中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
地质与地球物理研究所 [1]
近代物理研究所 [1]
采集方式
OAI收割 [4]
内容类型
会议论文 [2]
期刊论文 [2]
发表日期
2023 [1]
2011 [1]
2008 [1]
2003 [1]
学科主题
筛选
浏览/检索结果:
共4条,第1-4条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Zinc Isotope Measurement by MC-ICP-MS in Geological Certified Reference Materials
期刊论文
OAI收割
GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2023, 页码: 14
作者:
Wang, Jing
;
Tang, Dong-Mei
;
Yuan, Qing-Han
;
Su, Ben-Xun
;
Li, Wen-Jun
  |  
收藏
  |  
浏览/下载:21/0
  |  
提交时间:2024/01/02
zinc isotopes
MC-ICP-MS
low-resolution mode
standard-sample bracketing
geological certified reference materials
Simulation and experiment of the static FTIR based on micro multi-step mirrors (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Sensor and Micromachined Optical Device Technologies, May 24, 2011 - May 26, 2011, Beijing, China
作者:
Liang Z.-Z.
;
Zhang J.
;
Zhang J.
;
Zhang J.
;
Zhu W.-B.
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/03/25
In recent years
Fourier transform spectrometer (FTS) with small size and low mass is required in many applications with growing need for real-time and small platform spectral detection. In this paper
a micro Fourier transform infrared spectrometer (FTIR) based on spatial modulation mode was designed. This spectrometer has the advantages of high stability and simplified configuration. It also promises optical path differences (OPD) with high precision
as MOEMS technology is used in manufacturing the key components. The simulation and the experiments with regard to this FTIR configuration have been done. Firstly
the diffraction effect of the micro multi-step mirrors (MMSMs) is studied. We discuss the influence to the reversed spectrum by different mirror widths and different diffraction distances. Secondly
we simulate and analyze the influence of the source solid angle to the spectral resolution. Thirdly
we set up the theoretical model of the collimation error which is mainly from the defocus of the optical system and analyze the result caused by the collimation error. Fourthly
a new discrete Fourier transform arithmetic using least-squares cosines progression (LSCP) is proposed which can reconstruct the spectrum with nonuniform sampled signals. Finally
the MMSMs are fabricated used the MOEMS technology and the structural parameters are tested. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Annular sub-aperture stitching interferometry for testing of large asphreical surfaces (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging, ISPDI 2007: Optoelectronic System Design, Manufacturing, and Testings, September 9, 2007 - September 12, 2007, Beijing, China
作者:
Zheng L.-G.
;
Zhang X.-J.
;
Deng W.-J.
;
Wang X.-K.
收藏
  |  
浏览/下载:78/0
  |  
提交时间:2013/03/25
Annular subaperture stitching interferometric technology can test large-aperture
and the PV and RMS of residual error of the full aperture phase distribution is 0.027 and 0.0023
high numerical aperture aspheric surfaces with high resolution
the relative error of PV and RMS is -0.53% and -0.31%
respectively. The results conclude that this splicing model and algorithm are accurate and feasible. So it provides another quantitive measurement for test aspheric surfaces especially for large aperture aspheres besides null-compensation.
low cost and high efficiency without auxiliary null optics. In this paper
the basic principle and theory of the stitching method are introduced
the reasonable mathematical model and effective splicing algorithm are established based on simultaneous least-squares method and Zernike polynomial fitting. The translation errors are eliminated from each subaperture through the synthetical optimization stitching mode
it keeps the error from transmitting and accumulating. The numerical simulations have been carried on by this method. As results
the surface map of the full aperture after stitching is consistent to the input surface map
the difference of PV error and RMS error between them is -0.0074 and -0.00052 ( is 632.8nm)
respectively
Development of low pressure position sensitive multiwire proportional chamber
期刊论文
OAI收割
HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 卷号: 27, 页码: 1023-1026
作者:
Zhang, BG
;
Wen, WX
;
Wei, ZY
;
Zhang, JX
;
Feng, Y
  |  
收藏
  |  
浏览/下载:15/0
  |  
提交时间:2018/05/31
low pressure multiwire proportional chamber
position resolution
delay line readout mode
position determination efficiency