中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共3条,第1-3条 帮助

条数/页: 排序方式:
Design of visible light / LWIR dual-band common aperture imaging optical system 会议论文  OAI收割
Beijing, China, 2019-07-07
作者:  
Ma, Zhanpeng;  Wang, Hu;  Shen, Yang;  Wang, Fang;  Xue, Yaoke
  |  收藏  |  浏览/下载:51/0  |  提交时间:2020/03/04
Design of the real-time autofocusing system for collimator with long focus length and large aperture (EI CONFERENCE) 会议论文  OAI收割
2011 International Academic Conference on Numbers, Intelligence, Manufacturing Technology and Machinery Automation, MAMT 2011, December 24, 2011 - December 25, 2011, Wuhan, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:42/0  |  提交时间:2013/03/25
Large aperture collimator which has been widely used for calibrating and testing various optical devices plays an essential role in correlative laboratories. As being the basic testing and calibration equipment  the large aperture collimator's accuracy should be much higher than the device under testing in order to ensure the accuracy of the measurement. However  the process of adjusting the collimator is extremely complicated due to the collimator's large aperture and long focal length. So it is difficult to ensure the measurement's quality and easy to cause the system being vulnerable to the surrounding environment. One of the most common problems is defocus. In order to solve the problem above  this issue presents a new type of autocollimator autofocusing system which uses pentaprism instead of using large-aperture plane mirror  semiconductor lasers as light source and CCD sensor as receiver. The system is smaller  lighter  and more convenient when using. The computer simulation shows that the autofocusing system's resolution could reach the accuracy of 40m. If we use the relevant algorithms to execute the sub-pixel scanning  the resolution could reach the accuracy of 10m. It shows that the system could satisfy the required testing precision of testing large aperture optical device.  
A new method of image reconstruction with high resolution in X-ray coded aperture imaging (EI CONFERENCE) 会议论文  OAI收割
Laser-Generated, Synchrotron, and Other Laboratory X-Ray and EUV Sources, Optics, and Applications II, August 2, 2005 - August 4, 2005, San Diego, CA, United states
作者:  
Sun Y.;  Sun Y.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
In the processing diagnosis of the inertia confinement fusion (ICF)  the ring coded aperture imaging technique is applied in order to gain high space and time resolutions simultaneously. The key of acquiring high spatial resolution is how to obtain a point spread function of an imaging system. The common method is the firsthand projection method which is an approximate one. The x-ray diffraction effect is neglected in the method  so the resolution of reconstructed image is decreased. We have derived the point spread function (PSF) of the ring coded aperture from scalar diffraction theory. And the Wiener filter is fabricated on the basis of the PSF. In National Key Laboratory of Laser Fusion  at China Academy of Engineering Physics  the imaging experiment on the diagnosis of ICF is completed using the ring coded aperture plate with inner diameter d1 = 250m and outer diameter d2 = 260m . The obtained coded image is processed by the Wiener filter which diffractive effect is considered. The processed results have shown that resolution and modulation contrast of acquired image are evidently better than the results obtained by the firsthand projection method.