A shared augmented virtual environment for real-time mixed reality applications
期刊论文
OAI收割
COMPUTER ANIMATION AND VIRTUAL WORLDS, 2018, 卷号: 29, 期号: 5, 页码: 14
作者:
Zhu, Yu
;
Li, Shiying
;
Luo, Xi
;
Zhu, Kang
;
Fu, Qiang
  |  
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2019/12/10
calibration
Kinect
mixed reality
natural image matting
real time
Integral time real-time adjust method based on radiation calibration
期刊论文
OAI收割
JOURNAL OF INFRARED AND MILLIMETER WAVES, 2014, 卷号: 33, 期号: 3, 页码: 297-302
作者:
Li Man-Liang
;
Wu Qin-Zhang
;
Xia Mo
;
Wu Shu-Wen
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2015/07/10
integral time
real-time adjust
radiation calibration
dynamic range
radiation characteristics measurement system
Calibration of pulse transit time through a cable for EAS experiments
期刊论文
OAI收割
CHINESE PHYSICS C, 2014, 卷号: 38, 期号: 6, 页码: 66202
作者:
Qian XL(钱祥利)
;
Chang JF(常劲帆)
;
Feng CY(冯朝阳)
;
Qian, XL
;
Chang, JF
收藏
  |  
浏览/下载:55/0
  |  
提交时间:2016/04/08
EAS experiment
time-walk effect
real-time calibration
transit time
Research of real-time control and calibration on laser energy simulator for optoelectronic confrontation HWIL system (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electronics, Communications and Control, ICECC 2011, September 9, 2011 - September 11, 2011, Ningbo, China
作者:
Wang J.-J.
收藏
  |  
浏览/下载:18/0
  |  
提交时间:2013/03/25
In the paper
real-time control and calibration on laser energy simulator is studied
which is based on Optoelectronic confrontation hardware-in-loop (HWIL) simulation test system. The control of the laser energy is necessary in simulation system
and it is vital to make the test successfully. The laser energy simulator simulates the attenuation process and the changing of laser energy by the continuous rotation of Glan prism. To get high accuracy of laser power outdoor
the accurate calibration of the rotation position and the attenuation process in energy simulator is necessary. We apply dual calibration on the laser energy simulator
and the feasibility was proved by the calibration data. 2011 IEEE.
Non-uniformity correction in multi-CCD imaging system (EI CONFERENCE)
会议论文
OAI收割
2010 2nd International Conference on Mechanical and Electronics Engineering, ICMEE 2010, August 1, 2010 - August 3, 2010, Kyoto, Japan
Tao M.
;
Ren J.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
The non-uniformity phenomenon exists in each channel of multi-CCD imaging systems. The factors which lead to the problem are complex. The conventional calibrating algorithms can not consider all of these factors and have poor effects. According to the characters of multi-CCD imaging systems
a non-uniformity correction method based on the scene was proposed by adopting the traditional two-point correction theories. The correction coefficient of each channel image can be calculated via the linear relation between the two neighboring pixel lines in the two-channel images. Compared with the conventional two-point calibration and multi-point calibration methods
contrastive calibrating results were obtained. This method does not need any standard lighted image as reference source
which provides a real time way for calibrating the multi-CCD imaging systems in practical applications. 2010 IEEE.
Dynamic data fixing for IR target radiation characteristics (EI CONFERENCE)
会议论文
OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Lihua C.
;
Juan C.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
The main methods to measure the target IR features are the following two ways: test and then measurement
or theoretical and simulation calculation. The former is direct measurement so the results are more accurate but the test is costly and complicated
so that it is limited in the application. Theoretical and simulation calculation are widely used in the target IR radiation calibration. Here we give the basic configuration of the calibration platform for measuring the IR radiation of the large area low temperature blackbody source
and discuss the calibration flowchart and key technologies for atmospheric transmission correction. The dynamic data are analyzed in real time to determine the IR radiation features in the data fusion subsystem
and the experimental results show that the calibration method is feasible and practical. 2010 IEEE.
Modeling and analysis of dialyte-lens auto-focusing technology for theodolite (EI CONFERENCE)
会议论文
OAI收割
2008 International Conference on Optical Instruments and Technology: Optoelectronic Measurement Technology and Applications, November 16, 2008 - November 19, 2008, Beijing, China
Wu L.-T.
;
Qiao Y.-F.
;
Wu D.-K.
;
Cai S.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
In order to realize real-time auto-focusing for theodolite
lens-apart method was designed with the corresponding math model built and analyzed. An Object beam splitted after the first image surface of the theodolite traveled through two dialyte lens and then was imaged on CCD. The distance between two spots when exactly focused was set as the calibration value
and the relationship between defocus distance and spot offset was given. The influence of tracking center shift and divergence angle etc. on focusing accuracy was analyzed. Compared with the traditional focusing method
this scheme has a higher accuracy
faster calculation
higher tolerance for environment temperature and a simpler construction. The experiment result exhibited a resolution higher than 0.056mm
which shows a bright engineering application prospect for this method. 2009 SPIE.