中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共5条,第1-5条 帮助

条数/页: 排序方式:
Researchon the Selection of Mars Onboard Laser Induced Breakdown Spectrometer (MarsCoDe) Calibration Samples 期刊论文  OAI收割
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 卷号: 39, 期号: 5, 页码: 1623-1629
作者:  
Cai Ting-ni;  Li Chun-lai;  Ren Xin;  Liu Bin;  Liu Da-wei
  |  收藏  |  浏览/下载:16/0  |  提交时间:2020/03/10
Validation of HJ-1B Thermal Infrared Channels Onboard Radiometric Calibration Based on Spectral Response Differences SCI/SSCI论文  OAI收割
2014
Liu L.; Fu Q. Y.; Shi T. T.; Wang A. C.; Zhang X. W.
收藏  |  浏览/下载:30/0  |  提交时间:2014/12/24
Level 0 and level 1 data processing for a type of hyper-spectral imager (EI CONFERENCE) 会议论文  OAI收割
2009 International Conference on Optical Instruments and Technology, OIT 2009, October 19, 2009 - October 21, 2009, Shanghai, China
Li X.; Yan C.
收藏  |  浏览/下载:73/0  |  提交时间:2013/03/25
Hyper-spectral imaging (HSI) is a kind of optical remote sensor that can simultaneously obtain spatial and spectral information of ground targets. We are now designing a data processing system for a type of space-borne push-broom HSI  then it performs radiometric and spectral calibration based on the ground calibration results and onboard calibration collection. The detailed algorithms for bad pixel replacement  which has 128 spectral channels covering the spectral range from 400nm to 2500nm. With its large amount of spectral channels  radiometric and spectral calibration were presented. After processing  the HSI collects large volume of spectral imaging data need to be efficiently and accurately processed and calibrated. In this paper  the digital numbers downlinked from the spacecraft can be converted into at-sensor absolute spectral radiance of ground targets  the detailed Level 0 and Level 1 data processing steps for the HSI were presented. The Level 0 processing refers to a set of tasks performed on the data downlinked from the spacecraft  thus providing accurate quantified spectral imaging data for various applications. 2009 SPIE.  including decoding to extract science data  separating the science data into files corresponding to different tasks (e.g. ground imaging  dark imaging  and onboard calibration)  checking data integrity and instrument settings  data format conversion  and Level 0 files creation. The Level 1 processing performs several steps on Level 0 data. Firstly  it corrects the image artifacts (mostly the SWIR smear effect)  subtracts the dark background  and performs the bad pixel replacement according to the prelaunch measurement  
一种消除全极化微波辐射计顺/逆风向遥感模糊性的新方案——星上定标和扫描机制设计的有关考虑(英文) 期刊论文  OAI收割
遥感学报, 2009, 卷号: 13, 期号: 2, 页码: 190-196
王振占; 刘璟怡; 殷晓斌; 姜景山
收藏  |  浏览/下载:26/0  |  提交时间:2014/05/04
The Simulation measurement experiment and calibration for Solar Total Irradiance Monitor on board (EI CONFERENCE) 会议论文  OAI收割
ICO20: Remote Sensing and Infrared Devices and Systems, August 21, 2005 - August 26, 2005, Changchun, China
Yupeng W.; Wei F.; Bingxi Y.
收藏  |  浏览/下载:37/0  |  提交时间:2013/03/25
STIM (Solar Total Irradiance Monitor) can be used on sun-synchronous polar orbit weather satellites to measure the total solar irradiance. It contains three independent and identical wide view absolute radiometers. They are mounted on the satellite in an angle which ensure the sun scan over the field of view of the absolute radiometers. This measurement method doesn't need the instrument tracking the sun but the sun scan over the field of view of the absolute radiometers in each orbit cycle. The paper presents the measurement method of simulation for solar irradiance measurement and calibration by mounting the instrument on a two-axis rotation table. By controlling the rotation angle velocity of the instrument in the meridian direction being the same as that of the weather satellite's on orbit  we can measure the solar irradiance when the sun scan over the field of view of the absolute radiometers to simulate the onboard state. And we have operated the measurement with the prototype of STIM. The SIAR-1 is traceable to WRR and serves as a transfer standard. So simultaneous comparison measurements between SIAR-1 and each of the three wide view absolute radiometers are measured to provide calibration corrections to the instrument. And we have a further study at the influence of stray light to the measurement results. This paper presents the method of simulation experiment and calibration for solar irradiance measurement with Solar Total Irradiance Monitor on board.