中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
力学研究所 [1]
采集方式
OAI收割 [3]
内容类型
会议论文 [2]
期刊论文 [1]
发表日期
2024 [1]
2013 [1]
2011 [1]
学科主题
筛选
浏览/检索结果:
共3条,第1-3条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
A stochastic multi-scale thermal conductivity numerical model for 2D C/SiC-Ti
3
SiC
2
composite
期刊论文
OAI收割
MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2024, 页码: 17
作者:
Ma T(马特)
;
Wang RX(王睿星)
;
Yuan W(袁武)
;
Jia, Xiaodong
;
Song HW(宋宏伟)
  |  
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2024/08/12
2D C/SiC-Ti3SiC2 composite
stochastic multi-scale model
thermal conductivity
temperature field
laser irradiation experiment
Laser cleaning of neutral attenuator plate based on low power laser diode (EI CONFERENCE)
会议论文
OAI收割
2nd International Conference on Energy, Environment and Sustainable Development, EESD 2012, October 12, 2012 - October 14, 2012, Jilin, China
作者:
Chen Y.
;
Li L.
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2013/03/25
Laser cleaning is a non-contact
green and environmental cleaning method
which can effectively remove particulate contaminations of sizes as small as 0.1 m without damage to the optics. But most laser cleaning devices are large and heavy
also expensive due to using large lasers such as CO2 laser
YAG Laser etc. In this work a low power LD was tried to clean fingerprint and dust contaminated on the surface of the attenuator glasses plates. In the laser cleaning experiment with low power diode the fingerprint grease can be efficient to be cleaned
but there is no evident effect for cleaning inorganic dust. The cleaning different degree of fingerprint contaminations was investigated at the variable laser parameters
including laser power and irradiation time. An optical microscope was used to analyze the cleaning effect. The results show that low power LD can effectively remove the fingerprint on the surface of absorptive-type attenuator glass plates. On the premise that the attenuator optics glasses are not damaged
the cleaning area increases with the increase of radiation time and laser power. The cleaning area doesn't change much with the variation of laser frequency when the other parameters are the same. (2013) Trans Tech Publications
Switzerland.
Experiment analysis of CO2 laser disturbance on long-wave infrared HgCdTe detector (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electric Information and Control Engineering, ICEICE 2011, April 15, 2011 - April 17, 2011, Wuhan, China
作者:
Wang S.-W.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
Theoretical analysis and experimental study were carried out on the high-power CO2 laser disturbance to long-wave infrared (LWIR) HgCdTe detector in this paper. Based on the practical parameters of experiment
the theoretical model of temperature-rise is adopted to calculate the variation of the temperature with the time and the power of laser for laser irradiation on the detector. After that
the damage threshold is 110W/cm2. This experimental phenomenon well agrees with the results predicted by the theoretical calculation. The conclusions have a certain reference value for the laser defense of detector. 2011 IEEE.
the high-power laser damage mechanism to LWIR detector is discussed
and compares with the experimental results of laser irradiation the detector on the distance of 15km. The theoretical and experimental results demonstrate that the interference threshold of the detector is 20.5W/cm 2