中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
西安光学精密机械研究... [1]
采集方式
OAI收割 [3]
内容类型
会议论文 [3]
发表日期
2019 [1]
2011 [1]
2007 [1]
学科主题
筛选
浏览/检索结果:
共3条,第1-3条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
作者升序
作者降序
Optical system design and measurement precision analysis of pointing mirror in solar hard x-ray imager
会议论文
OAI收割
Beijing, China, 2019-07-07
作者:
Zhao, Jin
;
Yang, Jianfeng
;
He, Yinghong
;
Liu, Shengrun
  |  
收藏
  |  
浏览/下载:238/0
  |  
提交时间:2020/03/04
solar hard X-ray imager
pointing mirror
optical system
ghost analysis
Design and test of pointing mirror assembly for spaceborne remote sensing camera (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electronics, Communications and Control, ICECC 2011, September 9, 2011 - September 11, 2011, Ningbo, China
作者:
Chen W.
收藏
  |  
浏览/下载:40/0
  |  
提交时间:2013/03/25
In order to ensure the surface figure of the pointing mirror (460mm long
290mm wide) in spaceborne remote sensing camera
Silicon Carbide was selected as the mirror material. The form of composite triangular and rectangular and the combination of open and closed back was explored in the lightweight design. A new kinematic mount and flexible structure in axis is used to hold the mirror around the lateral surface. The structure can minimize distortions induced by coefficient of thermal expansion mismatch among the materials. This eliminates the bending of the integral mount under the weight of the mirror. Optical performance of the mirror was analyzed under gravity load and temperature load using finite element method. Predicted surface figure error based on the removal of bias
tilt and power was calculated using an in-house Matlab script for mirrors. The pointing mirror assembly was tested using open loop servo control. And the surface figure was checked using interferometer. Surface figure accuracy is better than 1/30 ( 632.8nm
rms). The results show that the kinematic mount induces minimal figure error on the optical surface. 2011 IEEE.
Research on 10.6 m laser beam monitoring in CO2 laser processing system (EI CONFERENCE)
会议论文
OAI收割
Infrared Materials, Devices, and Applications, November 12, 2007 - November 15, 2007, Beijing, China
作者:
Gao Y.
;
Shao S.
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2013/03/25
It is a key point of CO2 laser beam monitoring in the CO 2 laser processing system to achieve alignment between CO2 laser and PL (pointing and launching) system. By monitoring the angle offset of CO2 laser beam
the compensation can be gotten witch is given to fast-steering mirror to rectify the direction of laser beam. But the normal photoelectric detector can not get the laser signal because of CO2 laser's high energy and long wavelength. Its wavelength is 10.6m and its power can reach kW level. Consequently
it is difficult to detect the high-energy 10.6m laser beam directly. So
we monitored the output mirror of laser resonator superseded the laser beam
indirectly. The laser beam monitoring system could be designed based on CCD laser auto-collimation angular measurement principle and image processing method. In this paper
application of CCD laser auto-collimation angular measurement principle and image processing method for CO2 laser beam monitoring system is introduced particularly
After design
fabrication and alignment
the monitoring system can be used for experimental study that including angular measurement accuracy and angle offset measurement of CO2 laser beam. Angle offset range and angle variation rule of CO2 laser beam is also can be acquired for further research.