中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共5条,第1-5条 帮助

条数/页: 排序方式:
Inverse Fluid-solid Interaction Scattering Problem Using Phased and Phaseless Far Field Data 期刊论文  OAI收割
ACTA MATHEMATICAE APPLICATAE SINICA-ENGLISH SERIES, 2020, 卷号: 36, 期号: 1, 页码: 74-94
作者:  
Ji, Xia;  Jia, Yun-fei;  Liu, Xiao-dong
  |  收藏  |  浏览/下载:22/0  |  提交时间:2020/05/24
Direct Determination of Lead in Foods by Solid Sampling Electrothermal Vaporization Atomic Fluorescence Spectrometry 期刊论文  OAI收割
ANALYTICAL SCIENCES, 2016, 卷号: 32, 期号: 9, 页码: 1007-1010
作者:  
Shang, Derong;  Zhao, Yanfang;  Zhai, Yuxiu;  Ning, Jinsong;  Duan, Delin
收藏  |  浏览/下载:24/0  |  提交时间:2016/11/22
Recent developments in solid-phase microextraction for on-site sampling and sample preparation 期刊论文  OAI收割
trac-trends in analytical chemistry, 2011, 卷号: 30, 期号: 10, 页码: 1568-1574
作者:  
Duan, Chunfeng;  Shen, Zheng;  Wu, Dapeng;  Guan, Yafeng
收藏  |  浏览/下载:19/0  |  提交时间:2012/07/09
A high-accuracy parameter estimation algorithm for jointless Frequency-shift track circuit (EI CONFERENCE) 会议论文  OAI收割
ISECS International Colloquium on Computing, Communication, Control, and Management, CCCM 2008, August 3, 2008 - August 4, 2008, Guangzhou, China
作者:  
Zheng X.
收藏  |  浏览/下载:24/0  |  提交时间:2013/03/25
FSK (Frequency Shift keying) signal  which has advantages of narrow-bandwidth  strong anti-interference ability  long transmission distance and so on  is used in jointless Frequency-shift track circuit to send different kinds of control signals. However  as FSK is non-linearly modulated  parameter estimation with high accuracy is hard to realize. Based on the spectrum analysis complement with time-frequency distribution  a highaccuracy FSK signal parameter estimation algorithm is put forward in this paper. According to the signal characteristics  under-sampling and ZFFT are used to improve the accuracy of spectrum analysis  and the base frequency resolution meets system requirement of 0.02Hz. Wigner-Ville distribution has an excellent time-frequency concentration while serious cross-term interference at the same time. Through the design of kernel function  the cross-terms are almost suppressed and the upper/down side frequency resolution meets the system requirement of 0.2Hz. The effectivities of all the methods mentioned above have been proved by MATLAB simulation  which pave a solid way for the development of high-accuracy FSK signal parameter estimation devices. 2008 IEEE.  
SPME-GC-MSD for determination of nine phenyl compounds in snow water in Beijing China 期刊论文  OAI收割
CHROMATOGRAPHIA, 2005, 卷号: 62, 期号: 2015-01-02, 页码: 109-111
作者:  
Zhou, S;  Huang, JX;  Gao, X;  Zhao, LW
收藏  |  浏览/下载:18/0  |  提交时间:2015/10/28