中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
武汉岩土力学研究所 [1]
采集方式
OAI收割 [3]
内容类型
会议论文 [3]
发表日期
2013 [1]
2010 [1]
2007 [1]
学科主题
筛选
浏览/检索结果:
共3条,第1-3条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Failure Characteristics and Support Optimal Design of Columnar Jointed Rock Mass at a Diversion Tunnel
会议论文
OAI收割
Jinan, PEOPLES R CHINA, MAY 24-26, 2013
作者:
Zhu, Xiangdong
;
Hu, Lianxing
;
Jiang, Quan
;
Li, Shaojun
;
Li, Jun
  |  
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2018/06/05
failure characteristics
support optimal design
columnar jointed rock mass
excavation unloading
Optimal design of strap-down inertial navigation support under random loads (EI CONFERENCE)
会议论文
OAI收割
2010 IEEE International Conference on Information and Automation, ICIA 2010, June 20, 2010 - June 23, 2010, Harbin, Heilongjiang, China
作者:
Li M.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
In order to realize miniaturization and light weight of the strap-down inertial navigation system
and then to make sure that it works well under random loads
optimal design is applied to the strap-down inertial navigation support with the methods of topology optimization and size optimization. Firstly
based on the installation requirement of devices and connection requirement of the support and the carrier
the initial structure of the support is designed. Topology optimization with FEA software ANSYS is adopted on the initial structure to get the basic one. Then 5 critical sizes are chosen as design variables
and the support structure is optimized by means of size optimization to reach light weight with satisfying the requirement of dynamic stiffness. Finally
random vibration analysis is applied to the initial structure. In the mean time
random vibration test is carried out to qualify the analysis method. After the qualification
a random vibration analysis is applied to the optimized support structure to get the rms of displacement response and acceleration response of the support to validate whether the optimized structure is appropriate. The results indicate that the dynamic stiffness of the optimized support structure satisfies the design requirements
and its weight is lighter 49.38% than that of the initial one. This research can be a reference to the structure design of supports under random loads
and the result has been applied to the development and manufacture of a prototype aerocraft. 2010 IEEE.
Design and analysis of large spaceborne light-weighted primary mirror and its support system (EI CONFERENCE)
会议论文
OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Large Mirrors and Telescopes, July 8, 2007 - July 12, 2007, Chengdu, China
Yan Y.
;
Jin G.
;
Yang H.-B.
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2013/03/25
With the development of the resolution of spaceborne remote sensor
the diameter of the primary mirror of spaceborne telescope becomes larger and larger. The distortion of primary mirror which is influenced by the mirror material
structure
self-weight
support system and temperature environment affects optical image quality finally. In this paper
an on-axis TMA high-resolution Cassegrain optical payload with a primary mirror whose diameter is 650mm was designed and the effects of the influence factors of the distortion acts on the on-axis TMA optical system primary mirror had been analyzed by means of Finite Element Analysis. During work
the technology of the primary mirror design had been summarized and general consideration of the primary mirror design technology also had been described at the same time. Considering the telescope manufacture and work station
a reasonable and optimal structure of the primary mirror sub-assembly is taken finally. In the end
the distortion of the primary mirror during its fabrication station and work station had been analyzed by integrated Finite Element Analysis Method. The results implicated the synthesis profile error (P-V value) for the primary mirror is less than /10 and all the indexes of the primary mirror satisfy the requirements of the optical system.