOR TYPHOONS USING NEURAL NETWORK
会议论文
OAI收割
Fort Worth, TX, JUL 23-28, 2017
作者:
Xu, Xingou
;
Dong, Xiaolong
;
Zhang, Lei
;
Zhu, Di
;
Lang, Shuyan
  |  
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2018/05/04
Typhoon
Wind Speed Retrieving
Scatterometer
Radiometer
Combined Observation
Hy-2a
WIND FIELD RETRIEVING UNDER RAINY CONDITION FROM COMBINED OBSERVATIONS OF SCATTEROMETER AND RADIOMETER ONBOARD HY-2A
会议论文
OAI收割
36th IEEE International Geoscience and Remote Sensing Symposium (IGARSS), Beijing, PEOPLES R CHINA, JUL 10-15, 2016
作者:
Xu, Xingou
;
Dong, Xiaolong
;
Zhu, Di
;
Lang, Shuyan
;
Chen, Kuntang
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2017/04/07
Rainy condition
wind field retrieving
scatterometer
radiometer
combined observation
HY-2A
The sequence measurement system of the IR camera (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:
Zhang H.-B.
;
Han H.-X.
;
Geng A.-H.
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2013/03/25
Currently
the IR cameras are broadly used in the optic-electronic tracking
optic-electronic measuring
fire control and optic-electronic countermeasure field
but the output sequence of the most presently applied IR cameras in the project is complex and the giving sequence documents from the leave factory are not detailed. Aiming at the requirement that the continuous image transmission and image procession system need the detailed sequence of the IR cameras
the sequence measurement system of the IR camera is designed
and the detailed sequence measurement way of the applied IR camera is carried out. The FPGA programming combined with the SignalTap online observation way has been applied in the sequence measurement system
and the precise sequence of the IR camera's output signal has been achieved
the detailed document of the IR camera has been supplied to the continuous image transmission system
image processing system and etc. The sequence measurement system of the IR camera includes CameraLink input interface part
LVDS input interface part
FPGA part
CameraLink output interface part and etc
thereinto the FPGA part is the key composed part in the sequence measurement system. Both the video signal of the CmaeraLink style and the video signal of LVDS style can be accepted by the sequence measurement system
and because the image processing card and image memory card always use the CameraLink interface as its input interface style
the output signal style of the sequence measurement system has been designed into CameraLink interface. The sequence measurement system does the IR camera's sequence measurement work and meanwhile does the interface transmission work to some cameras. Inside the FPGA of the sequence measurement system
the sequence measurement program
the pixel clock modification
the SignalTap file configuration and the SignalTap online observation has been integrated to realize the precise measurement to the IR camera. Te sequence measurement program written by the verilog language combining the SignalTap tool on line observation can count the line numbers in one frame
pixel numbers in one line and meanwhile account the line offset and row offset of the image. Aiming at the complex sequence of the IR camera's output signal
the sequence measurement system of the IR camera accurately measures the sequence of the project applied camera
supplies the detailed sequence document to the continuous system such as image processing system and image transmission system and gives out the concrete parameters of the fval
lval
pixclk
line offset and row offset. The experiment shows that the sequence measurement system of the IR camera can get the precise sequence measurement result and works stably
laying foundation for the continuous system. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
The synthesis and field emission property of carbon nanotubes on carbon fibers substrate (EI CONFERENCE)
会议论文
OAI收割
Technical Digest of the 20th International Vacuum Nanoelectronics Conference, IVNC 07, July 8, 2008 - July 12, 2008, Chicago, IL, United states
Leyong Z.
;
Weibiao W.
;
Jingqiu L.
;
Yuxue X.
;
Da L.
;
Song C.
;
Haifeng Z.
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2013/03/25
Using ferrocene as catalyst precursor
C2H2 as carbon source
carbon nanotubes (CNTs) with uniform density were synthesized on carbon fibers substrate by floating catalyst method. The morphology and microstructure were characterized by field emission scanning electron microscope (FESEM) and high-resolution transmission electron microscopy (HRTEM). The observation showed that the length of CNTs is about 2 m
the average space between adjacent CNTs is about 300 nm and the diameter of CNT is about 45 nm. The less dense "short and stubby" aligned CNTs films should have good electron field emission characteristics. The results of field emission showed that the emission current of CNTs/carbon fibers was 5 A at the field of 2.5 V/m
and the emission current can be 280 A with a field of 7 V/m (the specimen area is 0.25 cm2 and the distance between cathode and anode is 200 m). The calculation based on the F-N plot indicated that the field enhancement factor of CNTs tip is 499122. Using the conductivity and chemical stability of carbon fibers and the uniform and sparse density distribution of CNTs on carbon fibers substrate
the tip predominance of carbon nanotubes can be exerted
and simultaneously the effect of screening effects between adjacent carbon nanotubes on the field emission performance can also be effectively decreased. The CNTs synthesized on carbon fibers substrate has many predominances for the fabrication of cold cathode devices. For example
using the removability of carbon fibers
the cathode of CNTs/carbon fibers can be arbitrarily moved
enlaced or combined to form different patterns
and the cathode of CNTs/carbon fibers can be also fabricated in large size. Therefore
CNTs/carbon fibers may have potential application in field emission displays.