中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共5条,第1-5条 帮助

条数/页: 排序方式:
Design of driving circuit for binocular CCD image system (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optoelectronic Materials and Devices for Detector, Imager, Display, and Energy Conversion Technology, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:45/0  |  提交时间:2013/03/25
The paper designs a driving circuit of high sensitive  wide dynamic and high signal-to-noise ratio for binocular CCD imaging system which adopts a Dalsa-made high resolution full-frame 33-mega pixels area CCD FTF5066M. Inner structure and driving timing of the FTF5066M sensor are presented. Field Programmable Gate Array (FPGA) is used as the main device to accomplish the timing design of the circuits and power driver control of the two sensors. By using the Correlated Double Sampling (CDS) technique  the video noise is reduced and the SNR of the system is increased. A 12- bit A/D converter is used to improve the image quality. The output rate of the imaging system designed with integrated chip can reach to 1.3 frames per second through bi-channel. For its good performance  low power consumption and small volume  the driving system can be applied to aeronautics and astronautics field. With a further improvement  a maximum data output rate of 2.7 frames per second can be reached through all the eight channels of the two CCDs. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Measuring instrument for radial composite deviations of high-precision master gear (EI CONFERENCE) 会议论文  OAI收割
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
作者:  
Zhang Y.;  Wang L.;  Wang L.;  Wang L.
收藏  |  浏览/下载:48/0  |  提交时间:2013/03/25
During double flank rolling composite detection  the radial composite deviations of master gears has been existed and transferred to the measured gear by the primary harmonic curve. In order to improve measurement accuracy  a measuring instrument is developed for radial composite deviations of high-precision master gear in the paper. This instrument uses the structure of spring-suspend swing span to overcome the shortcomings of large rotation errors  low sensitivity  low resolution and large measuring force appearing in the traditional combination-type gear inspection instrument. Artificial intelligence technology is used to improve the efficiency and accuracy of this instrument. The result is that the measuring apparatus is able to meet the requirement and improve efficiency through the measuring experiments on master gears of precision grade 2 with modulus 2 mm and 3 mm  respectively. 2010 SPIE.  
Design of high-resolution fourier transform lens (EI CONFERENCE) 会议论文  OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Advanced Optical Manufacturing Technologies, July 8, 2007 - July 12, 2007, Chengdu, China
作者:  
Zhang L.;  Zhang L.
收藏  |  浏览/下载:30/0  |  提交时间:2013/03/25
With the development of optical information processing  high-resolution Fourier transform lens has often been used in holographic data storage system  spatial filtering and observation of particles. This paper studies the optical design method of high-resolution Fourier transform optical lenses system  which could be used in particles observation and holographic data storage system. According to Fourier transform relation between object and its frequency plane and the theory of geometrical optics  the system with working wavelength 532nm and resolution 3 m was designed based on ZEMAX. A multi-configuration method was adopted to optimize the system's lenses. In the optical system  a diaphragm was placed at the system's spectrum plane and the system demanded a low vacuum to cut down the influences of atmosphere and other particles. The result of finite element analysis indicated that the influences of vacuum pumping to optics spacing and mirror surface shape very minor  and the imaging quality not being affected. This system has many advantages  such as simple structure  good image quality and a high resolution of 3 m. So it has a wide application prospect and can be used both in holographic data storage system and particles observation.  
Research on the affect of differential-images technique to the resolution of infrared spatial camera (EI CONFERENCE) 会议论文  OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, July 8, 2007 - July 12, 2007, Chengdu, China
Jin G.; An Y.; Qi Y.; Hu F.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
The optical system of infrared spatial camera adopts bigger relative aperture and bigger pixel size on focal plane element. These make the system have bulky volume and low resolution. The potential of the optical systems can not be exerted adequately. So  one method for improving resolution of infrared spatial camera based on multi-frame difference-images is introduced in the dissertation. The method uses more than one detectors to acquire several difference images  and then reconstructs a new high-resolution image from these images through the relationship of pixel grey value. The technique of difference-images that uses more than two detectors is researched  and it can improve the resolution 2.5 times in theory. The relationship of pixel grey value between low-resolution difference-images and high-resolution image is found by analyzing the energy of CCD sampling  a general relationship between the enhanced times of the resolution of the detected figure with differential method and the least count of CCD that will be used to detect figure is given. Based on the research of theory  the implementation process of utilizing difference-images technique to improve the resolution of the figure was simulated used Matlab software by taking a personality image as the object  and the software can output the result as an image. The result gotten from the works we have finished proves that the technique is available in high-resolution image reconstruction. The resolution of infrared spatial camera can be improved evidently when holding the size of optical structure or using big size detector by applying for difference image technique. So the technique has a high value in optical remote fields.  
Low resolution structure of integral membrane protein light-harvesting complex LH2 from photosynthetic bacteria in the detergent solution by synchrotron small-angle X-ray scattering 期刊论文  OAI收割
HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 卷号: 27, 页码: #REF!
作者:  
Hong XG(洪新国);  Hong, XG;  Weng, YX;  Li, M
收藏  |  浏览/下载:22/0  |  提交时间:2016/04/11