中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
力学研究所 [1]
长春光学精密机械与物... [1]
近代物理研究所 [1]
采集方式
OAI收割 [3]
内容类型
期刊论文 [2]
会议论文 [1]
发表日期
2022 [1]
2016 [1]
2010 [1]
学科主题
筛选
浏览/检索结果:
共3条,第1-3条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
SPATIAL STRUCTURE AND DROPLET DISTRIBUTION OF ATOMIZATION BY THREE CIRCULARLY ARRANGED IMPINGING JETS
期刊论文
OAI收割
ATOMIZATION AND SPRAYS, 2022, 卷号: 32, 期号: 6, 页码: 29-49
作者:
Hou L(侯林)
;
Zhang DW(张大伟)
;
Fan XJ(范学军)
;
Fan XJ(范学军)
  |  
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2022/08/10
impinging jets
droplet distribution
SMD
spatial uniformity
mis-aligned impact
Non-uniformity effects of the inter-foil distance on GEM detector performance
期刊论文
OAI收割
CHINESE PHYSICS C, 2016, 卷号: 40, 页码: 6
作者:
Huang, Yan
;
Duan, Li-Min
;
Zhang, Yan
;
Li, Hong-Jie
;
Wang, Ren-Sheng
  |  
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2018/05/31
gaseous electron multiplication
non-uniformity effects
spatial resolution
Research on radiometric calibration of interline transfer CCD camera based on TDI working mode (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Liu J.-G.
;
Wu X.-X.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
Interline transfer CCD camera can be designed to work in time delay and integration mode similar to TDI CCD to obtain higher responsivity and spatial resolution under poor illumination condition. However it was found that outputs of some pixels were much lower than others' as interline transfer CCD camera work in TDI mode in laboratory radiometric calibration experiments. As a result photo response non-uniformity(PRNU) and signal noise ratio(SNR) of the system turned for the worse. This phenomenon's mechanism was analyzed and improved PRNU and SNR algorithms of interline transfer CCD camera were advanced to solve this problem. In this way TDI stage was used as a variant in PRNU and SNR algorithms and system performance was improved observably with few influences on use. In validation experiments the improved algorithms was applied in radiometric calibration of a camera with KAI-0340s as detector. Results of validation experiments proved that the improved algorithms could effectively improve SNR and lower PRNU of the system. At the same time characteristic of the system could be reflected better. As working in 16 TDI stages
PRUN was reduced from 2.25% to 0.82% and SNR was improved about 2%. 2010 Copyright SPIE - The International Society for Optical Engineering.