IOMMU Para-Virtualization for Efficient and Secure DMA in Virtual Machines
期刊论文
OAI收割
KSII TRANSACTIONS ON INTERNET AND INFORMATION SYSTEMS, 2016, 卷号: 10, 期号: 12, 页码: 5375-5400
作者:
Tang, Hongwei
;
Li, Qiang
;
Feng, Shengzhong
;
Zhao, Xiaofang
;
Jin, Yan
  |  
收藏
  |  
浏览/下载:67/0
  |  
提交时间:2019/12/12
IOMMU virtualization
para-virtualization
DMA security
virtio
simulated device
A servo control system of dynamic target simulation device for aerial camera (EI CONFERENCE)
会议论文
OAI收割
2nd International Conference on Advanced Design and Manufacturing Engineering, ADME 2012, August 16, 2012 - August 18, 2012, Taiyuan, China
作者:
Ji Q.
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2013/03/25
This article introduces a dynamic target simulation device to evaluate dynamic image quality of the aerial camera. The device simulated the positional relationship of the sky and ground in the laboratory when aerial camera flies at high altitude. And it can be used to inspect camera image quality of aerial camera flying at high altitude in laboratory. At a same time
the article focuses on this servo control system of device
building a control model
and giving control strategy. The servo control system was proved stably and reliably after experimental verification. And it provides a strong guarantee for the test of the dynamic image. (2012) Trans Tech Publications
Switzerland.
The design of the data communication and display system based on GeoCOM technology (EI CONFERENCE)
会议论文
OAI收割
2012 5th International Symposium on Computational Intelligence and Design, ISCID 2012, October 28, 2012 - October 29, 2012, Hangzhou, China
Geng T.-W.
;
Wang Z.-Q.
;
Li D.-N.
;
Shen C.-W.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
The system is developed for the real-time data processing. The data include the sensor data from TS02 total station and the data from the CCD processing system. It was introduced that the TS02 total station which produced by the Leica company. The GeoCOM application interface which provided by Leica company for the client to exploit it was introduced. The main controller of the system is C8051F021. The protocol of I2C bus is simulated by software. System works in the timing interrupt way. The angle error is calculated and transferred to remote receive device. All data is displayed on LCD. The hardware and software design method is present. The system has been applied to the angle monitor equipment. The system is stable and reliable in practical application. 2012 IEEE.
Contrast research on interpolation and subpixel imaging in CCD geometric superresolution reconstruction (EI CONFERENCE)
会议论文
OAI收割
1st Asia Pacific Conference on Postgraduate Research in Microelectronics and Electronics, PrimeAsia 2009, November 19, 2009 - November 21, 2009, Shanghai, China
作者:
Xu Y.-S.
;
Yang S.-W.
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2013/03/25
In order to enhance the resolution of Charge Coupled Device (CCD) pixel with the pixel dimension and focal length of optical system unchanged
the problem of CCD geometric superresolution is educed. The problem is discussed in terms of software and hardware. In software
the bicubic interpolation is introduced
while in hardware
the subpixel imaging method is utilized. The subpixel imaging method integrates two uniform linear CCDs staggered by half dimension of pixel in one device. In operation
the line frequency is doubled. At last
the collected data is interweaved to synthesize a high resolution image. The two methods
bicubic interpolation and subpixel imaging
are simulated with Matlab7.0.1. The qualitative and quantitative analyses are given. The simulated results of lanczos and cubic spline interpolation methods are given simultaneously to show the performance of interpolation. The simulation result shows that the result images quality becomes better in both methods
but compared with bicubic interpolation method
the synthesized image PSNR gained from sub-pixel imaging is averagely enhanced by 2.1682dB
while the elapsed time is reduced to be about one forth. The subpixel imaging method could significantly mitigate the image blur introduced by undersample. 2009 IEEE.