生物质成型燃料压缩机理的国内外研究现状
期刊论文
OAI收割
新能源进展, 2017, 卷号: 5, 期号: 4, 页码: 286-293
作者:
李伟振
;
姜洋
;
阴秀丽
  |  
收藏
  |  
浏览/下载:51/0
  |  
提交时间:2018/12/21
生物质成型燃料
压缩机理
木质素
成型参数
研究现状
biomass molding fuel
compression mechanism
lignin
molding parameters
research situation
Determination of optimum process parameters in gas-assisted injection molding (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electrical Information and Mechatronics, ICEIM2011, December 23, 2011 - December 25, 2011, Jiaozuo, China
Zi K.
;
Chen L.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
With finite element analysis software Moldflow
numerical simulation and studies about FM truck roof handle were conducted on gas-assisted injection molding process. The influences of melt pre-injection shot
gas pressure
delay time and melt temperature were observed by using multi-factor orthogonal experimental method. According to the analysis of the factors' impact on evaluation index
the optimized parameter combination is obtained. Therefore the optimization design of technological parameters is done. The results show that during the gas-assisted injection molding
optimum pre-injection shot is 94%
gas pressure is 15MPa
delay time is 0.5s
melt temperature is 240 C. This study provided a more practical approach for the gas-assisted injection molding process optimization.
The study on the epoxy resin compound X-ray refractive lens (EI CONFERENCE)
会议论文
OAI收割
ICO20: MEMS, MOEMS, and NEMS, August 21, 2005 - August 26, 2005, Changchun, China
作者:
Wang W.
;
Zhang J.
;
Zhang J.
;
Zhang J.
;
Wang W.
收藏
  |  
浏览/下载:32/0
  |  
提交时间:2013/03/25
In this paper
the authors report their resent results of the study on the epoxy resin compound X-ray refractive lens. At the first
the theoretical results of the structure parameters for such a device are given. Then
the fabrication technologies are presented. They are deep soft X-ray lithography
mold-manufacturing and molding. The material of X-ray photoresist is PMMA
the mold is made of silicone rubber
and the material of the lens is epoxy resin. Some measured results by means of optical microscope and SEM are also shown. The structure height of the epoxy resin compound lens is measured to be 500 micrometers.