中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
采集方式
OAI收割 [2]
内容类型
会议论文 [2]
发表日期
2011 [1]
2005 [1]
学科主题
筛选
浏览/检索结果:
共2条,第1-2条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Study on spectrograph for ionosphere: A broadband imaging instrument prototype for far-ultraviolet (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:
Wang S.-R.
;
Lin G.-Y.
;
Yu L.
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2013/03/25
Current research on space-based exploration for the ionosphere needs more advanced technologies. Because the spectral signals in the ionosphere distributing basically in the far-ultraviolet waveband are very weak. Usual spectrometer structures and detectors such as CCD can't receive enough information. Based on this principle of atmospheric sounding
the imaging spectrometer prototype for ionosphere detection application was designed to solve the problem. This prototype consists of the telescope and the imaging spectrometer. The simple structure and small number of mirrors can help higher transmission efficiency be achieved and weak signals detection be implemented. The telescope is an off-axis parabolic mirror and the spectrometer is a modified Czerny-Turner spectral imaging system. Modified Czerny-Turner spectrometer contains a spherical mirror
a fixed plane grating and a toroidal mirror. By adjusting the incident angle to the collimating mirror and using toroidal mirror
coma and astigmatism were corrected well. We also optimize distances between the grating to the focusing mirror and the focusing mirror to the image plane to improve disadvantages of traditional Czerny-Turner structure. Designed results demonstrate that aberrations are substantially corrected
and high image quality can be obtained in broad waveband. The photon counting Wedge-Strip-Anode detector with micro-channel planes as the receiving plane is accepted for the instrument prototype. The other photon counting 2-D detector responding well for weak light such as Cross-Delay line detector and MAMA detector can also be used for detection. The calibration and performances testing system is made of a vacuum system
a deuterium lamp
a monochrometer and the instrument prototype. Results obtained from the experiment show that the spectral resolution is 2.4 nm and the spatial resolution is 80 m. The other calibration experiments are running. The technology of the spectrometer prototype is important for the research and applications of ionosphere remote sensing. 2011 SPIE.
Imaging quality analysis of KBA x-ray microscope working at grazing incidence (EI CONFERENCE)
会议论文
OAI收割
Optical Design and Testing II, November 8, 2004 - November 11, 2004, Beijing, United states
作者:
Zhao L.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
In the latest 20 years
x-ray imaging technology has developed fast in order to meet the need of x-ray photo-etching
spatial exploration technology
high-energy physics
procedure diagnosis of inertial confinement fusion (ICF) et al. Since refractive index of materials in the x-ray region is lower than 1
and x-ray is strongly absorbed by materials
it is very difficult to image objects in the x-ray region. Conventional imaging methods are hardly suitable to x-ray range. In general
grazing reflective imaging and coding aperture imaging methods have been adopted more and more. In this paper
according to user's requirement
we have designed a non-coaxial grazing KBA microscope. The microscope consists of two sets of perpendicular spherical mirrors
each set includes two parallel mirrors. Taking it as an example
we have compiled an optical computing program for the non-coaxial grazing imaging systems so as to analyze and evaluate aberrations of KBA microscope. Thus it can help us to get an optimal comprehension of KBA x-ray imaging system. In the same time
the analytical results provide reliable foundation for evaluating imaging quality of KBA microscope.