中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
金属研究所 [1]
福建物质结构研究所 [1]
采集方式
OAI收割 [4]
内容类型
会议论文 [2]
期刊论文 [2]
发表日期
2011 [1]
2010 [1]
2008 [2]
学科主题
筛选
浏览/检索结果:
共4条,第1-4条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
作者升序
作者降序
The angular velocity estimation principal of -- filter based on high sampling rate (EI CONFERENCE)
会议论文
OAI收割
2011 2nd International Conference on Mechanic Automation and Control Engineering, MACE 2011, July 15, 2011 - July 17, 2011, Inner Mongolia, China
作者:
Zhang Y.
收藏
  |  
浏览/下载:34/0
  |  
提交时间:2013/03/25
In order to get angular velocity of stabilization servo mechanism from angular position sensors
-- filter and its angular velocity transfer function were predigested. Combing with optimum parameters
-- filter based on high sampling rate was established
the effect of and sample rate on filter nature frequency were evaluated. According to the requirements of stabilization platform
the principle of steady and transient tracking filter differential were proved. With the hypothesis of constant acceleration
the frequency characteristics of angular velocity transfer function were analyzed
three-dimensional Kalman filter was simplified
and the filter parameters were designed. The results show that when the spectrum of input signal was lower than 6rad/s
parameters was 0.02
and sampling period were 0.08ms and 0.1ms respectively
the filter can realize differential exactly
when the spectrum was 9rad/s
the precision was no less than 1.1%
the phase leading of angular position was no less than 70
the natural frequency should be higher than the cut-off frequency of stabilization platform was two or three times. In the engineering of electro-optical stabilization servo mechanism
-- filter has properties of tracking differential
and reached the requirement of platform angular velocity estimation. Also it is one of the effective methods to get angular velocity from angular position sensors. 2011 IEEE.
Spectroscopy and Energy Transfer in Yb3+ and Tm3+ Co-doped Gd3Ga5O12 Crystal
期刊论文
OAI收割
Chinese Journal of Structural Chemistry, 2010, 卷号: 29, 期号: 3, 页码: 449-458
G. T. Chen, H. Zhou, W. C. Lv, Y. Wang, Z. Y. You, J. F. Li, Z. J. Zhu and C. Tu
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2012/11/02
Yb3+/Tm3+ co-doped Gd3Ga5O12 crystal
Judd-Ofelt (J-O) theory
spectrum
characteristics
energy transfer
rare-earth ions
judd-ofelt analysis
optical characterization
absorption intensities
spectral properties
mu-m
laser
ho3+
fluorescence
garnets
Preparation and optical spectrum characteristics of BaHfO3 : Ce nano-powder
期刊论文
OAI收割
ACTA METALLURGICA SINICA, 2008, 卷号: 44, 期号: 3, 页码: 381-384
作者:
Liu Jing
;
Ma Weimin
;
Wen Lei
;
Li Xikun
;
Shen Shifei
  |  
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2021/02/02
scintillantor
BaHfO3 : Ce
nano-powder
co-deposition
optical spectrum characteristics
Temperature characteristics of high power vertical cavity surface emitting lasers (EI CONFERENCE)
会议论文
OAI收割
Semiconductor Lasers and Applications III, November 12, 2007 - November 13, 2007, Beijing, China
作者:
Qin L.
收藏
  |  
浏览/下载:32/0
  |  
提交时间:2013/03/25
By using oxidation confinement technology high power vertical-cavity surface-emitting lasers are fabricated in experiment. The electrical and optical performance characteristics such as threshold current
efficiency
emission wavelength
and output power are measured under continuous wave (CW) condition at room temperature. The maximum output power is up to watt regime at wavelength of about 980nm. The temperature characteristics of the device are investigated experimentally in detail. The variation in lasing threshold current with temperature is studied. The characteristic temperature T0 of the device is derived
and the value is about 211K. Such a high characteristic temperature T0 of threshold current can lead to good temperature sensitivity of the device. At the same time
the lasing spectrum characteristics with temperature are also measured. The wavelength shift with temperature is just about 0.06nm/K. From the measured results
it is shown that the device can still operate at high temperature condition.