中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
合肥物质科学研究院 [1]
国家授时中心 [1]
采集方式
OAI收割 [4]
内容类型
会议论文 [2]
期刊论文 [2]
发表日期
2018 [1]
2014 [1]
2013 [1]
2007 [1]
学科主题
筛选
浏览/检索结果:
共4条,第1-4条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Study of time link calibration based on GPS carrier phase observation
期刊论文
OAI收割
IET RADAR SONAR AND NAVIGATION, 2018, 卷号: 12, 期号: 11, 页码: 1330-1335
作者:
Zhang, Pengfei
;
Tu, Rui
;
Gao, Yuping
;
Guang, Wei
;
Zhang, Rui
  |  
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2021/11/29
Global Positioning System
clocks
calibration
GPS carrier phase observation
time link calibration
precise time transfer solution software
zero baseline time link
long distance baseline time link experiment
Global Positioning System
root mean square value
national time service centre
NTSC
Influence of the observation distance on the lightning channel temperature studied by means of spectroscopic diagnosis
期刊论文
OAI收割
ACTA PHYSICA SINICA, 2014, 卷号: 63
-
  |  
收藏
  |  
浏览/下载:10/0
  |  
提交时间:2020/10/26
PEAK TEMPERATURE
SPECTRA
STROKE
lightning spectra
observation distance
channel temperature
Beer-Lambert law
Advanced astigmatism-corrected tandem Wadsworth mounting for small-scale spectral broadband imaging spectrometer (EI CONFERENCE)
会议论文
OAI收割
作者:
Lin G.-Y.
收藏
  |  
浏览/下载:38/0
  |  
提交时间:2013/03/25
Tandem gratings of double-dispersion mount make it possible to design an imaging spectrometer for the weak light observation with high spatial resolution
high spectral resolution
and high optical transmission efficiency. The traditional tandem Wadsworth mounting is originally designed to match the coaxial telescope and large-scale imaging spectrometer. When it is used to connect the off-axis telescope such as off-axis parabolic mirror
it presents lower imaging quality than to connect the coaxial telescope. It may also introduce interference among the detector and the optical elements as it is applied to the short focal length and small-scale spectrometer in a close volume by satellite. An advanced tandem Wadsworth mounting has been investigated to deal with the situation. The Wadsworth astigmatism-corrected mounting condition for which is expressed as the distance between the second concave grating and the imaging plane is calculated. Then the optimum arrangement for the first plane grating and the second concave grating
which make the anterior Wadsworth condition fulfilling each wavelength
is analyzed by the geometric and first order differential calculation. These two arrangements comprise the advanced Wadsworth mounting condition. The spectral resolution has also been calculated by these conditions. An example designed by the optimum theory proves that the advanced tandem Wadsworth mounting performs excellently in spectral broadband. 2012 Optical Society of America.
The synthesis and field emission property of carbon nanotubes on carbon fibers substrate (EI CONFERENCE)
会议论文
OAI收割
Technical Digest of the 20th International Vacuum Nanoelectronics Conference, IVNC 07, July 8, 2008 - July 12, 2008, Chicago, IL, United states
Leyong Z.
;
Weibiao W.
;
Jingqiu L.
;
Yuxue X.
;
Da L.
;
Song C.
;
Haifeng Z.
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2013/03/25
Using ferrocene as catalyst precursor
C2H2 as carbon source
carbon nanotubes (CNTs) with uniform density were synthesized on carbon fibers substrate by floating catalyst method. The morphology and microstructure were characterized by field emission scanning electron microscope (FESEM) and high-resolution transmission electron microscopy (HRTEM). The observation showed that the length of CNTs is about 2 m
the average space between adjacent CNTs is about 300 nm and the diameter of CNT is about 45 nm. The less dense "short and stubby" aligned CNTs films should have good electron field emission characteristics. The results of field emission showed that the emission current of CNTs/carbon fibers was 5 A at the field of 2.5 V/m
and the emission current can be 280 A with a field of 7 V/m (the specimen area is 0.25 cm2 and the distance between cathode and anode is 200 m). The calculation based on the F-N plot indicated that the field enhancement factor of CNTs tip is 499122. Using the conductivity and chemical stability of carbon fibers and the uniform and sparse density distribution of CNTs on carbon fibers substrate
the tip predominance of carbon nanotubes can be exerted
and simultaneously the effect of screening effects between adjacent carbon nanotubes on the field emission performance can also be effectively decreased. The CNTs synthesized on carbon fibers substrate has many predominances for the fabrication of cold cathode devices. For example
using the removability of carbon fibers
the cathode of CNTs/carbon fibers can be arbitrarily moved
enlaced or combined to form different patterns
and the cathode of CNTs/carbon fibers can be also fabricated in large size. Therefore
CNTs/carbon fibers may have potential application in field emission displays.